380 resultados para Pardoski, Ryan


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Bronchiectasis is characterised by a widening of the airways, leading to excess mucus production and recurrent infection. It is more prevalent in women and those in middle age. Many patients with bronchiectasis do not adhere to treatments (medications, exercise and airway clearance) prescribed for their condition. The best methods to change these adherence behaviours have not been identified.
Objectives: To assess the effects of interventions to enhance adherence to any aspect of treatment in adults with bronchiectasis in terms of adherence and health outcomes, such as pulmonary exacerbations, health-related quality of life and healthcare costs.
Search methods:We searched the Cochrane Airways Gr oup Specialised Register (CAGR), which contains trial reports identified through systematic searches of CENTRAL, MEDLINE, EMBASE, CINAHL, AMED and PsycINFO, from inception to October 2015.
Selection criteria: We planned to include randomised controlled trials (RCTs) of adults with bronchiectasis that compared any intervention aimed at enhancing adherence versus no intervention, usual care or another adherence intervention. We excluded studies of those who had bronchiectasis due to cystic fibrosis.
Data collection and analysis: Two review authors (AMcC and ET) independently screened titles, abstracts and full-texts of identified studies.
Main results: Searches retrieved 36 studies reported in 37 articles; no eligible studies were identified.
Author's Conclusions: We did not identify any studies that assessed the effect of interventions to enhance adherence to treatment in bronchiectasis. Adequately powered, well-designed trials of adherence interventions for bronchiectasis are needed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This Letter describes the development and SAR of a novel series of GlyT1 inhibitors derived from a scaffold hopping approach that provided a robust intellectual property position, in lieu of a traditional, expensive HTS campaign. Members within this new [3.1.0]​-​based series displayed excellent GlyT1 potency, selectivity, free fraction, CNS penetration and efficacy in a preclin. model of schizophrenia (prepulse inhibition)​.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rationale: Experimental studies suggest that pretreatment with b-agonists might prevent acute lung injury (ALI).

Objectives: To determine if in adult patients undergoing elective esophagectomy, perioperative treatment with inhaled b-agonists effects the development of early ALI.

Methods:We conducted a randomized placebo-controlled trial in 12 UK centers (2008-2011). Adult patients undergoing elective esophagectomy were allocated to prerandomized, sequentially numbered treatment packs containing inhaled salmeterol (100 mg twice daily) or a matching placebo. Patients, clinicians, and researchers were masked to treatment allocation. The primary outcome was development of ALI within 72 hours of surgery. Secondary outcomes were ALI within 28 days, organ failure, adverse events, survival, and health-related quality of life. An exploratory substudy measured biomarkers of alveolar-capillary inflammation and injury.

Measurements and Main Results: A total of 179 patients were randomized to salmeterol and 183 to placebo. Baseline characteristics were similar. Treatment with salmeterol did not prevent early lung injury (32 [19.2%] of 168 vs. 27 [16.0%] of 170; odds ratio [OR], 1.25; 95% confidence interval [CI], 0.71-2.22). There was no difference in organ failure, survival, or health-related quality of life.Adverse events were less frequent in the salmeterol group (55 vs. 70; OR, 0.63; 95% CI, 0.39-0.99), predominantly because of a lower number of pneumonia (7 vs. 17; OR, 0.39; 95% CI, 0.16-0.96). Salmeterol reduced some biomarkers of alveolar inflammation and epithelial injury.

Conclusion: Perioperative treatment with inhaled salmeterol was well tolerated but did not prevent ALI.

Clinical trial registered with International Standard Randomized Controlled Trial Register (ISRCTN47481946) and European Union database of randomized Controlled Trials (EudraCT 2007-004096-19).Copyright © 2014 by the American Thoracic Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To create, implement, and evaluate debate as a method of teaching pharmacy undergraduate students about ethical issues.

Design. Debate workshops with 5 hours of contact with student peers and facilitators and 5 hours of self-study were developed for second-year pharmacy students. Student development of various skills and understanding of the topic were assessed by staff members and student peers.

Assessment. One hundred fifty students completed the workshops. The mean score for debating was 25.9 out of 30, with scores ranging from 23.2 to 28.7. Seventy percent of students agreed that the debates were a useful teaching method in the degree program.

Conclusion. A series of workshops using debates effectively delivered course content on ethical issues and resulted in pharmacy students developing skills such as teamwork, peer assessment, communication, and critical evaluation. These findings suggest that pharmacy students respond favorably to a program using debates as a teaching tool.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The emerging field of microneedle-based minimally invasive patient monitoring and diagnosis is reviewed. Microneedle arrays consist of rows of micron-scale projections attached to a solid support. They have been widely investigated for transdermal drug and vaccine delivery applications since the late 1990s. However, researchers and clinicians have recently realized the great potential of microneedles for extraction of skin interstitial fluid and, less commonly, blood, for enhanced monitoring of patient health.

Methods: We reviewed the journal and patent literature, and summarized the findings and provided technical insights and critical analysis.

Results: We describe the basic concepts in detail and extensively review the work performed to date.

Conclusions: It is our view that microneedles will have an important role to play in clinical management of patients and will ultimately improve therapeutic outcomes for people worldwide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe, for the first time, quantification of in-skin swelling and fluid uptake by hydrogel-forming microneedle (MN) arrays and skin barrier recovery in human volunteers. Such MN arrays, prepared from aqueous blends of hydrolyzed poly(methylvinylether/maleic anhydride) (15%, w/w) and the cross-linker poly(ethyleneglycol) 10,000 Da (7.5%, w/w), were inserted into the skin of human volunteers (n = 15) to depths of approximately 300 μm by gentle hand pressure. The MN arrays swelled in skin, taking up skin interstitial fluid, such that their mass had increased by approximately 30% after 6 h in skin. Importantly, however, skin barrier function recovered within 24 h after MN removal, regardless of how long the MN had been in skin or how much their volume had increased with swelling. Further research on closure of MN-induced micropores is required because transepidermal water loss measurements suggested micropore closure, whereas optical coherence tomography indicated that MN-induced micropores had not closed over, even 24 h after MN had been removed. There were no complaints of skin reactions, adverse events, or strong views against MN use by any of the volunteers. Only some minor erythema was noted after patch removal, although this always resolved within 48 h, and no adverse events were present on follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To explore children's views on microneedle use for this population, particularly as an alternative approach to blood sampling, in monitoring applications, and so, examine the acceptability of this approach to children.

Methods: Focus groups were conducted with children (aged 10-14 years) in a range of schools across Northern Ireland. Convenience sampling was employed, i.e. children involved in a university-directed community-outreach project (Pharmacists in Schools) were recruited.

Key findings: A total of 86 children participated in 13 focus groups across seven schools in Northern Ireland. A widespread disapproval for blood sampling was evident, with pain, blood and traditional needle visualisation particularly unpopular aspects. In general, microneedles had greater visual acceptability and caused less fear. A patch-based design enabled minimal patient awareness of the monitoring procedure, with personalised designs, e.g. cartoon themes, favoured. Children's concerns included possible allergy and potential inaccuracies with this novel approach; however, many had confidence in the judgement of healthcare professionals if deeming this technique appropriate. They considered paediatric patient education critical for acceptance of this new approach and called for an alternative name, without any reference to 'needles'.

Conclusions: The findings presented here support the development of blood-free, minimally invasive techniques and provide an initial indication of microneedle acceptability in children, particularly for monitoring purposes. A proactive response to these unique insights should enable microneedle array design to better meet the needs of this end-user group. Further work in this area is recommended to ascertain the perspectives of a purposive sample of children with chronic conditions who require regular monitoring. © 2013 Royal Pharmaceutical Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate, for the first time, the influence of pharmacist intervention and the use of a patient information leaflet on self-application of hydrogel-forming microneedle arrays by human volunteers without the aid of an applicator device.
Methods: A patient information leaflet was drafted and pharmacist counselling strategy devised. Twenty human volunteers applied 11 × 11 arrays of 400 μm hydrogel-forming microneedle arrays to their own skin following the instructions provided. Skin barrier function disruption was assessed using transepidermal water loss measurements and optical coherence tomography and results compared to those obtained when more experienced researchers applied the microneedles to the volunteers or themselves.
Results: Volunteer self-application of the 400 μm microneedle design resulted in an approximately 30% increase in skin transepidermal water loss, which was not significantly different from that seen with self-application by the more experienced researchers or application to the volunteers. Use of optical coherence tomography showed that self-application of microneedles of the same density (400 μm, 600 μm and 900 μm) led to percentage penetration depths of approximately 75%, 70% and 60%, respectively, though the diameter of the micropores created remained quite constant at approximately 200 μm. Transepidermal water loss progressively increased with increasing height of the applied microneedles and this data, like that for penetration depth, was consistent, regardless of applicant.
Conclusion: We have shown that hydrogel-forming microneedle arrays can be successfully and reproducibly applied by human volunteers given appropriate instruction. If these outcomes were able to be extrapolated to the general patient population, then use of bespoke MN applicator devices may not be necessary, thus possibly enhancing patient compliance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the Pan-STARRS Moving Object Processing System (MOPS), a modern software package that produces automatic asteroid discoveries and identifications from catalogs of transient detections from next-generation astronomical survey telescopes. MOPS achieves >99.5% efficiency in producing orbits from a synthetic but realistic population of asteroids whose measurements were simulated for a Pan-STARRS4-class telescope. Additionally, using a nonphysical grid population, we demonstrate that MOPS can detect populations of currently unknown objects such as interstellar asteroids. MOPS has been adapted successfully to the prototype Pan-STARRS1 telescope despite differences in expected false detection rates, fill-factor loss, and relatively sparse observing cadence compared to a hypothetical Pan-STARRS4 telescope and survey. MOPS remains highly efficient at detecting objects but drops to 80% efficiency at producing orbits. This loss is primarily due to configurable MOPS processing limits that are not yet tuned for the Pan-STARRS1 mission. The core MOPS software package is the product of more than 15 person-years of software development and incorporates countless additional years of effort in third-party software to perform lower-level functions such as spatial searching or orbit determination. We describe the high-level design of MOPS and essential subcomponents, the suitability of MOPS for other survey programs, and suggest a road map for future MOPS development.