227 resultados para Alpha-Si3N4


Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-cadence Halpha blue wing observations of a C9.6 solar flare obtained at Big Bear Solar Observatory using the Rapid Dual Imager are presented. Wavelet and time-distance methods were used to study oscillatory power along the ribbon, finding periods of 40 - 80 s during the impulsive phase of the flare. A parametric study found statistically significant intensity oscillations with amplitudes of 3% of the peak flare amplitude, periods of 69 s (14.5 mHz) and oscillation decay times of 500 s. These measured properties are consistent with the existence of flare-induced acoustic waves within the overlying loops.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied the emission of Kalpha radiation from Ti foils irradiated with ultrashort (45 fs) laser pulses. We utilized the fundamental (800 nm) light from a Ti:sapphire laser on bare foils and foils coated with a thin layer of parylene E (CH). The focusing was varied widely to give a range of intensities from approximately 10(15)-10(19) W cm(-2). Our results show a conversion efficiency of laser to Kalpha energy of similar to 10(-4) at tight focus for both types of targets. In addition, the coated targets exhibited strong secondary peaks of conversion at large defocus, which we believe are due to modification of the extent of preformed plasma due to the dielectric nature of the plastic layer. This in turn affects the level of resonance absorption. A simple model of Kalpha production predicts a much higher conversion than seen experimentally and possible reasons for this are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study of the K-alpha radiation emitted from Ti foils irradiated with intense, similar to0.2 J, 67 fs, 800 nm laser pulses, scanning a range of intensities (similar to10(15)-10(18) W cm(-2)), is reported. The brightness of single-shot K-alpha line emission from the front of the targets is recorded. The yield from bare titanium (Ti) is compared to that from plastic (parylene-E) coated Ti. It is demonstrated that, for a defocused beam, a thin layer of plastic increases the yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The venoms of buthid scorpions are known to contain basic, single-chain protein toxins (alpha toxins) consisting of 60–70 amino acid residues that are tightly folded by four disulfide bridges. Here we describe isolation and sequencing of three novel putative alpha toxins (AamH1-3) from the venom of the North African scorpion, Androctonus amoreuxi, and subsequent cloning of their precursor cDNAs from the same sample of venom. This experimental approach can expedite functional genomic analyses of the protein toxins from this group of venomous animals and does not require specimen sacrifice for cloning of protein toxin precursor cDNAs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neutrophil elastase (NE) is thought to be the most important protease which damages the cystic fibrosis (CF) lung. Attempts have been made to suppress this activity using the plasma-derived inhibitor, alpha1-antitrypsin (AAT). In this pilot study, the safety and efficacy of inhaled recombinant human AAT (rAAT) as a treatment for CF were investigated. Thirty-nine patients participated in a prospective, double-blinded, randomized, placebo-controlled phase II trial to examine the effect of rAAT (500, 250, and 125 mg) on sputum NE activity. Sputum myeloperoxidase (MPO), interleukin-8, tumor necrosis factor receptors, sputum and plasma NE/AAT complexes, and safety parameters were also measured. Subjects were randomized to receive nebulized treatment once a day for 4 weeks, followed by 2–4 weeks with no study treatment, and then a 2-week rechallenge phase. Trends toward a reduction in NE activity were observed in patients treated with 500 mg and 250 mg of rAAT compared to placebo. Sputum NE/AAT complex and MPO levels were lower on rAAT compared to placebo. No major adverse events and, in particular, no allergic reactions to rAAT were observed. Although significant differences between rAAT and placebo for sputum NE activity were not observed, some improvements were found for secondary efficacy variables. This study demonstrated that nebulized rAAT is safe and well-tolerated, but has a limited effect on NE activity and other markers of inflammation. Pediatr Pulmonol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a study comparing absolute K-alpha yield from Ti foils measured with a calibrated system of an X-ray CCD coupled to a curved LiF Von-Hamos crystal spectrometer to the difference in the signals measured simultaneously with two similar photodiodes fitted with two different filters. Our data indicate that a combination of photodiodes with different filters could be developed into an alternative and inexpensive diagnostic for monitoring single shot pulsed emission in a narrow band of X-ray region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors present experimental results showing how the use of a high contrast femtosecond laser system allows better optimization of K emission from a Cu target. The shorter scale-length preformed plasma is better optimized for resonance absorption of the laser light when the laser is moved away from best focus. The experimental data show a central peak of K emission at tight focus with strong secondary peaks at large offset. The use of these secondary peaks results in a much reduced hard x-ray background and should lead to shorter K pulses than at tight focus.