491 resultados para Ophthalmology.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose . To investigate alternative surgical method to cover subconjunctival portion of the tube in tube shunt surgery in glaucoma Methods. In thirteen eyes of twelve patients who underwent tube shunt surgery at WEH between July 1991 to November 1996 a "rotating" autologous scleral lamellar graft was created to cover the subconjuctival course of the tube. These patients were followed for clinical signs of conjuctival breakdown, graft melt, tube erosion, anterior staphylomas, graft related inflammation, infections or graft related complications. Results. The patients were followed up for a mean of 16 5 months( range 1-60 months). All eyes tolerated the autologous graft well without any clinical evidence of tube erosions, graft melting , graft related or intraocular inflammation Conclusions The use of autologous sciera, to cover the tube in a tube shunt procedure appears to be effective and without inappropriate short term risk. It offers the advantages of availability , lower cost, and eliminates the potential risk of transmission of infectious disease( i.e. slow-virus, HIV etc.).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Therapeutic strategies aimed to reverse the pathogenic process, replace diseased tissue, and restore visual function represent the final frontier in treatment of chronic ocular disease. The goal in this approach is improvement, not stabilization or slowing the decline of the disease. Lines of research that can lead to identification of new treatments that could reverse the disease course are reviewed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the quality of reporting of all diagnostic studies published in five major ophthalmic journals in the year 2002 using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative parameters. Methods: Manual searching was used to identify diagnostic studies published in 2002 in five leading ophthalmic journals, the American Journal of Ophthalmology (AJO), Archives of Ophthalmology (Archives), British Journal of Ophthalmology (BJO), Investigative Ophthalmology and Visual Science (IOVS), and Ophthalmology. The STARD checklist of 25 items and flow chart was used to evaluate the quality of each publication. Results: A total of 16 publications were included (AJO = 5, Archives = 1, BJO = 2, IOVS = 2, and Ophthalmology = 6). More than half of the studies (n = 9) were related to glaucoma diagnosis. Other specialties included retina (n = 4) cornea (n = 2), and neuro-ophthalmology (n = 1). The most common description of diagnostic accuracy was sensitivity and specificity values, published in 13 articles. The number of fully reported items in evaluated studies ranged from eight to 19. Seven studies reported more than 50% of the STARD items. Conclusions: The current standards of reporting of diagnostic accuracy tests are highly variable. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the new millennium anesthetic agents will be safer and more efficient. Topical anesthesia will be the most frequently used technique. Time- and cost-saving measures will expand the current trend of outpatient surgery and anesthesia will be reduced. Patients' perioperative comfort will improve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sensitivity and specificity of the screening mode of the Humphrey-Welch Allyn frequency-doubling technology (FDT), Octopus tendency-oriented perimetry (TOP), and the Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast (HSF) in patients with glaucoma. DESIGN: A comparative consecutive case series. METHODS: This was a prospective study which took place in the glaucoma unit of an academic department of ophthalmology. One eye of 70 consecutive glaucoma patients and 28 age-matched normal subjects was studied. Eyes were examined with the program C-20 of FDT, G1-TOP, and 24-2 HSF in one visit and in random order. The gold standard for glaucoma was presence of a typical glaucomatous optic disk appearance on stereoscopic examination, which was judged by a glaucoma expert. The sensitivity and specificity, positive and negative predictive value, and receiver operating characteristic (ROC) curves of two algorithms for the FDT screening test, two algorithms for TOP, and three algorithms for HSF, as defined before the start of this study, were evaluated. The time required for each test was also analyzed. RESULTS: Values for area under the ROC curve ranged from 82.5%-93.9%. The largest area (93.9%) under the ROC curve was obtained with the FDT criteria, defining abnormality as presence of at least one abnormal location. Mean test time was 1.08 ± 0.28 minutes, 2.31 ± 0.28 minutes, and 4.14 ± 0.57 minutes for the FDT, TOP, and HSF, respectively. The difference in testing time was statistically significant (P <.0001). CONCLUSIONS: The C-20 FDT, G1-TOP, and 24-2 HSF appear to be useful tools to diagnose glaucoma. The test C-20 FDT and G1-TOP take approximately 1/4 and 1/2 of the time taken by 24 to 2 HSF. © 2002 by Elsevier Science Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Guarded filtration surgery is commonly used to control the intraocular pressure (IOP) in glaucomatous patients. Filtration surgery lowers the IOP by creating a fistula between the inner compartments of the eye and the subconjunctival space (i.e., filtering bleb). There are several options to improve the function of filtering blebs and to prevent their failure. However, improvement of IOP control after guarded filtration procedures is associated with a higher frequency of bleb-related complications. Early (e.g., bleb leak, excessive filtration, flat anterior chamber, filtration failure) and late (e.g., bleb leak, excessive filtration and hypotony, symptomatic blebs, bleb encapsulation, filtration failure, bleb infection) complications associated with filtering procedures should be managed adequately to prevent further problems. Techniques to improve the function of filtering blebs and to treat postoperative complications have progressed over the past decade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Recent National Institute of Clinical Excellence guidance suggests primary surgery should be offered to patients presenting with glaucoma with severe visual field loss. We undertook a survey of UK consultant ophthalmologists to determine if this represents current practice and explore attitudes towards managing patients with advanced glaucoma at presentation.

DESIGN: Questionnaire evaluation study.

PARTICIPANTS: All consultant ophthalmologists currently practicing in the UK.

METHODS: A single-page questionnaire was posted to all consultants (n = 910) currently practicing in the UK along with a pre-paid return envelope. A second questionnaire was sent to non-responders (n = 459).

MAIN OUTCOME MEASURES: Questionnaire responses.

RESULTS: 626 responses were received representing 68.8% of the population surveyed. 152 (24%) volunteered a specialist interest in glaucoma. Consensus opinion for both glaucoma specialists (64.9%) and non-glaucoma specialists (62.4%) was to start with primary medical therapy, most commonly citing surgical risk as the primary reason (23% and 22%, respectively) for this approach. Most felt the highest intraocular pressure measurement during follow up (measured in clinic) was the most important variable for prevention of further visual loss (60% of glaucoma specialists and 55% of non-glaucoma specialists). Eighty-three per cent of all responders suggested they would change their practice if evidence supporting primary surgery as a safe and more effective approach existed.

CONCLUSIONS: Recent National Institute of Clinical Excellence guidance does not reflect the current management approach of UK ophthalmologists. The primary concern was related to potential complications of surgery although most practitioners would be willing to change their practice if evidence existed supporting primary surgery in patients presenting with advanced glaucoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the effect of cataract surgery on frequency doubling technology (FDT) perimetry in patients with coexisting cataract and glaucoma. Methods: In this consecutive prospective cohort study 27 patients with open angle glaucoma scheduled for cataract extraction alone or combined with trabeculectomy were enrolled. All patients underwent FDT threshold C-20 visual fields within 3 months before and 3 months after surgery. Changes in mean deviation (MD) and pattern standard deviation (PSD) were evaluated. Additionally, changes in best corrected logMAR visual acuity (VA), intraocular pressure (IOP), and number of glaucoma medications were also studied. Results: 22 patients completed the study. VA improved after surgery, from 0.47 (SD 0.19) to 0.12 (0.17) (p

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim - To report the outcome of a series of patients with stem cell deficiency who underwent allo-limbal transplantation and to describe a technique for this procedure. Methods - Six consecutive patients underwent allo-limbal stem cell transplantation. The primary diagnosis included alkali burn (n = 2), trachoma (n = 1), chronic rosacea blepharitis and keratoconjunctivitis (n = 1), aniridia (n = 1), and Stevens-Johnson syndrome (n = 1). The limbal rim consisted of peripheral cornea and perilimbal sclera, FK-506 was used postoperatively for immunosuppression. Results - The length of follow up ranged from 3 to 24 months (mean follow up 11.8 (SD 9.3) months). The outcome was considered satisfactory in five of six cases. The corneal surface was completely epithelialised within 2 weeks, and there was a substantial improvement in vision and symptoms. One patient had recurrent epithelial defects related to eyelid abnormalities. No side effects associated with systemic immunosuppression were noted. Conclusion - Allo-limbal transplantation, with systemic immunosuppression with FK-506 is useful in reconstruction of the ocular surface with improvement in vision in patients with severe stem cell deficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent advances in corneal graft technology, including donor tissue retrieval, storage and surgical techniques, have greatly improved the clinical outcome of corneal grafts. Despite these advances, immune mediated corneal graft rejection remains the single most important cause of corneal graft failure. Several host factors have been identified as conferring a "high risk" status to the host. These include: more than two quadrant vascularisation, with associated lymphatics, which augment the afferent and efferent arc of the immune response; herpes simplex keratitis; uveitis; silicone oil keratopathy; previous failed (rejected) grafts; "hot eyes"; young recipient age; and multiple surgical procedures at the time of grafting. Large grafts, by virtue of being closer to the host limbus, with its complement of vessels and antigen-presenting Langerhans cells, also are more susceptible to rejection. The diagnosis of graft rejection is entirely clinical and in its early stages the clinical signs could be subtle. Graft rejection is largely mediated by the major histocompatibility antigens, minor antigens and perhaps blood group ABO antigens and some cornea-specific antigens. Just as rejection is mediated by active immune mediated events, the lack of rejection (tolerance) is also sustained by active immune regulatory mechanisms. The anterior chamber associated immune deviation (ACAID) and probably, conjunctiva associated lymphoid tissue (CALT) induced mucosal tolerance, besides others, play an important role. Although graft rejection can lead to graft failure, most rejections can be readily controlled if appropriate management is commenced at the proper time. Topical steroids are the mainstay of graft rejection management. In the high-risk situations however, systemic steroids, and other immunosuppressive drugs such as cyclosporin and tacrolimus (FK506) are of proven benefit, both for treatment and prevention of rejection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of socio-economic factors on severity of glaucoma at presentation

METHODS: All newly diagnosed glaucoma patients at the University Hospitals-NHS, Aberdeen and South Glasgow University Hospitals-NHS, in 2006, were included. Glaucoma was severe at presentation if there was a repeatable visual-field loss with a mean deviation index greater than 12 dB in the Humphreys visual fields test or an absolute paracentral scotoma within the central 5 degrees of the visual fields. Home address was used to determine the Scottish Index of Multiple Deprivation (SIMD) rank. The SIMD rank, demographics and severity of glaucoma at presentation were investigated using general linear modelling.

RESULTS: There were 48 patients with severe glaucoma and 74 patients with non-severe glaucoma. In four, the severity could not be determined. Severity of glaucoma at presentation was significantly associated with SIMD rank, being most severe in patients from areas with the lowest ranks (p = 0.026). Age was a significant factor (p = 0.024), with severe glaucoma being more common in elderly patients.

CONCLUSIONS: Age and socio-economic deprivation were associated with severity of glaucoma at presentation, with patients from areas of higher socio-economic deprivation presenting with more advanced glaucoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To evaluate the efficacy and safety of intraoperative mitomycin C (MMC) in eyes undergoing Ahmed Glaucoma Valve implantation. Design Randomized controlled clinical trial. Participants Sixty patients with refractory glaucoma. Intervention Sixty eyes of 60 patients with refractory glaucoma were randomized to receive intraoperative MMC (0.5 mg/ml for 5 minutes) (n = 34) or balanced salt solution (n = 26) during Ahmed Glaucoma Valve implantation. Main outcome measures Surgical success was defined according to 2 different criteria: (1) postoperative intraocular pressure (IOP) between 6 and 21 mmHg, with or without antiglaucoma medications, and (2) IOP reduction of at least 30% relative to preoperative values. Eyes requiring additional glaucoma surgery, developing phthisis, or showing loss of light perception were classified as failures. Success rates in both groups were compared using Kaplan-Meier survival curves and the log rank test. Other outcome measures were mean IOP, number of glaucoma medications, and complications. Results After a mean follow-up of 12.3 months, Kaplan-Meier survival analysis showed a probability of success of 59% at 18 months for the MMC group and 61% for the control group when the first criterion for success was used (IOP between 6 and 21 mmHg). When an IOP reduction of at least 30% was used as the criterion to define success, the Kaplan-Meier survival analysis demonstrated a probability of success at 18 months of 62% for the MMC group and 67% for the control group. There were no significant differences in survival rates between the 2 groups with either criterion (P = 0.75 and P = 0.37, respectively). After 15 days postoperatively, the mean IOP did not significantly differ for both MMC and control eyes. Mean numbers of postoperative antiglaucoma medications were similar in MMC-treated eyes and controls. There was no significant difference between the incidences of postoperative complications in both groups. Conclusion Mitomycin C did not increase the short- or intermediate-term success rates of Ahmed Glaucoma Valve implantation. © 2004 by the American Academy of Ophthalmology.