72 resultados para Basophil Degranulation Test -- methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports on the accuracy of new test methods developed to measure the air and water permeability of high-performance concretes (HPCs). Five representative HPC and one normal concrete (NC) mixtures were tested to estimate both repeatability and reliability of the proposed methods. Repeatability acceptance was adjudged using values of signal-noise ratio (SNR) and discrimination ratio (DR), and reliability was investigated by comparing against standard laboratory-based test methods (i.e., the RILEM gas permeability test and BS EN water penetration test). With SNR and DR values satisfying recommended criteria, it was concluded that test repeatability error has no significant influence on results. In addition, the research confirmed strong positive relationships between the proposed test methods and existing standard permeability assessment techniques. Based on these findings, the proposed test methods show strong potential to become recognized as international methods for determining the permeability of HPCs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The integral variability of raw materials, lack of awareness and appreciation of the technologies for achieving quality control and lack of appreciation of the micro and macro environmental conditions that the structures will be subjected, makes modern day concreting a challenge. This also makes Designers and Engineers adhere more closely to prescriptive standards developed for relatively less aggressive environments. The data from exposure sites and real structures prove, categorically, that the prescriptive specifications are inadequate for chloride environments. In light of this shortcoming, a more pragmatic approach would be to adopt performance-based specifications which are familiar to industry in the form of specification for mechanical strength. A recently completed RILEM technical committee made significant advances in making such an approach feasible.
Furthering a performance-based specification requires establishment of reliable laboratory and on-site test methods, as well as easy to perform service-life models. This article highlights both laboratory and on-site test methods for chloride diffusivity/electrical resistivity and the relationship between these tests for a range of concretes. Further, a performance-based approach using an on-site diffusivity test is outlined that can provide an easier to apply/adopt practice for Engineers and asset managers for specifying/testing concrete structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Age related macular degeneration (AMD) is a common cause of severe vision loss. Identification of genes involved in AMD will facilitate early detection and ultimately help to identify pathways for treatment for this disorder. The A16,263G mutation in the HEMICENTIN-1 gene produces a non-conservative substitution of arginine for glutamine at codon 5345 which has been implicated in familial AMD. The aim of this study is to develop a rapid diagnostic assay for the detection of this mutation and to evaluate its frequency in a sample of AMD patients. Methods: A primer probe set was designed from exon 104 of the HEMICENTIN-1 gene to differentiate between mutant and wild type alleles. A region spanning the mutation was amplified by PCR using a LightCycler (Roche Diagnostic). The mutation was then detected by melt curve analysis of the hybrid formed between the PCR product and a specific fluorescent probe. The frequency of the mutation within the Northern Ireland population was evaluated by assaying 508 affected AMD patients, 25 possibly affected and 163 controls. Results: This assay clearly discriminates between the A16,263G mutant and wild type HEMICENTIN-1 alleles. The wild type sequence has a single base mismatch with the probe which decreases the stability of the hybrid, resulting in a lower TM (TM=51.27 °C) than that observed for the perfectly matched mutant allele (TM=59.9 °C). The mutant allele was detected in only one of the 696 subjects, an affected AMD patient. Conclusions: We describe a rapid assay for the genotyping of the Gln5345Arg mutation using real-time fluorescence PCR to facilitate rapid processing of samples through combined amplification and detection steps. These characteristics are suitable for a clinical setting where high throughput diagnostic procedures are required. The frequency of this mutation within the Northern Ireland population has been estimated at 0.2%, concurring with previous findings that this mutation is a rare variant associated with AMD. A rapid diagnostic assay will facilitate a reliable and convenient evaluation of the frequency of the Gln5345Arg mutation and its association with AMD within other populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose The purpose of this study was to investigate if pepsin measured in sputum is a useful marker of pulmonary aspiration secondary to gastroesophageal reflux (GER) in children. It is possible that the induced sputum procedure could cause GER and invalidate the results. The hypothesis stated that healthy children (those without history of respiratory or gastroesophageal symptoms) would not have pepsin detected in induced sputum. Methods Children attending surgical outpatients in the Royal Belfast Hospital for Sick Children (Belfast, Northern Ireland) were recruited. After spirometry, sputum was obtained by induction with hypertonic 3% saline. Spirometry was repeated, and complications were noted. An “in-house” enzyme-linked immunosorbent assay was used to measure pepsin concentration in sputum. The lower limit of detection of pepsin was 1.19 ng/mL. Results Children (n = 21) aged 4 to 16 years were recruited. Twenty children completed the study. No adverse effects were reported. Pepsin was detected in 17 (85%) of 20 sputum samples. Conclusions The act of sputum induction appears to induce physiologic GER in a healthy childhood population. The analysis of pepsin in sputum obtained by sputum induction is therefore not useful in the investigation of reflux-related respiratory disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:


Background


Metachromatic cells obtained from asthmatic subjects demonstrate increased spontaneous and stimulated histamine release in vitro. Their ability to synthesize and store proinflammatory cytokines has focused renewed interest on their role in asthma.


Objective: The late asthmatic response provides a useful model of clinical asthma. The aim of the study was to examine metachromatic cell derived mediators and histamine releasability in vitro after in vivo allergen exposure in atopic subjects with and without asthma and relate them to the type of physiological response observed.

Methods: Bronchoalveolar lavage (BAL) cells were obtained 4 h after challenge from asthmatics exhibiting a single early response (EAR, n = 5), a dual response (LAR, n = 7), unchallenged (basal, n = 5), atopic non-asthmatic (ANA, n = 6) and non-atopic non-asthmatics (normal, n = 5). BAL histamine and tryptase concentrations and in vitro histamine release (HR) after stimulation with anti-IgE, allergen, A23187, conconavalin A and substance P were compared.

Results:Metachromatic cell numbers were lower in normal controls compared with all asthmatic groups and in LAR compared with EAR. Metachromatic cell derived mediators were higher in asthmatic compared with normal subjects. Spontaneous HR in LAR (20.5 ± 5.0%) was lower than EAR (29.5 ± 3.9%) and ANA (30.2 ± 1.4%) (P < 0.05). No differences were seen in stimulated HR between EAR and LAR. HR in ANA stimulated with anti-IgE was greater than LAR (P < 0.05). HR in ANA stimulated with anti-IgE was greater than LAR (P < 0.05). After stimulation with ionophore A23187 (1 μM), release was greater in LAR compared with basal (P < 0.05) and no different at 5 μM. All subject groups responded to substance P (SP) but was significantly more in the asthmatic subjects compared to normal controls (P < 0.05). Allergen challenge did not modify the response of asthmatic subjects to SP.

Conclusion: Functional differences in metachromatic cell reactivity are present in atopic subjects 4 h after in vivo allergen exposure which relate to the physiological response observed after this time and suggest that there is ongoing metachromatic cell degranulation subjects who subsequently develop LAR.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Retinitis pigmentosa (RP) causes hereditary blindness in adults (prevalence, approximately 1 in 4000). Each of the more than 30 causative genes identified to date are responsible for only a small percentage of cases. Genetic diagnosis via traditional methods is problematic, and a single test with a higher probability of detecting the causative mutation would be very beneficial for the clinician. The goal of this study therefore was to develop a high-throughput screen capable of detecting both known mutations and novel mutations within all genes implicated in autosomal recessive or simplex RP. DESIGN: Evaluation of diagnostic technology. PARTICIPANTS AND CONTROLS: Participants were 56 simplex and autosomal recessive RP patients, with 360 population controls unscreened for ophthalmic disease. METHODS: A custom genechip capable of resequencing all exons containing known mutations in 19 disease-associated genes was developed (RP genechip). A second, commercially available arrayed primer extension (APEX) system was used to screen 501 individual previously reported variants. The ability of these high-throughput approaches to identify pathogenic variants was assessed in a cohort of simplex and autosomal recessive RP patients. MAIN OUTCOME MEASURES: Number of mutations and potentially pathogenic variants identified. RESULTS: The RP genechip identified 44 sequence variants: 5 previously reported mutations; 22 known single nucleotide polymorphisms (SNPs); 11 novel, potentially pathogenic variants; and 6 novel SNPs. There was strong concordance with the APEX array, but only the RP genechip detected novel variants. For example, identification of a novel mutation in CRB1 revealed a patient, who also had a single previously known CRB1 mutation, to be a compound heterozygote. In some individuals, potentially pathogenic variants were discovered in more than one gene, consistent with the existence of disease modifier effects resulting from mutations at a second locus. CONCLUSIONS: The RP genechip provides the significant advantage of detecting novel variants and could be expected to detect at least one pathogenic variant in more than 50% of patients. The APEX array provides a reliable method to detect known pathogenic variants in autosomal recessive RP and simplex RP patients and is commercially available. High-throughput genotyping for RP is evolving into a clinically useful genetic diagnostic tool.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Postal and electronic questionnaires are widely used for data collection in epidemiological studies but non-response reduces the effective sample size and can introduce bias. Finding ways to increase response to postal and electronic questionnaires would improve the quality of health research. Objectives: To identify effective strategies to increase response to postal and electronic questionnaires. Search strategy: We searched 14 electronic databases to February 2008 and manually searched the reference lists of relevant trials and reviews, and all issues of two journals. We contacted the authors of all trials or reviews to ask about unpublished trials. Where necessary, we also contacted authors to confirm methods of allocation used and to clarify results presented. We assessed the eligibility of each trial using pre-defined criteria. Selection criteria: Randomised controlled trials of methods to increase response to postal or electronic questionnaires. Data collection and analysis: We extracted data on the trial participants, the intervention, the number randomised to intervention and comparison groups and allocation concealment. For each strategy, we estimated pooled odds ratios (OR) and 95% confidence intervals (CI) in a random-effects model. We assessed evidence for selection bias using Egger's weighted regression method and Begg's rank correlation test and funnel plot. We assessed heterogeneity among trial odds ratios using a Chi 2 test and the degree of inconsistency between trial results was quantified using the I 2 statistic. Main results: Postal We found 481 eligible trials.The trials evaluated 110 different ways of increasing response to postal questionnaires.We found substantial heterogeneity among trial results in half of the strategies. The odds of response were at least doubled using monetary incentives (odds ratio 1.87; 95% CI 1.73 to 2.04; heterogeneity P < 0.00001, I 2 = 84%), recorded delivery (1.76; 95% CI 1.43 to 2.18; P = 0.0001, I 2 = 71%), a teaser on the envelope - e.g. a comment suggesting to participants that they may benefit if they open it (3.08; 95% CI 1.27 to 7.44) and a more interesting questionnaire topic (2.00; 95% CI 1.32 to 3.04; P = 0.06, I 2 = 80%). The odds of response were substantially higher with pre-notification (1.45; 95% CI 1.29 to 1.63; P < 0.00001, I 2 = 89%), follow-up contact (1.35; 95% CI 1.18 to 1.55; P < 0.00001, I 2 = 76%), unconditional incentives (1.61; 1.36 to 1.89; P < 0.00001, I 2 = 88%), shorter questionnaires (1.64; 95%CI 1.43 to 1.87; P < 0.00001, I 2 = 91%), providing a second copy of the questionnaire at follow up (1.46; 95% CI 1.13 to 1.90; P < 0.00001, I 2 = 82%), mentioning an obligation to respond (1.61; 95% CI 1.16 to 2.22; P = 0.98, I 2 = 0%) and university sponsorship (1.32; 95% CI 1.13 to 1.54; P < 0.00001, I 2 = 83%). The odds of response were also increased with non-monetary incentives (1.15; 95% CI 1.08 to 1.22; P < 0.00001, I 2 = 79%), personalised questionnaires (1.14; 95% CI 1.07 to 1.22; P < 0.00001, I 2 = 63%), use of hand-written addresses (1.25; 95% CI 1.08 to 1.45; P = 0.32, I 2 = 14%), use of stamped return envelopes as opposed to franked return envelopes (1.24; 95% CI 1.14 to 1.35; P < 0.00001, I 2 = 69%), an assurance of confidentiality (1.33; 95% CI 1.24 to 1.42) and first class outward mailing (1.11; 95% CI 1.02 to 1.21; P = 0.78, I 2 = 0%). The odds of response were reduced when the questionnaire included questions of a sensitive nature (0.94; 95% CI 0.88 to 1.00; P = 0.51, I 2 = 0%). Electronic: We found 32 eligible trials. The trials evaluated 27 different ways of increasing response to electronic questionnaires. We found substantial heterogeneity among trial results in half of the strategies. The odds of response were increased by more than a half using non-monetary incentives (1.72; 95% CI 1.09 to 2.72; heterogeneity P < 0.00001, I 2 = 95%), shorter e-questionnaires (1.73; 1.40 to 2.13; P = 0.08, I 2 = 68%), including a statement that others had responded (1.52; 95% CI 1.36 to 1.70), and a more interesting topic (1.85; 95% CI 1.52 to 2.26). The odds of response increased by a third using a lottery with immediate notification of results (1.37; 95% CI 1.13 to 1.65), an offer of survey results (1.36; 95% CI 1.15 to 1.61), and using a white background (1.31; 95% CI 1.10 to 1.56). The odds of response were also increased with personalised e-questionnaires (1.24; 95% CI 1.17 to 1.32; P = 0.07, I 2 = 41%), using a simple header (1.23; 95% CI 1.03 to 1.48), using textual representation of response categories (1.19; 95% CI 1.05 to 1.36), and giving a deadline (1.18; 95% CI 1.03 to 1.34). The odds of response tripled when a picture was included in an e-mail (3.05; 95% CI 1.84 to 5.06; P = 0.27, I 2 = 19%). The odds of response were reduced when "Survey" was mentioned in the e-mail subject line (0.81; 95% CI 0.67 to 0.97; P = 0.33, I 2 = 0%), and when the e-mail included a male signature (0.55; 95% CI 0.38 to 0.80; P = 0.96, I 2 = 0%). Authors' conclusions: Health researchers using postal and electronic questionnaires can increase response using the strategies shown to be effective in this systematic review. Copyright © 2009 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.


--------------------------------------------------------------------------------

Reaxys Database Information|

--------------------------------------------------------------------------------

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose
This study was designed to investigate methods to help patients suffering from unilateral tinnitus synthesizing an auditory replica of their tinnitus.

Materials and methods
Two semi-automatic methods (A and B) derived from the auditory threshold of the patient and a method (C) combining a pure tone and a narrow band-pass noise centred on an adjustable frequency were devised and rated on their likeness over two test sessions. A third test evaluated the stability over time of the synthesized tinnitus replica built with method C, and its proneness to merge with the patient's tinnitus. Patients were then asked to try and control the lateralisation of this single percept through the adjustment of the tinnitus replica level.

Results
The first two tests showed that seven out of ten patients chose the tinnitus replica built with method C as their preferred one. The third test, performed on twelve patients, revealed pitch tuning was rather stable over a week interval. It showed that eight patients were able to consistently match the central frequency of the synthesized tinnitus (presented to the contralateral ear) to their own tinnitus, which leaded to a unique tinnitus percept. The lateralisation displacement was consistent across patients and revealed an average range of 29dB to obtain a full lateral shift from the ipsilateral to the contralateral side.

Conclusions
Although spectrally simpler than the semi-automatic methods, method C could replicate patients' tinnitus, to some extent. When a unique percept between synthesized tinnitus and patients' tinnitus arose, lateralisation of this percept was achieved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The continuing interest in semiconductor photochemistry, SPC, and the emergence of commercial products that utilise films of photocatalyst materials, has created an urgent need to agree a set of methods for assessing photocatalytic activity and international committees are now meeting to address this issue. This article provides a brief overview of two of the most popular current methods employed by researchers for assessing SPC activity. and one which has been published just recently and might gain popularity in the future, given its ease of use. These tests are: the stearic acid (SA) test, the methylene blue (MB) test and the resazurin (Rz) ink test, respectively. The basic photochemical and chemical processes that underpin each of these tests are described, along with typical results for laboratory made sol-gel titania films and a commercial form of self-cleaning glass, Activ (TM). The pros and cons of their future use as possible standard assessment techniques are considered. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whilst there are a number of methods available to characterise the cell surface hydrophobicity (CSH) and cell surface charge (CSC) of microorganisms, there is still debate concerning the correlation of results between individual methods. In this study, the techniques of bacterial adherence to hydrocarbons (BATH) and hydrophobic interaction chromatography (HTC) were used to measure CSH. Electrostatic interaction chromatography (ESIC) and zeta potential (ZP) measurements were used to determine CSC. To allow meaningful comparisons between the BATH and HIC tests, between ESIC and ZP and also between CSH and CSC, the buffer systems employed in each test were standardised (phosphate buffered saline, pH 7.3, 0.01 mM). Isolates of Staphylococcus epidermidis derived from microbial biofilm were used as the test organism in this study. The isolates examined exhibited primarily medium to high CSH and a highly negative CSC. Good correlation of CSH measurement was observed between the BATH and HIC tests (r = 0.89). Good correlation was observed between ESIC (anionic exchange column) and ZP measurements. No correlations were observed between isolate CSC and either increased or decreased CSH. It is recommended that whenever comparisons of various methods to determine either CSC or CSH (by partitioning methods), the buffer systems should remain constant throughout to achieve consistency of results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of three non-antibiotic, antimicrobial agents (taurolidine, chlorhexidine acetate and providone-iodine) on the surface hydrophobicity of the clinical strains Escherichia coli, Staphylococcus saprophyticus, Staphylococcus epidermidis and Candida albicans were examined. Three recognized techniques for hydrophobicity measurements, Bacterial Adherence to Hydrocarbons (BATH), the Salt Aggregation Test (SAT) and Hydrophobic Interaction Chromatography (HIC) were compared. At concentrations reported to interfere with microbial-epithelial cell adherence, all three agents altered the cell surface hydrophobicity. However, these effects failed to exhibit a uniform relationship. Generally, taurolidine and povidone-iodine treatments decreased the hydrophobicity of the strains examined whereas chlorhexidine acetate effects depended upon the micro-organism treated. Subsequently, the exact contribution of altered cell surface hydrophobicity to the reported microbial anti-adherence effects is unclear. Comparison of the three techniques revealed a better correlation between the results obtained with the BATH test and HIC than the results obtained with the BATH and SAT or SAT and HIC. However, these differences may be due to the inaccuracy associated with the visual assessment of results employed by the SAT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper examines the activation and inhibition of activation of human basophils. After a brief description of human basophils, different methods to determine basophil activation are discussed with a special emphasis on the use of flow cytometric methods, as these circumvent the potential problems of assays based on the loss of colour by activated basophils. The activation of human basophils by ultra-high dilutions of anti-IgE is discussed. The majority of the paper describes the inhibition of basophil activation by ultra-high dilutions of histamine. The results from published papers are described and discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Numerous methods are available to measure the permeation properties of concrete, which can be classified in terms of the diffusion, absorption and permeability properties. The results from these tests are generally used to infer 'quality' or relative durability. Some of these tests involve the laboratory assessment of a sample of concrete extracted from the structure. However, this Technical Note concentrates on the alternative methods appropriate for use on site. Guidance is given on the choice of an appropriate test method, which in most practical situations depends on the predominant mechanism acting on the concrete under consideration.