Purpose. To evaluate the effects of a YAG laser posterior capsulotomy on intraocular pressure (IOP) in glaucoma patients. Methods. We retrospectively studied 69 patients who underwent posterior capsulotomy following cataract or combined cataract-glaucoma surgery and who had a minimum follow-up of six months. We assessed IOP control, number of glaucoma medications required, and need for additional glaucoma surgery following capsulotomy as clinical outcomes. We defined an "unfavorable result" as: a =5 mm Hg sustained rise in IOP, a need for additional glaucoma medications, and/or a need for additional glaucoma surgery. We calculated Kaplan-Meier event rate curves for these "unfavorable results." Mean follow-up was 24.4 ± 12.3 months. Results. 6.3% of patients had an IOP rise of =5 mm Hg one hour post capsulotomy. The actuarial (Kaplan-Meier) rate of any "unfavorable result" was 11.6% at 4 months, 38.1% at 12 months, 46.1% at 24 months, and 52.1% at 36 months following capsulotomy. Conclusions. Progression of glaucoma after YAG capsulotomy is common and may be accelerated by the laser procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To evaluate the diagnostic capability of tendency oriented perimetry (TOP) in glaucoma. METHODS. A): The diagnostic accuracy of mean defect (MD), square-root of the loss variance (sLV), and number of pathologic points (NPP) was calculated in 295 normal and 414 glaucoma eyes (179 early, 112 moderate, and 123 advanced) examined with TOP. B): Threshold fluctuation (F) and its relationship with the loss variance (LV) was measured in 34 normal and 33 glaucoma eyes (mean MD=3 dB; SD=3.9) for TOP and for full-threshold perimetry (FT). C): Twenty-eight eyes with stable glaucoma (mean MD=9.5 dB; SD=7.2) were examined six times to quantify LV error. D): TOP and FT were tested with the simulation program PeriSim using different behavior models. RESULTS. A): The best diagnostic index in early glaucoma (MD

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims - To evaluate the outcome of filtering procedures supplemented with mitomycin C in children with glaucoma. Methods - All patients aged 17 or younger with glaucoma who underwent filtering surgery supplemented with mitomycin C at a tertiary care centre (n = 21) during a 5 year interval (1992 and 1996) were included. One eye for each patient was entered into the analysis. The postoperative intraocular pressure (IOP), use of antiglaucoma medications, clinical stability of glaucoma, complications, and visual acuity were retrospectively evaluated. Kaplan-Meier survival curves were used to estimate the probability of success. Results - At the time of surgery mean age was 5.7 (SD 5.0) years. The most common diagnoses were trabeculodysgenesis (n = 6) and aphakic glaucoma (n = 8). Mean IOP before surgery was 35.7 (10.5) mmHg. Average length of follow up was 18.6 (14.7) months. The probability of having IOP less than 21 mmHg with no antiglaucoma medications and with clinically stable glaucoma 1 year after surgery was 76.9% in phakic eyes (n = 13) and 0% in aphakic eyes (n = 8). A phakic patient with Sturge-Weber's syndrome had choroidal effusion after surgery that resolved spontaneously. In the aphakic group one patient had retinal detachment and another developed an encapsulated bleb. Visual acuity deteriorated in one patient. Conclusion - A guarded filtration procedure with mitomycin C is relatively successful in phakic children with glaucoma, but unsuccessful in aphakic ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report an unusual case of horizontal corneal Descemet's membrane break due to birth trauma. The patient had a difficult birth with trauma to her right eye and poor vision. However unlike the reports in literature, which describe these breaks to have a characteristic vertical or vertically oblique orientation in birth trauma, the breaks in our patient were horizontal. No other cause was found for these Descemet's breaks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glaucoma is characterized by a typical appearance of the optic disc and peripheral visual field loss. However, diagnosis may be challenging even for an experienced clinician due to wide variability among normal and glaucomatous eyes. Standard automated perimetry is routinely used to establish the diagnosis of glaucoma. However, there is evidence that substantial retinal ganglion cell damage may occur in glaucoma before visual field defects are seen. The introduction of newer imaging devices such as confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography for measuring structural changes in the optic nerve head and retinal nerve fiber layer seems promising for early detection of glaucoma. New functional tests may also help in the diagnosis. However, there is no evidence that a single measurement is superior to the others and a combination of tests may be needed for detecting early damage in glaucoma. © 2010 Expert Reviews Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: To investigate the visual outcome of glaucoma patients.

DESIGN: This is a retrospective study of case notes of patients who died while under follow up in a glaucoma clinic of a University Hospital in Scotland between 2006 and 2009.

PARTICIPANTS: Seventy-seven patients were identified.

METHODS: Data collected included type of glaucoma, coexisting pathology and best-corrected visual acuity in Snellen (converted to decimal values) for the first and final clinic visit. The final visual status was evaluated based on the best-corrected visual acuity of the better seeing eye at the last glaucoma clinic visit. Patients who had best-corrected visual acuity of less than Snellen decimal 0.5 were considered not to meet the standards for driving.

MAIN OUTCOME MEASURES: Snellen decimal best-corrected visual acuity, fulfilment of driving standards, and eligibility for partial sight and blind registration at the last clinic visit.

RESULTS: The mean ages at presentation and death were 71.8 ± 10.3 years and 82.2 ± 8.7 years respectively. The mean Snellen decimal best-corrected visual acuity of the better eye at presentation was 0.78, and at the final clinic visit was 0.61. At the final clinic visit, no patients were partial sight registrable, four (5.2%) were blind registrable, and 27 (35.1%) did not fulfil UK driving criteria. Glaucoma patients with other ocular pathologies were more likely to fail UK driving criteria at presentation (P = 0.02) and at last clinic visit (P = 0.03).

CONCLUSION: The majority of glaucoma patients maintained good visual function at the end of their lifetime.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To determine the agreement between observers in estimating the configuration of the human anterior chamber angle (ACA) using ultrasound biomicroscopy (UBM). Methods. Two masked clinicians used UBM images to estimate, in 41 eyes, the configuration of the ACA, especially (1) the position of contact between the peripheral iris and the inside of the eye wall, (2) the angularity of the approach to the ACA, and (3) the curvature of the peripheral iris. Agreement between observers was evaluated by the kappa statistic. Results. Inter-observer agreement in assessing the iris insertion (kappa = 0.79), angular width (Kappa = 0.95), and the peripheral iris curvature (kappa = 0.84) was high. Conclusions. The agreement between observers in evaluating the anterior chamber angle configuration by UBM was excellent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 42-year-old man has been under long-term follow-up since he was a child for congenital glaucoma and buphthalmos in both eyes. His left eye best corrected visual acuity (BCVA) was counting fingers, due to end-stage glaucoma. He was on maximal medical therapy with an intraocular pressure (IOP) maintained at mid to low twenties. His right eye, the only seeing eye, had a BCVA of 6/9. This eye had undergone multiple glaucoma laser and surgical procedures, including an initial first Molteno drainage device inserted superonasally that failed in April 2003 due to fibrotic membrane over the tube opening. As a result, he subsequently had a second Molteno drainage device inserted inferotemporally. To further maximize his vision he had an uncomplicated cataract extraction and intraocular lens implant in December 2004, after which he developed postoperative cystoid macular edema and corneal endothelial failure. He underwent a penetrating keratoplasty in the right eye thereafter in March 2007. After approximately a year, the second Molteno device developed drainage tube retraction, which was managed surgically to maintain optimum IOP in the right eye. His right eye vision to date is maintained at 6/12. © 2011 Mustafa and Azuara-Blanco.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims - To study the interchangeability of the measurements of the optic disc topography obtained by one computerised image analyser and one confocal laser tomographic scanner. Methods - One eye of 28 patients with glaucoma or glaucoma suspects was studied. All cases had simultaneous stereoscopic disc photographs taken with the fundus camera Topcon TRC-SS and optic disc examination with the Heidelberg retina tomograph (HRT) during the same visit. The optic disc photographs were digitised and analysed with the Topcon ImageNet (TI) system. Three variables of the optic disc topography provided by the TI and the HRT were compared - cup volume (CV), rim area (RA), and cup area to disc area ratio (CA/DA). Results - The mean values of CV and RA provided by the TI (0.52 (SD 0.32) mm and 1.58 (0.39) mm , respectively) were greater (p <0.01) than the mean values of CV and RA determined by the HRT (0.32 (0.25) mm , and 1.33 (0.47) mm , respectively). The mean value of CA/DA provided by the TI (0.42 (0.14)) and the HRT (0.42 (0.18)) was similar (p = 0.93). Correlation coefficients between measurements obtained by the two methods ranged from 0.53 to 0.73. Conclusion - There was a significant discrepancy in the measurements of rim area and cup volume of the optic disc obtained by a computerised image analyser and a laser scanning tomograph.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. Scanning laser tomography with the Heidelberg retina tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the HRT for diagnosing glaucoma. METHODS. A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the HRT for glaucoma was performed. Two reviewers selected and appraised the papers independently. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS. A total of 29 articles were included. Interobserver rating agreement was observed in 83% of items (? = 0.76). The number of STARD items properly reported ranged from 5 to 18. Less than a third of studies (7/29) explicitly reported more than half of the STARD items. Descriptions of key aspects of the methodology were frequently missing. For example, the design of the study (prospective or retrospective) was reported in 6 of 29 studies, and details of participant sampling (e.g., consecutive or random selection) were described in 5 of 29 publications. The commonest description of diagnostic accuracy was sensitivity and specificity (25/29) followed by area under the ROC curve (13/29), with 9 of 29 publications reporting both. CONCLUSIONS. The quality of reporting of diagnostic accuracy tests for glaucoma with HRT is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. Copyright © Association for Research in Vision and Ophthalmology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Resource utilisation and direct costs associated with glaucoma progression in Europe are unknown. As population progressively ages, the economic impact of the disease will increase. Methods: From a total of 1655 consecutive cases, the records of 194 patients were selected and stratified by disease severity. Record selection was based on diagnoses of primary open angle glaucoma, glaucoma suspect, ocular hypertension, or normal tension glaucoma; 5 years minimum follow up were required. Glaucoma severity was assessed using a six stage glaucoma staging system based on static threshold visual field parameters. Resource utilisation data were abstracted from the charts and unit costs were applied to estimate direct costs to the payer. Resource utilisation and estimated direct cost of treatment, per person year, were calculated. Results: A statistically significant increasing linear trend (p = 0.018) in direct cost as disease severity worsened was demonstrated. The direct cost of treatment increased by an estimated €86 for each incremental step ranging from €455 per person year for stage 0 to €969 per person year for stage 4 disease. Medication costs ranged from 42% to 56% of total direct cost for all stages of disease. Conclusions: These results demonstrate for the first time in Europe that resource utilisation and direct medical costs of glaucoma management increase with worsening disease severity. Based on these findings, managing glaucoma and effectively delaying disease progression would be expected to significantly reduce the economic burden of this disease. These data are relevant to general practitioners and healthcare administrators who have a direct influence on the distribution of resources.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study is to describe the ocular and demographic features of Caucasian patients newly presenting with primary angle closure glaucoma and the proportion of workload it represents at a tertiary university hospital glaucoma service. Methods: A retrospective case notes review was conducted for all Caucasian patients newly diagnosed with narrow angles, primary angle closure, acute primary angle closure and primary angle closure glaucoma that were seen over a period of 2 years. Demographic and ocular variables were compared and statistical analysis was carried out with the paired t -test and chi-squared test. Number of primary open angle closure glaucoma and acute angle closure cases were compared with total number of new referrals to the department, new patients diagnosed with glaucoma and population numbers for the North East of Scotland. Results: One hundred and four patients were analysed. Twenty-four (23.1%) had narrow angles, 30 (28.8%) had primary angle closure and 50 (48.1%) had primary angle closure glaucoma. Twelve (11.5%) presented with acute primary angle closure. There was no significant difference for gender, age, hypermetropia or visual acuity between groups. Primary angle closure glaucoma constituted 22.9% (50/128) of newly diagnosed glaucoma cases. Based on the 2001 Scotland census, the crude annual incidence of newly diagnosed primary angle closure glaucoma was estimated at 14.8 per 100000 and 3.6 per 100000 for acute primary angle closure in the over-45-year-old population. Conclusion: Our study confirms that primary angle closure glaucoma is uncommon in Caucasians, but not as rare as originally perceived as it makes up a fair proportion (22.9%) of glaucoma workload. © 2009 The Authors Journal Compilation © 2009 Royal Australian and New Zealand College of Ophthalmologists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the clinical agreement in the detection of optic disk changes in patients with glaucoma using simultaneous stereophotographs. DESIGN: Masked-observer variability study. METHODS: Ten glaucoma specialists examined pairs of simultaneous stereophotographs of glaucomatous and control optic disks to determine whether there were changes compatible with progression of glaucomatous damage. RESULTS: Intraobserver agreement had a kappa value ranging from 0.55 to 0.78. Interobserver agreement among the glaucoma specialists had a kappa value ranging from 0.34 to 0.68. CONCLUSION: Clinical examination of stereophotographs to detect optic disk changes in glaucoma patients has limitations associated with suboptimal reproducibility. © 2003 by Elsevier Inc. All rights reserved.