97 resultados para Electrical dipoles


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Periodically loaded dipole arrays printed on grounded dielectric substrate are shown to exhibit left-handed propagation properties. In an equivalent transmission line representation, lefthandedness emerges due to the excess series capacitance and shunt inductance. Based on this concept, the authors study the distribution of the modal fields and the variation of series capacitance and shunt inductance as the dipoles are loaded with stubs. Full wave dispersion curves that show the gradual transition from a right-handed to a left-handed medium upon periodically loading the dipoles with stubs are presented. An equivalent circuit is derived that matches to a very good extent the full wave result. The cell dimensions are a small fraction of the wavelength (),15), so the structure can be considered as an equivalent homogeneous surface. The structure is simple, readily scalable to higher frequencies and compatible with low-cost fabrication techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrical conductivities of 1-alkyl-3-methylimidazolium tetrafluoroborate ionic liquids and of 1-hexyl-3-methylimidazolium ionic liquids with different anions were determined in the temperature range between 123 and 393 K on the basis of dielectric measurements in the frequency range from 1 to 10(7) Hz. Most of the ionic liquids form a glass and the conductivity values obey the Vogel-Fulcher-Tammann equation. The glass transition temperatures are increasing with increasing length of the alkyl chain. The fragility is weakly dependent on the alkyl chain length but is highly sensitive to the structure of the anion. (c) 2008 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Special issue on Sensor Systems for Structural Health Monitoring Abstract—This study addresses the direct calibration of optical fiber strain sensors used for structural monitoring and is carried out in situ. The behavior of fiber-Bragg-grating-based sensor systems when attached to metal bars, in a manner representative of their use as reinforcement bars in structures, was examined and their response calibrated. To ensure the validity of the measurements,this was done using an extensometer with a further calibrationagainst the response of electrical resistance strain gauges, often conventionally used, for comparison. The results show a repeatable calibration generating a suitable geometric factor of extension to strain for these sensors, to enable accurate strain data to be obtained when the fiber-optic sensor system is in use in structural monitoring applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability of carbon nanotubes (CNTs) to reinforce and enhance the electrical conductivity of polymer matrices is a function of both the aspect ratio and surface chemistry of the CNTs. Hitherto, due to the variability in MWCNT synthesis methods it has not been possible to study the effect of MWCNT aspect ratio and functionality on polymer composite properties. This paper was the first to report the correlation between MWCNT aspect ratio and functionality on the formation of electrical and rheological percolated networks. Furthermore, the fundamental ballistic conductance of MWCNTs made using arc discharge and chemical vapour deposition techniques was reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a growing interest in the use of geophysical methods to aid investigation and monitoring of complex biogeochemical environments, for example delineation of contaminants and microbial activity related to land contamination. We combined geophysical monitoring with chemical and microbiological analysis to create a conceptual biogeochemical model of processes around a contaminant plume within a manufactured gas plant site. Self-potential, induced polarization and electrical resistivity techniques were used to monitor the plume. We propose that an exceptionally strong (>800 mV peak to peak) dipolar SP anomaly represents a microbial fuel cell operating in the subsurface. The electromagnetic and electrical geophysical data delineated a shallow aerobic perched water body containing conductive gasworks waste which acts as the abiotic cathode of microbial fuel cell. This is separated from the plume below by a thin clay layer across the site. Microbiological evidence suggests that degradation of organic contaminants in the plume is dominated by the presence of ammonium and its subsequent degradation. We propose that the degradation of contaminants by microbial communities at the edge of the plume provides a source of electrons and acts as the anode of the fuel cell. We hypothesize that ions and electrons are transferred through the clay layer that was punctured during the trial pitting phase of the investigation. This is inferred to act as an electronic conductor connecting the biologically mediated anode to the abiotic cathode. Integrated electrical geophysical techniques appear well suited to act as rapid, low cost sustainable tools to monitor biodegradation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An extension of the pole-zero matching method proposed by Stefano Maci et al. for the analysis of electromagnetic bandgap (EBG) structures composed by lossless dipole-based frequency selective surfaces (FSS) printed on stratified dielectric media, is presented in this paper. With this novel expansion, the dipoles length appears as a variable in the analytical dispersion equation. Thus, modal dispersion curves as a function of the dipoles length can be easily obtained with the only restriction of single Floquet mode propagation. These geometry-dispersion curves are essential for the efficient analysis and design of practical EBG structures, such as waveguides loaded with artificial magnetic conductors (AMC) for miniaturization, or leaky-wave antennas (LWA) using partially reflective surfaces (PRS). These two practical examples are examined in this paper. Results are compared with full-wave 2D and 3D simulations showing excellent agreement, thus validating the proposed technique and illustrating its utility for practical designs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the performance characteristics of rapeseed methyl ester, EN 14214 biodiesel, when used for electrical generation in compression ignition engines. The work was inspired by the need to replace fossil diesel fuel with a sustainable low carbon alternative while maintaining generator performance, power quality, and compliance with ISO 8528-5. A 50-kVA Perkins diesel engine generator was used to assess the impact of biodiesel with particular regard to gen-set fuel consumption, load acceptance, and associated standards. Tests were performed on the diesel gen-set for islanded and grid-connected modes of operation, hence both steady-state and transient performance were fully explored. Performance comparisons were made with conventional fossil diesel fuel, revealing minimal technical barriers for electrical generation from this sustainable, carbon benign fuel. Recommendations for improved transient performance are proposed and validated through tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: W/Wv and wild-type murine bladders were studied to determine whether the W/Wv phenotype, which causes a reduction in, but not abolition of, tyrosine kinase activity, is a useful tool to study the function of bladder interstitial cells of Cajal (ICC).

Experimental approach: Immunohistochemistry, tension recordings and microelectrode recordings of membrane potential were performed on wild-type and mutant bladders.

Key results: Wild-type and W/Wv detrusors contained c-Kit- and vimentin-immunopositive cells in comparable quantities, distribution and morphology. Electrical field stimulation evoked tetrodotoxin-sensitive contractions in wild-type and W/Wv detrusor strips. Atropine reduced wild-type responses by 50% whereas a 25% reduction occurred in W/Wv strips. The atropine-insensitive component was blocked by pyridoxal-5-phosphate-6-azophenyl-2',4'-disulphonic acid in both tissue types. Wild-type and W/Wv detrusors had similar resting membrane potentials of -48 mV. Spontaneous electrical activity in both tissue types comprised action potentials and unitary potentials. Action potentials were nifedipine-sensitive whereas unitary potentials were not. Excitatory junction potentials were evoked by single pulses in both tissues. These were reduced by atropine in wild-type tissues but not in W/Wv preparations. The atropine-insensitive component was abolished by pyridoxal-5-phosphate-6-azophenyl-2',4'-disulphonic acid in both preparations.

Conclusions and implications: Bladders from W/Wv mice contain c-Kit- and vimentin-immunopositive ICC. There are similarities in the electrical and contractile properties of W/Wv and wild-type detrusors. However, significant differences were found in the pharmacology of the responses to neurogenic stimulation with an apparent up-regulation of the purinergic component. These findings indicate that the W/Wv strain may not be the best model to study ICC function in the bladder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiresonant high impedance surfaces (HIS) without grounding vias that perform as artificial magnetic conductors (AMC) in multiple frequency bands and furthermore exhibit electromagnetic band gaps (EBG) in the same bands are presented. This is achieved by introducing perturbed frequency selective surface (FSS) arrays printed on grounded dielectric substrates. Arrays of linear dipoles are employed as an example. Perturbations are introduced by means of reducing the length of every other array element. Starting from the characteristics of a perturbed free-standing FSS, the authors present the effect of the perturbation on the excited currents and on the reflection properties of a corresponding AMC. Conclusions about the performance limitations are derived. Subsequently, a parametric study on practical HIS is presented and an optimised design with dual-band AMC and EBG response is demonstrated. Method of moments-based software has been developed and utilised for the fast and accurate analysis of such arrays. Experimental results validate the performance of the optimised structure.