86 resultados para volumetric shrinkage
Resumo:
A phantom was designed and implemented for the delivery of treatment plans to cells in vitro. Single beam, 3D-conformal radiotherapy (3D-CRT) plans, inverse planned five-field intensity-modulated radiation therapy (IMRT), nine-field IMRT, single-arc volumetric modulated arc therapy (VMAT) and dual-arc VMAT plans were created on a CT scan of the phantom to deliver 3 Gy to the cell layer and verified using a Farmer chamber, 2D ionization chamber array and gafchromic film. Each plan was delivered to a 2D ionization chamber array to assess the temporal characteristics of the plan including delivery time and 'cell's eye view' for the central ionization chamber. The effective fraction time, defined as the percentage of the fraction time where any dose is delivered to each point examined, was also assessed across 120 ionization chambers. Each plan was delivered to human prostate cancer DU-145 cells and normal primary AGO-1522b fibroblast cells. Uniform beams were delivered to each cell line with the delivery time varying from 0.5 to 20.54 min. Effective fraction time was found to increase with a decreasing number of beams or arcs. For a uniform beam delivery, AGO-1552b cells exhibited a statistically significant trend towards increased survival with increased delivery time. This trend was not repeated when the different modulated clinical delivery methods were used. Less sensitive DU-145 cells did not exhibit a significant trend towards increased survival with increased delivery time for either the uniform or clinical deliveries. These results confirm that dose rate effects are most prevalent in more radiosensitive cells. Cell survival data generated from uniform beam deliveries over a range of dose rates and delivery times may not always be accurate in predicting response to more complex delivery techniques, such as IMRT and VMAT.
Resumo:
We present a study on the effect of the alkyl chain length of the imidazolium ring in 1-alkyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ionic liquids, [C1CnIm][NTf2] (n = 2 to 10), on the mixing properties of (ionic liquid + alcohol) mixtures (enthalpy and volume). We have measured small excess molar volumes with highly asymmetric curves as a function of mole fraction composition (S-shape) with more negative values in the alcohol-rich regions. The excess molar volumes increase with the increase of the alkyl-chain length of the imidazolium cation of the ionic liquid. The values of the partial molar excess enthalpy and the enthalpy of mixing are positive and, for the case of methanol, do not vary monotonously with the length of the alkyl side-chain of the cation on the ionic liquid – increasing from n = 2 to 6 and then decreasing from n = 8. This non-monotonous variation is explained by a more favourable interaction of methanol with the cation head group of the ionic liquid for alkyl chains longer than eight carbon atoms. It is also observed that the mixing is less favourable for the smaller alcohols, the enthalpy of mixing decreasing to less positive values as the alkyl chain of the alcohol increases. Based on the data from this work and on the knowledge of the vapour pressure of {[C1CnIm][NTf2] + alcohol} binary mixtures at T = 298 K reported in the literature, the excess Gibbs free energy, excess enthalpy and excess entropy could be then calculated and it was observed that these mixtures behave like the ones constituted by a non-associating and a non-polar component, with its solution behaviour being determined by the enthalpy.
Resumo:
Densities (F), viscosities (?), and isobaric heat molar capacities (Cp) of binary mixtures containing imidazolium octanoate, [Im][C7CO2], a protic ionic liquid (PIL), with four molecular solvents, water, acetonitrile, ethanol, and 1-octanol, are determined as a function of temperature from (298.15 to 323.15) K and within the whole composition range at atmospheric pressure. Excess molar volumes, VE, excess molar heat capacities, Cp E, and the deviation from additivity rules of viscosities, ??, of imidazolium octanoate solutions were then deduced from the experimental results, as well as apparent molar volumes, Vfi, and partial molar volumes, V j m,i. Results are discussed according to the nature of the interaction between the PIL and the molecules and the effect of temperature. The excess Gibbs energies of activation of viscous flow (?G*E) for these systems were then calculated at 298.15 K. The excess isobaric heat capacities, Cp E, of binary ([Im][C7CO2] + solvent) systems, depend also of the nature of the molecular solvent in mixture. The excess properties were then correlated, at each temperature, as a function of composition by a Redlich-Kister-type equation. Finally results have been discussed in terms of molecular interactions and molecular structures in these binary mixtures, and thermodynamic properties of investigated binary mixtures were then compared to literature values together to investigate the impact of the nature of the solvent on these reported properties.
Resumo:
Densities ([rho]) and viscosities ([eta]) of binary mixtures containing the Protic Ionic Liquid (PIL), pyrrolidinium octanoate with five molecular solvents: water, methanol, ethanol, n-butanol, and acetonitrile are determined at the atmospheric pressure as a function of the temperature and within the whole composition range. The refractive index of all mixtures (nD) is measured at 298.15†K. The excess molar volumes VE and deviation from additivity rules of viscosities [eta]E and refractive index [Delta][phi]n, of pyrrolidinium octanoate solutions were then deduced from the experimental results as well as apparent molar volumes V[phi]i, partial molar volumes and thermal expansion coefficients [alpha]p. The excess molar volumes VE are negative over the entire mole fraction range for mixture with water, acetonitrile, and methanol indicating strong hydrogen-bonding interaction for the entire mole fraction. In the case of longest carbon chain alcohols (such as ethanol and n-butanol)†+†pyrrolidinium octanoate solutions, the VE variation as a function of the composition describes an S shape. The deviation from additivity rules of viscosities is negative over the entire composition range for the acetonitrile, methanol, ethanol, and butanol, and becomes less negative with increasing temperature. Whereas, [eta]E of the {[Pyrr][C7CO2]†+†water} binary mixtures is positive in the whole mole fraction range and decreases with increasing temperature. the excess Gibbs free energies of activation of viscous flow ([Delta]G*E) for these systems were calculated. The deviation from additivity rules of refractive index [Delta][phi]n are positive over the whole composition range and approach a maximum of 0.25 in PIL mole fraction for all systems. The magnitude of deviation for [Delta][phi]n describes the following order: water†>†methanol†>†acetonitrile†>†ethanol. Results have been discussed in terms of molecular interactions and molecular structures in these binary mixtures.
Resumo:
The densities of five imidazolium-based ionic liquids (ILs) (1-butyl-3-methylimidazolium tetrafluoroborate, [CiC4-Im][BF 4]; 1-butyl-3-methylimidazolium hexafluorophosphate, [CiC 4Im][PF6]; 1-butyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl}imide, [C1C4Im][Tf 2N]; 1-ethyl-3-methylimidazoliumbis{(trifluoromethyl)sulfonyl}-imide, [C1C2Im][Tf2N]; l-ethyl-3-methylimidazolium ethylsulfate, [C1C2Im][EtSO4]) were measured as a function of temperature from (293 to 415) K and over an extended pressure range from (0.1 to 40) MPa using a vibratingtube densimeter. Knowledge of the variation of the density with temperature and pressure allows access to the mechanical coefficients: thermal expansion coefficient and isothermal compressibility. The effects of the anion and of the length of the alkyl chain on the imidazolium ring on the volumetric properties were particularly examined. The mechanical coefficients were compared with those of common organic solvents, water and liquid NaCl. Finally, a prediction model, based on an "ideal" volumetric behavior of the ILs, is proposed to allow calculation of the molar volume of imidazolium-based ionic liquids as a function of temperature. ©2007 American Chemical Society.
Resumo:
Density, rheological properties, and conductivity of a homologous series of ammonium-based ionic liquids N-alkyl-triethylammonium bis{(trifluoromethyl) sulfonyl}imide were studied at atmospheric pressure as a function of alkyl chain length on the cation, as well as of the temperature from (293.15 to 363.15) K. From these investigations, the effect of the cation structure was quantified on each studied properties, which demonstrated, as expected, a decrease of the density and conductivity, a contrario of an increase of the viscosity with the alkyl chain length on the ammonium cation. Furthermore, rheological properties were measured for both pure and water-saturated ionic liquids. The studied ionic liquids were found to be Newtonian and non-Arrhenius. Additionally, the effect of water content in the studied ionic liquids on their viscosity was investigated by adding water until they were saturated at 293.15 K. By comparing the viscosity of pure ionic liquids with the data measured in water-saturated samples, it appears that the presence of water decreases dramatically the viscosity of ionic liquids by up to three times. An analysis of involved transport properties leads us to a classification of the studied ionic liquids in terms of their ionicity using the Walden plot, from which it is evident that they can be classified as "good" ionic liquids. Finally, from measured density data, different volumetric properties, that is, molar volumes and thermal expansion coefficients were determined as a function of temperature and of cationic structure. Based on these volumetric properties, an extension of Jacquemin's group contribution model has been then established and tested for alkylammonium-based ionic liquids within a relatively good uncertainty close to 0.1 %. © 2012 American Chemical Society.
Resumo:
The aim of this work is to determine the out-of-field survival of cells irradiated with either the primary field or scattered radiation in the presence and absence of intercellular communication following delivery of conformal, IMRT and VMAT treatment plans. Single beam, conformal, IMRT and VMAT plans were created to deliver 3 Gy to half the area of a T80 flask containing either DU-145 or AGO-1522 cells allowing intercellular communication between the in-and out-of-field cell populations. The same plans were delivered to a similar custom made phantom used to hold two T25 culture flasks, one flask in-field and one out-of-field to allow comparison of cell survival responses when intercellular communication is physically inhibited. Plans were created for the delivery of 8 Gy to the more radio-resistant DU-145 cells only in the presence and absence of intercellular communication. Cell survival was determined by clonogenic assay. In both cell lines, the out-of-field survival was not statistically different between delivery techniques for either cell line or dose. There was however, a statistically significant difference between survival out-of-field when intercellular communication was intact (single T80 culture flask) or inhibited (multiple T25 culture flasks) to in-field for all plans. No statistically significant difference was observed in-field with or without cellular communication to out-of-field for all plans. These data demonstrate out-of-field effects as important determinants of cell survival following exposure to modulated irradiation fields when cellular communication between differentially irradiated cell populations is present. This data is further evidence that refinement of existing radiobiological models to include indirect cell killing effects is required.
Resumo:
The density of ionic liquids (ILs) as a function of pressure and temperature has been modeled using a group contribution model. This model extends the calculations previously reported (Jacquemin et al. J. Chem. Eng. Data 2008) which used 4000 IL densities at 298.15 K and 600 IL densities as a function of temperature up to 423 K at 0.1 MPa to pressures up to 207 MPa by using described data in the literature and presented in this study. The densities of two different ionic liquids (butyltrimethylammonium bis(trifluoromethylsulfonyl)imide, [N][NTf], and 1-butyl-l-methyl-pyrrolidiniumbis(trifluoromethylsulfonyl)imide, [C mPyrro]-[NTf]) were measured as a function of temperature from (293 to 415) K and over an extended pressure range from (0.1 to 40) MPa using a vibrating-tube densimeter. The model is able to predict the ionic liquid densities of over 5080 experimental data points to within 0.36%. In addition, this methodology allows the calculation of the mechanical coefficients using the calculated density as a function of temperature and pressure with an estimated uncertainty of ± 20%. © 2008 American Chemical Society.
Resumo:
This works follows a publication of our group in J. Chem. Eng. Data2007, 52, 2204–2211 presenting high temperature and pressure density data for five imidazolium-based ionic liquids. At this period, very few ionic liquid density data were available in the literature, especially at high pressure, and the uncertainty of published results was calculated with respect to the literature data available for three of the five ionic liquids studied. Since 2007, the ionic liquid density databank has largely increased. In this work, a comparison of our published data in J. Chem. Eng. Data2007, 52, 2204–2211, with more than 1800 high pressure data coming from the literature up to December 2011 is presented to assess the uncertainty of our published values. The claimed uncertainty is close to 0.31 % for all IL density data sets except in the case of the [C1C2Im][EtSO4], where the uncertainty is up to 1.1 %. Reported data in J. Chem. Eng. Data2007, 52, 2204–2211, for this particular ionic liquid cannot be used as a reference. For this ionic liquid, new density measurements of the same sample batch have been remeasured by using the same experimental technique, and new experimental data presented herein are clearly higher than our previous published results. A 1H NMR analysis of the sample has confirmed hydrolysis of the ethylsulfate anion to ethanol and hydrogenate anion which explains the differences observed between our density data and the literature.
Resumo:
Purpose: The aim of this work was to determine if volumetric modulated arc therapy (VMAT) plans, created for constant dose-rate (cdrVMAT) delivery are a viable alternative to step and shoot five-field intensity modulated radiation therapy (IMRT). Materials and methods: The cdrVMAT plans, inverse planned on a treatment planning system with no solution to account for couch top or rails, were created for delivery on a linear accelerator with no variable dose rate control system. A series of five-field IMRT and cdrVMAT plans were created using dual partial arcs (gantry rotating between 260° and 100°) with 4° control points for ten prostate patients with the average rectal constraint incrementally increased. Pareto fronts were compared for the planning target volume homogeneity and average rectal dose between the two techniques for each patient. Also investigated were tumour control probability and normal tissue complication probability values for each technique. The delivery parameters [monitor units (MU) and time] and delivery accuracy of the IMRT and VMAT plans were also compared. Results: Pareto fronts showed that the dual partial arc plans were superior to the five-field IMRT plans, particularly for the clinically acceptable plans where average rectal doses were less for rotational plans (p = 0·009) with no statistical difference in target homogeneity. The cdrVMAT plans had significantly more MU (p = 0·005) but the average delivery time was significantly less than the IMRT plans by 42%. All clinically acceptable cdrVMAT plans were accurate in their delivery (gamma 99·2 ± 1·1%, 3%3 mm criteria). Conclusions Accurate delivery of dual partial arc cdrVMAT avoiding the couch top and rails has been demonstrated.
Resumo:
PURPOSE: To investigate the effects of using volumetric modulated arc therapy (VMAT) and/or voluntary moderate deep inspiration breath-hold (vmDIBH) in the radiation therapy (RT) of left-sided breast cancer including the regional lymph nodes.
MATERIALS AND METHODS: For 13 patients, four treatment combinations were compared; 3D-conformal RT (i.e., forward IMRT) in free-breathing 3D-CRT(FB), 3D-CRT(vmDIBH), 2 partial arcs VMAT(FB), and VMAT(vmDIBH). Prescribed dose was 42.56 Gy in 16 fractions. For 10 additional patients, 3D-CRT and VMAT in vmDIBH only were also compared.
RESULTS: Dose conformity, PTV coverage, ipsilateral and total lung doses were significantly better for VMAT plans compared to 3D-CRT. Mean heart dose (D(mean,heart)) reduction in 3D-CRT(vmDIBH) was between 0.9 and 8.6 Gy, depending on initial D(mean,heart) (in 3D-CRT(FB) plans). VMAT(vmDIBH) reduced the D(mean,heart) further when D(mean,heart) was still >3.2 Gy in 3D-CRT(vmDIBH). Mean contralateral breast dose was higher for VMAT plans (2.7 Gy) compared to 3DCRT plans (0.7 Gy).
CONCLUSIONS: VMAT and 3D-CRT(vmDIBH) significantly reduced heart dose for patients treated with locoregional RT of left-sided breast cancer. When Dmean,heart exceeded 3.2 Gy in 3D-CRT(vmDIBH) plans, VMAT(vmDIBH) resulted in a cumulative heart dose reduction. VMAT also provided better target coverage and reduced ipsilateral lung dose, at the expense of a small increase in the dose to the contralateral breast.
Resumo:
Background: In a selective group of patients accelerated partial breast irradiation (APBI) might be applied after conservative breast surgery to reduce the amount of irradiated healthy tissue. The role of volumetric modulated arc therapy (VMAT) and voluntary moderately deep inspiration breath-hold (vmDIBH) techniques in further reducing irradiated healthy – especially heart – tissue is investigated.
Material and methods: For 37 partial breast planning target volumes (PTVs), three-dimensional conformal radiotherapy (3D-CRT) (3 – 5 coplanar or non-coplanar 6 and/or 10 MV beams) and VMAT (two partial 6 MV arcs) plans were made on CTs acquired in free-breathing (FB) and/or in vmDIBH. Dose-volume parameters for the PTV, heart, lungs, and breasts were compared.
Results: Better dose conformity was achieved with VMAT compared to 3D-CRT (conformity index 1.24 0.09 vs. 1.49 0.20). Non-PTV ipsilateral breast receiving 50% of the prescribed dose was on average reduced by 28% in VMAT plans compared to 3D-CRT plans. Mean heart dose (MHD) reduced from 2.0 (0.1 – 5.1) Gy in 3D-CRT(FB) to 0.6 (0.1 – 1.6) Gy in VMAT(vmDIBH). VMAT is benefi cial for MHD reduction if MHD with 3D-CRT exceeds 0.5Gy. Cardiac dose reduction as a result of VMAT increases with increasing initial MHD, and adding vmDIBH reduces the cardiac dose further. Mean dose to the ipsilateral lung decreased from 3.7 (0.7 – 8.7) to 1.8 (0.5 – 4.0) Gy with VMAT(vmDIBH) compared to 3D-CRT(FB). VMAT resulted in a slight increase in the contralateral breast dose (DMean ) always remaining 1.9 Gy).
Conclusions: For APBI patients, VMAT improves PTV dose conformity and delivers lower doses to the ipsilateral breast and lung compared to 3D-CRT. This goes at the cost of a slight but acceptable increase of the contralateral breast dose. VMAT reduces cardiac dose if MHD exceeds 0.5 Gy for 3D-CRT. Adding vmDIBH results in a further reduction of heart and ipsilateral lung dose.
Resumo:
Herein, we report the densities and speeds of sound in binary mixtures of three hydrophobic and one hydrophilic ionic liquids: 1-butyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [C4mim][NTf2], 1-butyl-1-methylpyrrolidinium bis[(trifluoromethyl)sulfonyl]imide, [C4mpyr][NTf2], 1-propyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [C3mim][NTf2] and 1-ethyl-3-methylimidazolium thiocyanate, [C2mim][SCN], with water at 298.15 K and 0.1 MPa. The concentration range of water, which encompassed relatively small values well below the saturation point, is often regarded as an impurity for hydrophobic ionic liquids. On the basis of experimental results the molar volume, adiabatic molar compressibility, partial molar volume and apparent molar volume, as well as, partial molar and apparent molar isentropic compressibility properties were then calculated. Interesting results are obtained using the solutions based on the hydrophilic [C2mim][SCN], since these mixtures are characterized by relatively low density and high values of speed of sound. Furthermore, the partial molar volumes and partial molar adiabatic compressibilities of water in solution with [C2mim][SCN] are the lowest among the investigated in mixtures with ionic liquids. However, in the case of the hydrophobic ionic liquid solutions, only small differences are observed for molar adiabatic compressibilities with the change of the cation structure, i.e. for water + [C4mim][NTf2] or + [C4mpyr][NTf2]. A more pronounced difference has been observed for the partial molar compressibility of water in solutions with these two ionic liquids.