47 resultados para 0-2 cm
Resumo:
Purpose: The goal of this project was to see if using IMRT to deliver elective pelvic nodal irradiation (EPNI) for prostate cancer reduced acute treatment toxicity.
Methods: Two hundred and thirty patients were enrolled into prospective trials delivering EPNI with a concomitant hypofractionated IMRT boost to the prostate. During accrual, the method of EPNI delivery changed as new literature emerged. Three methods were used (1) 4FB, (2) IMRT with 2 cm CTV margins around the pelvic vessels as suggested by Shih et al. (2005) [7] (IMRT-Shih), and (3) IMRT with nodal volumes suggested by the RTOG (IMRT-RTOG). Initially patients were treated with an empty bladder, with the remainder treated with bladder full.
Results: Patients in the 4FB group had higher rates of grade 2 acute GI toxicities compared to the IMRT-Shih and IMRT-RTOG groups (31.9% vs 20.8% vs 7.2%, p = 0.0009). Patients in the 4FB group had higher rates of grade 3 urinary frequency compared to the two IMRT groups (8.5% vs 0% vs 0%, p = 0.027). However, multivariate analysis suggested the factor that most influenced toxicity was bladder filling followed by IMRT.
Conclusions: Bladder filling appeared to be the dominant factor which predicted for acute toxicity, followed by the use of IMRT.
Resumo:
Background: In this study, the efficiency of Guar gum as a biopolymer has been compared with two other widely used inorganic coagulants, ferric chloride (FeCl3) and aluminum chloride (AlCl3), for the treatment of effluent collected from the rubber-washing tanks of a rubber concentrate factory. Settling velocity distribution curves were plotted to demonstrate the flocculating effect of FeCl3, AlCl3 and Guar gum. FeCl3 and AlCl3 displayed better turbidity removal than Guar gum at all settling velocities.
Result: FeCl3, AlCl3 and Guar gum removed 92.8%, 88.2% and 88.1% turbidity, respectively, of raw wastewater at a settling velocity of 0.1 cm min-1, respectively. Scanning electron microscopic (SEM) study conducted on the flocs revealed that Guar gum and FeCl3produced strong intercoiled honeycomb patterned floc structure capable of entrapping suspended particulate matter. Statistical experimental design Response Surface Methodology (RSM) was used to design all experiments, where the type and dosage of flocculant, pH and mixing speed were taken as control factors and, an optimum operational setting was proposed.
Conclusion: Due to biodegradability issues, the use of Guar gum as a flocculating agent for wastewater treatment in industry is highly recommended.
Resumo:
Porous layered hybrid materials have been prepared by the reaction of organo-bisphosphonate ligands, 4-(4'-phosphonophenoxy)phenylphosphonic, 4,4'-biphenylenbisphosphonic and phenylphosphonic acids, with metal(IV) cations (Zr and Sn). Crystalline Zr(IV) and Sn(IV) layered bisphosphonates were also prepared, which were non-porous. The amorphous M(IV) bisphosphonates showed variable compositions and textural properties ranging from mainly mesoporous to highly microporous solids with BET surface areas varying from 300 to 480 m(2) g(-1), micropore volumes ranging 0.10-0.20 cm(3)/g, and narrow porous size distributions for some materials. N-2 isotherms suggest that Sn(IV) derivatives show a comparatively higher micropore contribution than the Zr(IV) analogous at least for the ether-bisphosphonate hybrids. Sn(IV) bisphosphonates exhibit high microporosities without the need of using harmful DMSO as solvent. If ether-bisphosphonic acid is partially replaced by less expensive phenylphosphonic ligand, porous products are also obtained. P-31 and F-17 MAS NMR and XPS data revealed the presence of hydrogen-phosphonate groups and small (F-, Cl- and OH-) anions, which act as spacer ligands within the inorganic layers, in these hybrid materials. The complexity of the inorganic layers is higher for the Sn(IV) bisphosphonates likely due to the larger amount of small bridging anions including fluorides. It is suggested that the presence of these small inorganic ligands may be a key factor influencing both, the interaction of the inorganic layer with the bisphosphonate groups, which bridge the inorganic layers, and the generation of internal voids within a given inorganic layer. Preliminary studies of gases adsorption (H-2 and NO) have been carried out for selected Sn(IV) bisphosphonates. The H-2 adsorption capacity at 77 K and 1 bar was low, 0.26 wt%, but the NO adsorption capacity at similar to 1 bar and 298 K was relatively high, 4.2 wt%. Moreover, the hysteresis in the NO isotherms is indicative of partial strong irreversible adsorption of NO. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
Purpose: To evaluate the tamponade effect on the retina of a heavier-than-water silicone oil mixture and to compare it with the effect of silicone oil. Methods: Prospective, non-randomised, comparative pilot study. Phakic/pseudophakic patients with retinal detachment undergoing vitrectomy with Densiron 68 or silicone oil were recruited. The 'separation volume', defined as the relative volume of the space between intraocular tamponade agent and retina, was estimated using magnetic resonance imaging in both groups and compared. Results: Nine participants were included; 4 received silicone oil and 5 Densiron 68. The mean separation volume was statistically significantly larger in the silicone oil group (0.477 ± 0.419 cm ) than in the Densiron group (0.042 ± 0.013 cm ; p = 0.014). Conclusions: In this study Densiron achieved an excellent tamponade effect in the retina. © 2011 S. Karger AG, Basel.
Resumo:
A novel anode structure based on Ti mesh for the direct methanol fuel cell (DMFC) has been prepared by thermal deposition of ~5 µm PtRuO2 catalyst layer on ~50 µm Ti mesh. The preparation procedures and the main characteristics of the anode were studied by half-cell testing, scanning electron microscopy analysis, energy-dispersive X-ray measurement, and single-cell testing. The optimum calcination temperature is 450°C, calcination time is 90- 120 min, PtRuO2 catalyst loading is 5.0 mg cm-2, Pt precursor concentration range of solution is 0.14- 0.4 M, and solution aging time is 1 day. The performances of the anodes prepared using the solution kept within 20 days showed no significant difference. When it was used in DMFC feed with low-concentration methanol solution at 90°C, this new anode shows better performance than that of the conventional anode, because its thin hydrophilic structure is a benefit to the transport of methanol and carbon dioxide. However, due to its opening structure, when higher concentration methanol was employed, the performance of the cell with new anode became worse. © 2006 The Electrochemical Society. All rights reserved.
Resumo:
Linkage disequilibrium (LD) is a potentially powerful tool for the localization of disease genes for complex disorders. Most prior studies of the relationship between genetic distance and LD have examined only very short distances, focusing on the role of LD in fine-mapping and positional cloning. We examine here the relationship between marker-to-marker (M-M) LD and somewhat greater genetic distances. We analyzed 622 M-M pairings on chromosomes 6p, 8p, and 5q in 265 native Irish pedigrees ascertained for a high density of schizophrenia. LD, significant at the 5% level, was found for 96% of all M-M pairings within 0.5 cM, for 67% within 0.5-1 cM, for 35% within 1-2 cM, for 15% within 2-4 cM, for 8% within 5-10 cM, and for 7% above 10 cM. Thus, in Irish families selected for a high density of schizophrenia, M-M LD may be very common within 0.5 cM and frequent up to distances of 2 cM.
Resumo:
Purpose: In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans.
Methods: The response of the detectors to field size, dose linearity, and dose rate were assessed for 6 MV FF beams and also 6 and 10 MV FFF beams. Dosimetric and mechanical accuracy of the detector array within the Octavius 4D rotational phantom was evaluated against measurements made using semiflex and pinpoint ionization chambers, and radiochromic film. Verification FF and FFF RapidArc plans were assessed using a gamma function with 3%/3 mm tolerances and 2%/2 mm tolerances and further analysis of these plans was undertaken using film and a second detector array with higher spatial resolution.
Results: A warm-up dose of >6 Gy was required for detector stability. Dose-rate measurements were stable across a range from 0.26 to 15 Gy/min and dose response was linear, although the device overestimated small doses compared with pinpoint ionization chamber measurements. Output factors agreed with ionization chamber measurements to within 0.6% for square fields of side between 3 and 25 cm and within 1.2% for 2 x 2 cm(2) fields. The Octavius 4D phantom was found to be consistent with measurements made with radiochromic film, where the gantry angle was found to be within 0.4. of that expected during rotational deliveries. RapidArc FF and FFF beams were found to have an accuracy of >97.9% and >90% of pixels passing 3%/3 mm and 2%/2 mm, respectively. Detector spatial resolution was observed to be a factor in determining the accurate delivery of each plan, particularly at steep dose gradients. This was confirmed using data from a second detector array with higher spatial resolution and with radiochromic film.
Conclusions: The Octavius 4D phantom with associated Octavius detector 729 ionization chamber array is a dosimetrically and mechanically stable device for pretreatment verification of FF and FFF RapidArc treatments. Further improvements may be possible through use of a detector array with higher spatial resolution (detector size and/or detector spacing). (C) 2013 American Association of Physicists in Medicine.
Resumo:
Objective: To assess the seasonality of cardiovascular risk factors (CVRF) in a large set of population-based studies.
Methods: Cross-sectional data from 24 population-based studies from 15 countries, with a total sample size of 237 979 subjects. CVRFs included Body Mass Index (BMI) and waist circumference; systolic (SBP) and diastolic (DBP) blood pressure; total, high (HDL) and low (LDL) density lipoprotein cholesterol; triglycerides and glucose levels. Within each study, all data were adjusted for age, gender and current smoking. For blood pressure, lipids and glucose levels, further adjustments on BMI and drug treatment were performed.
Results: In the Northern and Southern Hemispheres, CVRFs levels tended to be higher in winter and lower in summer months. These patterns were observed for most studies. In the Northern Hemisphere, the estimated seasonal variations were 0.26 kg/m2 for BMI, 0.6 cm for waist circumference, 2.9 mm Hg for SBP, 1.4 mm Hg for DBP, 0.02 mmol/L for triglycerides, 0.10 mmol/L for total cholesterol, 0.01 mmol/L for HDL cholesterol, 0.11 mmol/L for LDL cholesterol, and 0.07 mmol/L for glycaemia. Similar results were obtained when the analysis was restricted to studies collecting fasting blood samples. Similar seasonal variations were found for most CVRFs in the Southern Hemisphere, with the exception of waist circumference, HDL, and LDL cholesterol.
Conclusions: CVRFs show a seasonal pattern characterised by higher levels in winter, and lower levels in summer. This pattern could contribute to the seasonality of CV mortality.
Resumo:
Kepler-10b was the first rocky planet detected by the Kepler satellite and confirmed with radial velocity follow-up observations from Keck-HIRES. The mass of the planet was measured with a precision of around 30%, which was
insufficient to constrain models of its internal structure and composition in detail. In addition to Kepler-10b, a second planet transiting the same star with a period of 45 days was statistically validated, but the radial velocities were only
good enough to set an upper limit of 20 M⊕ for the mass of Kepler-10c. To improve the precision on the mass for planet b, the HARPS-N Collaboration decided to observe Kepler-10 intensively with the HARPS-N spectrograph
on the Telescopio Nazionale Galileo on La Palma. In total, 148 high-quality radial-velocity measurements were obtained over two observing seasons. These new data allow us to improve the precision of the mass determination for Kepler-10b to 15%. With a mass of 3.33 ± 0.49 M⊕ and an updated radius of 1.47+0.03 −0.02 R⊕, Kepler-10b has a density of 5.8 ± 0.8 g cm−3, very close to the value predicted by models with the same internal structure and composition as the Earth. We were also able to determine a mass for the 45-day period planet Kepler-10c, with an even better precision of 11%. With a mass of 17.2 ± 1.9 M⊕ and radius of 2.35+0.09 −0.04 R⊕, Kepler-10c has a density of 7.1 ± 1.0 g cm−3. Kepler-10c appears to be the first strong evidence of a class of more massive solid planets with longer orbital periods
Resumo:
BACKGROUND & AIMS: Although observational studies have found regular aspirin use to be associated with a reduced risk of colorectal neoplasia, results from randomized trials using aspirin have been inconsistent. Dietary folate intake also has been found to be associated with a reduced risk of colorectal neoplasms in observational studies.
METHODS: A multicenter, randomized, double-blind trial of aspirin (300 mg/day) and folate supplements (0.5 mg/day) to prevent colorectal adenoma recurrence was performed using a 2 x 2 factorial design. All patients had an adenoma (>/=0.5 cm) removed in the 6 months before recruitment and were followed-up at 4-month intervals with a second colonoscopy after approximately 3 years. The primary outcome measure was a colorectal adenoma diagnosed after baseline.
RESULTS: A total of 945 patients were recruited into the study, of whom 853 (90.3%) underwent a second colonoscopy. In total, 99 (22.8%) of 434 patients receiving aspirin had a recurrent adenoma compared with 121 (28.9%) of 419 patients receiving placebo (relative risk, 0.79; 95% confidence interval [CI], 0.63-0.99). A total of 104 patients developed an advanced colorectal adenoma; 41 (9.4%) of these were in the aspirin group and 63 (15.0%) were in the placebo group (relative risk, 0.63; 95% CI, 0.43-0.91). Folate supplementation was found to have no effect on adenoma recurrence (relative risk, 1.07; 95% CI, 0.85-1.34).
CONCLUSIONS: Aspirin (300 mg/day) but not folate (0.5 mg/day) use was found to reduce the risk of colorectal adenoma recurrence, with evidence that aspirin could have a significant role in preventing the development of advanced lesions.
Resumo:
As the potassium fractional coverage of a cobalt {1010BAR} surface is increased over the range 0.2 to 0.6 monolayer the adlayer passes through a series of phase transitions. A commensurate phase is formed at exactly 0.5 monolayer, and corresponds to adatoms bonded in high-symmetry hollow sites on the unreconstructed cobalt surface, with an effective adatom radius lying between the ionic and covalent radii of potassium. A detailed structural study shows that the structural transitions can be characterised within a one-dimensional Frenkel-Kontorova model, with small lateral displacements of adatoms away from hollow sites in the low and high coverage phases. The low coverage phases progress from a distributed vacancy structure to a low density domain-wall structure; while the high coverage phase formed above half a monolayer is a high density asymmetric domain-wall structure.
Resumo:
The surface structure of the clean Co{1010BAR} surface and a c(2 x 2) potassium overlayer have been determined by quantitative low energy electron diffraction. The Co{1010BAR} sample has been shown to be laterally unreconstructed with the surface being uniquely terminated by an outermost closely packed double layer (dz12 = 0.68 angstrom). A damped oscillatory relaxation of the outermost three atomic layers occurs, with relaxations DELTA-dz12 = -6.5 +/- 2% and DELTA-dz23 = +1.0 +/- 2%.
The c(2 x 2) overlayer formed at a coverage of 0.5 ML was subjected to a full I-V analysis. A range of adsorption sites were tested including fourfold hollow, on-top, and both long and short bridge sites in combination with both "long" and "short" cobalt interlayer terminations. A clear preference was found for adsorption in the maximal coordination fourfold hollow site. No switching of surface termination occurs. The potassium adatoms reside in the [1210BAR] surface channels directly above second layer cobalt atoms with a potassium to outermost cobalt interlayer separation of 2.44 +/- 0.05 angstrom. Potassium-cobalt bond lengths of 3.40 +/- 0.05 and 3.12 +/- 0.05 angstrom between the four (one) outermost (second) layer nearest-neighbour substrate atoms suggests a potassium effective radius of 1.87 +/- 0.05 angstrom, somewhat smaller than the Pauling covalent radius and considerably larger than the ionic radius (1.38 angstrom). The alkali-surface bonding is thus predominantly "covalent"/"metallic".
Resumo:
PURPOSE: To evaluate the permanent prostate brachytherapy (PPB) learning curve using postimplant multisector dosimetric analysis and to assess the correlation between sector -specific dosimetry and patient-reported outcome measures (PROMs).
METHODS AND METHODS: First 200 patients treated with (125)I PPB monotherapy (145 Gy) at a single institution were assessed. Postimplant dosimetry (PID) using CT was evaluated for whole prostate (global) and 12 sectors, assessing minimum dose to 90% of prostate (D90) and dose to 0.1 cm(3) of rectum (D0.1cc). Global and sector PID results were evaluated to investigate changes in D90 with case number. Urinary and bowel PROMs were assessed using the International Prostate Symptom Score and the Expanded Prostate Cancer Index Composite questionnaire. The correlation between global and individual sector PID and urinary/bowel PROMs was also evaluated.
RESULTS: Linear regression confirmed a significant improvement in global D90 with case number (r(2) = 0.20; p = 0.001) at a rate of 0.11 Gy/case. Postimplant D90 of base sectors increased at a rate of 0.11-0.15 Gy/case (p = 0.0001) and matched global improvement. The regression lines of midgland and apex sectors were significantly different from global D90 (p = 0.01). Posterior midgland sectors showed a significant reduction in D90 with case number at a rate of 0.13-0.19 Gy/case (p = 0.01). Dose to posterior midgland sectors correlated with rectal D0.1cc dose but not bowel PROMs. Dose to posterior midgland sectors correlated with urinary International Prostate Symptom Score change, which was not apparent when global D90 alone was considered.
CONCLUSIONS: Sector analysis provided increased spatial information regarding the PPB learning curve. Furthermore, sector analysis correlated with urinary PROMs and rectal dose.
Resumo:
The use of wireless electrochemical promotion of catalysis (EPOC) of a Pt catalyst supported on a mixed ionic electronic conducting hollow fibre membranes is investigated. This reactor configuration offers high surface areas per unit volume and is ideally suited for scaled-up applications. The MIEC membrane used is the La 0.6Sr 0.4Co 0.2Fe 0.8O 3 perovskite (LSCF) with a Pt catalyst film deposited on the outer surface of the LSCF membrane. Experimental results showed that after initial catalyst deactivation (in the absence of an oxygen chemical potential difference across the membrane) the catalytic rate can be enhanced by using an oxygen sweep and wireless EPOC can be used for the in situ regeneration of a deactivated catalyst. © 2012 Elsevier B.V.
Resumo:
Background: Tiotropium is a once-daily, long-acting anticholinergic bronchodilator with the potential to alleviate airway obstruction in cystic fibrosis. Our objective was to evaluate the efficacy and safety of 2.5 and 5 μg once-daily tiotropium delivered via the Respimat Soft Mist Inhaler vs. placebo in people with cystic fibrosis. Methods: This phase 2, 12-week, randomized, double-blind, placebo-controlled parallel-group study of tiotropium Respimat as add-on to usual cystic fibrosis maintenance therapy included people with cystic fibrosis with pre-bronchodilator forced expiratory volume in 1 second (FEV1) ≥25% predicted. Co-primary efficacy end points were change from baseline in percent-predicted FEV1area under the curve from 0 to 4 hours (FEV1AUC0-4h), and trough FEV1at the end of week 12. Findings: A total of 510 subjects with cystic fibrosis aged 5-69 years were randomized. Both doses of tiotropium resulted in significant improvement compared with placebo in the co-primary efficacy end points at the end of week 12 (change from baseline in percent-predicted FEV1AUC0-4h: 2.5 μg: 2.94%, 95% confidence interval 1.19-4.70, p = 0.001; 5 μg: 3.39%, 95% confidence interval 1.67-5.12, p = 0.0001; in percent-predicted trough FEV1:2.5 μg: 2.24%, p = 0.2; 5 μg: 2.22%, p = 0.02). There was a greater benefit with tiotropium 5 vs. 2.5 μg. No treatment-related adverse events or unexpected safety findings were observed in patients taking tiotropium. Conclusions: Tiotropium significantly improved lung function in people with cystic fibrosis. The improvement was greater with the higher dose than the lower dose, with no difference in adverse events.