48 resultados para Brick masonry
Resumo:
Weathering of stone is one of the major reasons for the damage of stone masonry structures and it takes place due to interlinked chemical, physical and biological processes in stones. The key parameters involved in the deterioration processes are temperature, moisture and salt. It is now known that the sudden variations in temperature and moisture greatly accelerate the weathering process of the building stone fabric. Therefore, in order to monitor these sudden variations an effective and continuous monitoring system is needed. Furthermore, it must consist of robust sensors which are accurate and can survive in the harsh environments experienced in and around masonry structures. Although salt penetration is important for the rate of deterioration of stone masonry structures, the processes involved are much slower than the damage associated with temperature and moisture variations. Therefore, in this paper a novel fibre optic temperature cum relative humidity sensor is described and its applicability in monitoring building stones demonstrated. The performance of the sensor is assessed in an experiment comprising wetting and drying of limestone blocks. The results indicate that the novel fibre optic relative humidity sensor which is tailor made for applications in masonry structures performed well in wetting and drying tests, whilst commercial capacitance based sensors failed to recover during the drying regime for a long period after a wetting regime. That is, the fibre optic sensor has the capability to measure both sorption and de-sorption characteristics of stone blocks. This sensor is used in a test wall in Oxford and the data thus obtained strengthened the laboratory observations.
Resumo:
A vibrant inner city parish needed space for meetings, language classes, children’s play and other support accommodation as well as a clearer link between the interior of the listed church and the space outside.
The project builds itself about the entrance to the church. The form is manipulated such that the intervention recedes from those entering the church, drawing them into the plan before becoming readable as an addition. The resultant poché between this entrance sequence and the fabric of the church is hollowed out to provide the required accommodation. These rooms are insulated and lined in cork to allow for their use separate to the main body of the church. With budget at a premium the construction methodology was developed from an analysis of traditional Irish boat building techniques, which allowed the use of the solid timber to act as the primary structure with no additional material support.
Constructed in solid walnut the intervention reads with the existing brick interior and yet is clearly identifiable as a contemporary addition.
Aims / Objectives Questions
1 To accommodate new space inside an existing protected structure.
2 To form a new threshold between interior and exterior.
3 To develop an affordable means of construction that would be durable and rapid to erect.
4 To make a contemporary addition in sympathy with the qualities of the existing protect structure, in line with best conservation practice and research.
5 Traditional forms of construction as a model for contemporary technologies.
Principal Investigator: Clancy Moore Architects –Colm Moore
Co-investigator(s): Andrew Clancy, Mathew O’Malley
Funding partner/ Client: Select Vestry of St George and St Thomas
Finance. €35’000
Date (start – finished) Start June 2008 – Completed December 2008
Resumo:
In spite of the fact that the laterite masonry was often used for building, during the colonial period, the laterite rock is rarely studied. To resolve the economic and environmental problems, concerning the concrete or cinder block construction in Africa, this material can be again a local resource. The objective is to determine the hydro-thermo-mechanical properties of laterite rocks linking with the local geological conditions, to investigate the possibilities to be used in construction housing, sufficiently able to resist to limited loads and to give thermal comfort inside. Some preliminary results are presented here.
Resumo:
This paper presents the preliminary results of geological and geomechanical studies on the laterite stone exploited at Dano quarry in Burkina Faso. The field work described the geological structure of quarry sites and their environment to determine the rocks alteration and the links between the bedrock and lateritic material. Physic-mechanical properties have been studied for assessing the potentiality of this material for lightweight housing, to be completed with thermal and environmental considerations. Some social and economic evaluations are in progress in order to foster its utilization under local conditions.
Hygrothermal Features of Laterite Dimension Stones for Sub-Saharan Residential Building Construction
Resumo:
The building sector is widely recognized as having a major impact on sustainable development. Both in developed and developing countries, sustainability in buildings approaches are growing. Laterite dimension stone (LDS) is a building material that was traditionally used in sub-Saharan Africa, but its technical features still need to be assessed. This article presents some results of a study focused on the characterization of LDS exploited in Burkina Faso for building purposes. The measured average thermal conductivity is 0.51 W/mK, which increases with water content and evolves with the specific gravity and with porosity. Rock mineral phases (quartz, goethite, hematite, magnetite) are cemented by kaolinite. The porosity of the material is high (30%), with macropores visible on the surface and found in the rock inner structure as well. Results from the hygrothermal monitoring of a pilot building are also presented.
Resumo:
The burial of objects (human remains, explosives, weapons) below or behind concrete, brick, plaster or tiling may be associated with serious crime and are difficult locations to search. These are quite common forensic search scenarios but little has been published on them to-date. Most documented discoveries are accidental or from suspect/witness testimony. The problem in locating such hidden objects means a random or chance-based approach is not advisable. A preliminary strategy is presented here, based on previous studies, augmented by primary research where new technology or applications are required. This blend allows a rudimentary search workflow, from remote desktop study, to non-destructive investigation through to recommendations as to how the above may inform excavation, demonstrated here with a case study from a homicide investigation. Published case studies on the search for human remains demonstrate the problems encountered when trying to find and recover sealed-in and sealed over locations. Established methods include desktop study, photography, geophysics and search dogs:these are integrated with new technology (LiDAR and laser scanning; photographic rectification; close quarter aerial imagery; ground-penetrating radar on walls and gamma-ray/neutron activation radiography) to propose this possible search strategy.
Resumo:
This study describes an innovative monolith structure designed for applications in automotive catalysis using an advanced manufacturing approach developed at Imperial College London. The production process combines extrusion with phase inversion of a ceramic-polymer-solvent mixture in order to design highly ordered substrate micro-structures that offer improvements in performance, including reduced PGM loading, reduced catalyst ageing and reduced backpressure.
This study compares the performance of the novel substrate for CO oxidation against commercially available 400 cpsi and 900 cpsi catalysts using gas concentrations and a flow rate equivalent to those experienced by a full catalyst brick when attached to a vehicle. Due to the novel micro-structure, no washcoat was required for the initial testing and 13 g/ft3 of Pd was deposited directly throughout the substrate structure in the absence of a washcoat.
Initial results for CO oxidation indicate that the advanced micro-structure leads to enhanced conversion efficiency. Despite an 79% reduction in metal loading and the absence of a washcoat, the novel substrate sample performs well, with a light-off temperature (LOT) only 15 °C higher than the commercial 400 cpsi sample.
To test the effects of catalyst ageing on light-off temperature, each sample was aged statically at a temperature of 1000 °C, based on the Bench Ageing Time (BAT) equation. The novel substrate performed impressively when compared to the commercial samples, with a variation in light-off temperature of only 3% after 80 equivalent hours of ageing, compared to 12% and 25% for the 400 cpsi and 900 cpsi monoliths, respectively.
Resumo:
Abstract. The possibility of using pumice aggregates for concrete in structural applications is discussed. In particular, the mix design of lightweight concrete for the manufacturing masonry units having proper strength, is discussed. Moreover, the design of the unit shape according to the technical code requirements and making it possible to arrange reinforcing steel bars is described. Reinforced bearing masonry walls, made with the concrete units in question, were manufactured and tests on the panels and on the designed units were carried out. For comparison, tests on concrete units and structural elements were carried out after the substitution of pumice aggregates with ordinary lightweight aggregates, proving that pumice can be considered an alternative to them. Sommario. L’uso della pomice come inerte per il confezionamento di calcestruzzo è poco diffuso sebbene essa sia stata usata già in antiche costruzioni come il Pantheon in Roma. In questo studio si affronta la possibilità di realizzare blocchi in calcestruzzo alleggerito con granuli di pomice. I blocchi, progettati e realizzati secondo le indicazioni normative correnti, sono stati usati per realizzare pannelli murari armati da sottoporre a carichi ciclici orizzontali. I risultati ottenuti, messi a confronto con quelli di pannelli realizzati con blocchi in cls alleggerito con argilla espansa, hanno mostrato la possibilità di utilizzare la pomice come validissima alternativa all’argilla espansa.
Resumo:
As a consequence of climate change there is now a more frequent occurrence of extreme rainfall events where, with higher rates of urbanisation, the built environment has become increasingly affected by flooding.. This is of particular importance in relation to the stability of bridge structures that span rivers and canals etc. In November 2009, the UK and Ireland were subjected to extraordinarily severe weather conditions for several days. The rainfall was logged as the highest level of rainfall ever recorded within the UK, and as a direct consequence, unprecedented flooding occurred in Cumbria. This flooding led to the collapse of three road bridges which were generally 19th century masonry arch bridges, with relatively shallow foundations. In the UK, knowledge of the combined effect of bridge scouring and inundation has been not been particularly widely studied. Research carried out by Hamill et al [1] considered the hydraulic analysis of single arch bridges under flood conditions, but no consideration was given towards the likely damage to these structures due to scouring. Prior to this, Bierry and Delleur [2] produced a classic paper in predicting the discharge downstream of an inundated arch, focussing on predicting afflux as opposed to bridge scour. Further work on backwater effects was carried out by Martin-Vide & Prio [3] in semi-circular arch bridges. Both pressurized and free-surface flows at the bridge were investigated. Flows on a mobile bed in clear-water conditions were compared to those with a rigid bed, but no predictive equation for scour under pressurised conditions was considered. This paper will present initial findings from an experimental investigation into the effects of surcharged flow and subsequent scour within the vicinity of single span arch bridges. Velocities profiles will be shown within the vicinity of the arch, in addition to the depth of clear water scour, for a series of flows and model spans. The data will be presented, where results will be correlated to the most recent predictive equations that are proposed.
Resumo:
The influence of masonry infills on the in-plane behaviour of RC framed structures is a central topic in the seismic evaluation and retrofitting of existing buildings. Many models in the literature use an equivalent strut member in order to represent the infill but, among the parameters influencing the equivalent strut behaviour, the effect of vertical loads acting on the frames is recognized but not quantified. Nevertheless a vertical load causes a non-negligible variation in the in-plane behaviour of infilled frames by influencing the effective volume of the infill. This results in a change in the stiffness and strength of the system. This paper presents an equivalent diagonal pin-jointed strut model taking into account the stiffening effect of vertical loads on the infill in the initial state. The in-plane stiffness of a range of infilled frames was evaluated using a finite element model of the frame-infill system and the cross-section of the strut equivalent to the infill was obtained for different levels of vertical loading by imposing the equivalence between the frame containing the infill and the frame containing the diagonal strut. In this way a law for identifying the equivalent strut width depending on the geometrical and mechanical characteristics of the infilled frame was generalized to consider the influence of vertical loads for use in the practical applications. The strategy presented, limited to the initial stiffness of infilled frames, is preparatory to the definition of complete non-linear cyclic laws for the equivalent strut.
Resumo:
As a consequence of increased levels of flooding, largely attributable to urbanization of watersheds (and perhaps climate change, more frequent extreme rainfall events are occurring and threatening existing critical infrastructure. Many of which are short-span bridges over relatively small waterways (e.g., small rivers, streams and canals). Whilst these short-span bridges were designed, often many years ago, to pass relatively minor the then standard return-period floods, in recenttimes the failure incidence of such short-span bridges has been noticeably increasing. This is suggestive of insufficient hydraulic capacity or alternative failure mechanism not envisaged at the time of design e.g. foundation scour or undermining. This paper presen ts, and draws lessons, from bridge failures in Ireland and the USA. For example, in November 2009, the UK and Ireland were subjected to extraordinarily severe weather conditions for several days. The resulting flooding led to the collapse of three UK bridges that were generally 19th century masonry arch bridges, withrelatively shallow foundations. Parallel failure events have been observed in the USA. To date, knowledge of the combined effect of waterway erosion, bridge submergence, and geotechnical collapse has not been adequately studied. Recent research carried out considered the hydraulic analysis of short span bridges under flood conditions, but no consideration was given towards the likely damage to these structures due to erosive coupling of hydraulic and geotechnical factors. Some work has been done to predict the discharge downstream of an inundated arch, focusing onpredicting afflux, as opposed to bridge scour, under both pressurized and free-surface flows, but no ! predictive equation for scour under pressurized conditions was ever considered. The case studies this paper presents will be augmented by the initial findings from the laboratory experiments investigating the effects of surcharged flow and subsequent scour within the vicinity of single span arch bridges. Velocities profiles will be shown within the vicinity of the arch, in addition to the depth of consequent scour, for a series of flows and model spans. The data will be presented and correlated to the most recent predictive equations for submerged contraction and abutment scour. The accuracy of these equations is examined, and the findings used as a basis for developing further studies in relation to short span bridges.
Resumo:
Strengthening reinforced concrete (RC) structures by externally bonded FRP composites has been widely used for static loading and seismic retrofitting since 1990s. More recently many studies on strengthening concrete and masonry structures with externally bonded FRP for improved blast and impact resistance in protective engineering have also been conducted. The bond behaviour between the FRP and concrete plays a critical role in a strengthening system with externally bonded FRP. However, the understanding of how the bond between FRP and concrete performs under high strain rate is severely limited. Due to the dynamic characteristics of blast and impact loading, the bond behaviour between FRP and concrete under such loading is very different from that under static loading. This paper presents a study on the dynamic bond-slip behaviour based on both the numerical analysis and test results. A dynamic bond-slip model is proposed in this paper.
Resumo:
Contemporary architecture has tended to increase envelope insulation levels in an unceasing effort to reduce U-values. Traditional masonry architecture in contrast was devoid of insulation, except for the inherent insulative nature of vernacular materials. Also the consistency of the outer membrane of the building skin diminished any impact due to bridging. In contemporary highly insulated walls bridges are numerous due to the necessity to bind inner and outer structural skins through insulation layers. This paper examines thermal bridging in an example of contemporary façade design and compares it with an example of traditional vernacular architecture currently being researched which is characterized by a lack of bridging elements. Focus is given to heavy weight materials of high thermal mass, which appropriately for passive architecture help moderate fluctuations in internal temperature. In an extensive experimental study samples of highly insulated precast concrete sandwich panels and lime rendered masonry walls are tested in a guarded hot-box. The building construction methods are compared for static and dynamic thermal transmittance, via heat flux and surface temperature differential measurements. Focus is given to the differential heat loss due to the thermal bridging in the sandwich panels and its associated impact on overall heat loss relative to traditional masonry construction.
Resumo:
The potential benefits of combining the elegance of the stress ribbon concept with the robustness and speed of construction of the FlexiArch is discussed. In combination, multi-span pedestrian/cycle bridges which are innovative, highly durable and have optimal full life cycle costs can be produced with lengths of over 100 m. As the stress ribbon system is well known, the main emphasis of this paper will be on the FlexiArch. Since 1900 few arch bridges have been built, but with the development of the innovative FlexiArch this trend can be reversed as they can be installed rapidly, are cost competitive, have all the attributes of masonry arches and are very sustainable. Thus the FlexiArch represents a very attractive alternative to heavily reinforced cast in situ arches currently used in combination with stress ribbon deck systems.