66 resultados para Concrete beams.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gabions are stone-filled wire containers which are frequently used as retaining walls. However, due to their high mass, relatively low cost and visual appeal, a row of single gabion blocks, joined at the ends, has the potential to be used as a roadside impact absorption device where traditional steel or concrete devices may not be suitable. To evaluate such application, the shear and bending deformation of gabions under vehicle impact need to be investigated. In this paper, the shear response of a single gabion block is analytically modelled and a gabion beam multibody model is developed using a discretisation method to capture the deformability of the gabion structure. The material properties of the gabion beam are adopted from experimental values available in the literature and the modelling is statically validated over a three-point bending test and a distributed loading test. The results show that the discretised multibody modelling can be effectively used to describe the static deformation behaviour of gabion blocks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As an alternative to externally bonded FRP reinforcement, near-surface mounted (NSM) FRP reinforcement can be used to effectively improve the flexural performance of RC beams. In such FRP strengthened RC beams, end cover separation failure is one of the common failure modes. This failuremode involves the detachment of the NSM FRP reinforcement together with the concrete cover along the level of the tension steel reinforcement. This paper presents a new strength model for end cover separation failure in RC beams strengthened in flexure with NSM FRP strips (i.e. rectangular FRP bars with asectional height-to-thickness ratio not less than 5), which was formulated on the basis of extensive numerical results from a parametric study undertaken using an efficient finite element approach. The proposed strength model consists of an approximate equation for the debonding strain of the FRP reinforcement at the critical cracked section and a conventional section analysis to relate this debondingstrain to the moment acting on the same section (i.e. the debonding strain). Once the debonding strain is known, the load level at end cover separation of an FRP-strengthened RC beam can be easily determined for a given load distribution. Predictions from the proposed strength model are compared with those of two existing strength models of the same type and available test results, which shows that the proposed strength model is in close agreement with test results and is far more accurate than the existing strength models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A significant increase in strength and performance of reinforced concrete, timber and metal beams may be achieved by adhesively bonding a fibre reinforced polymer composite, or metallic such as steel plate to the tension face of a beam. One of the major failure modes in these plated beams is the debonding of the plate from the original beam in a brittle manner. This is commonly attributed to the interfacial stresses between the adherends whose quantification has led to the development of many analytical solutions over the last two decades. The adherends are subjected to axial, bending and shear deformations. However, most analytical solutions have neglected the effect of shear deformation in adherends. Few solutions consider this effect approximately but are limited to one or two specific loading conditions. This paper presents a more rigorous solution for interfacial stresses in plated beams under an arbitrary loading with the shear deformation of the adherends duly considered in closed form using Timoshenko’s beam theory. The solution is general to linear elastic analysis of prismatic beams of arbitrary cross section under arbitrary loading with a plate of any thickness bonded either symmetrically or asymmetrically with respect to the span of the beam.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The flexural performance of RC beams can be improved using the near-surface mounted (NSM) FRP strengthening technique. A likely failure mode of such FRP-strengthened RC beams is bar-end cover separation which involves the detachment of the NSM FRP reinforcement together with the concrete cover along the level of the steel tension reinforcement. This paper presents a new analytical strength model for this failure mode. The proposed strength model and two existing strength models for this failure mode are compared with test results to demonstrate the superior performance of the new analytical model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RC beams shear-strengthened with externally-bonded FRP side strips or U-strips usually fail by debonding. As such debonding occurs in a brittle manner at relatively small shear crack widths, some of the internal steel stirrups may not have reached yielding at beam shear failure. Consequently, the internal steel stirrups cannot be fully utilized. This adverse shear interaction between internal steel stirrups and external FRP strips may significantly reduce the benefit of shear-strengthening FRP but has not been considered by any of the existing FRP strengthening design guidelines. In this paper, an improved shear strength model capable of accounting for the effect of the above shear interaction is first presented, in which the unfavorable effect of shear interaction is reflected through a reduction factor (i.e. shear interaction factor). Using a large test database established in the present study, the performance of the proposed model as well as that of three other shear strength models is then assessed. This assessment shows that the proposed shear strength model performs better than the three existing models. The assessment also shows that the inclusion of the proposed shear interaction factor in the existing models can significantly improve their performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of short and long term service load tests were undertaken on the sixth floor of the full-scale, seven storey, reinforced concrete building at the Large Building Test Facility of the Building Research Establishment at Cardington. By using internally strain gauged reinforcing bars cast into an internal and external floor bay during the construction process it was possible to gain a detailed record of slab strains resulting from the application of several arrangements of test loads. Short term tests were conducted in December 1998 and long term monitoring then ensued until April 2001. This paper describes the test programmes and presents results to indicate slab behaviour for the various loading regimes.