110 resultados para visual variables
Visual functioning and quality of life in the subfoveal radiotherapy study (SFRADS): SFRADS report 2
Resumo:
Aims: To determine whether or not self reported visual functioning and quality of life in patients with choroidal neovascularisation caused by age related macular degeneration (AMD) is better in those treated with 12 Gy external beam radiotherapy in comparison with untreated subjects. Methods: A multicentre single masked randomised controlled trial of 12 Gy of external beam radiation therapy (EBRT) delivered as 6x2 Gy fractions to the macula of an affected eye versus observation. Patients with AMD, aged 60 years or over, in three UK hospital units, who had subfoveal CNV and a visual acuity equal to or better than 6/60 (logMAR 1.0). Methods: Data from 199 eligible participants who were randomly assigned to 12 Gy teletherapy or observation were available for analysis. Visual function assessment, ophthalmic examination, and fundus fluorescein angiography were undertaken at baseline and at 3, 6, 12, and 24 months after study entry. To assess patient centred outcomes, subjects were asked to complete the Daily Living Tasks Dependent on Vision (DLTV) and the SF-36 questionnaires at baseline, 6, 12, and 24 months after enrolment to the study. Cross sectional and longitudinal analyses were conducted using arm of study as grouping variable. Regression analysis was employed to adjust for the effect of baseline co-variates on outcome at 12 months and 24 months. Results: Both control and treated subjects had significant losses in visual functioning as seen by a progressive decline in mean scores in the four dimensions of the DLTV. There were no statistically significant differences between treatment and control subjects in any of dimensions of the DLTV at 12 months or 24 months after study entry. Regression analysis confirmed that treatment status had no effect on the change in DLTV dimensional scores. Conclusions: The small benefits noted in clinical measures of vision in treated eyes did not translate into better self reported visual functioning in patients who received treatment when compared with the control arm. These findings have implications for the design of future clinical trials and studies.
Resumo:
Aim: To study the relation between visual impairment and ability to care for oneself or a dependant in older people with age related macular degeneration (AMD). Method: Cross sectional study of older people with visual impairment due to AMD in a specialised retinal service clinic. 199 subjects who underwent visual function assessment (fully corrected distance and near acuity and contrast sensitivity in both eyes), followed by completion of a package of questionnaires dealing with general health status (SF36), visual functioning (Daily Living Tasks Dependent on Vision, DLTV) and ability to care for self or provide care to others. The outcome measure was self reported ability to care for self and others. Three levels of self reported ability to care were identified—inability to care for self (level 1), ability to care for self but not others (level 2), and ability to care for self and others (level 3). Results: People who reported good general health status and visual functioning (that is, had high scores on SF36 and DLTV) were more likely to state that they were able to care for self and others. Similarly people with good vision in the better seeing eye were more likely to report ability to care for self and others. People with a distance visual acuity (DVA) worse than 0.4 logMAR (Snellen 6/15) had less than 50% probability of assigning themselves to care level 3 and those with DVA worse than 1.0 logMAR (Snellen 6/60) had a probability of greater than 50% or for assigning themselves to care level 1. Regression analyses with level of care as the dependent variable and demographic factors, DLTV subscales, and SF36 dimensions as the explanatory variables confirmed that the DLTV subscale 1 was the most important variable in the transition from care level 3 to care level 2. The regression analyses also confirmed that the DLTV subscale 2 was the most important in the transition from care level 3 to care level 1. Conclusions: Ability to care for self and dependants has a strong relation with self reported visual functioning and quality of life and is adversely influenced by visual impairment. The acuity at which the balance of probability shifts in the direction of diminished ability to care for self or others is lower than the level set by social care agencies for provision of support. These findings have implications for those involved with visual rehabilitation and for studies of the cost effectiveness of interventions in AMD.
Resumo:
Recently Ziman et al. [Phys. Rev. A 65, 042105 (2002)] have introduced a concept of a universal quantum homogenizer which is a quantum machine that takes as input a given (system) qubit initially in an arbitrary state rho and a set of N reservoir qubits initially prepared in the state xi. The homogenizer realizes, in the limit sense, the transformation such that at the output each qubit is in an arbitrarily small neighborhood of the state xi irrespective of the initial states of the system and the reservoir qubits. In this paper we generalize the concept of quantum homogenization for qudits, that is, for d-dimensional quantum systems. We prove that the partial-swap operation induces a contractive map with the fixed point which is the original state of the reservoir. We propose an optical realization of the quantum homogenization for Gaussian states. We prove that an incoming state of a photon field is homogenized in an array of beam splitters. Using Simon's criterion, we study entanglement between outgoing beams from beam splitters. We derive an inseparability condition for a pair of output beams as a function of the degree of squeezing in input beams.
Resumo:
We show that two qubits can be entangled by local interactions with an entangled two-mode continuous variable state. This is illustrated by the evolution of two two-level atoms interacting with a two-mode squeezed state. Two modes of the squeezed field are injected respectively into two spatially separate cavities and the atoms are then sent into the cavities to interact resonantly with the cavity field. We find that the atoms may be entangled even by a two-mode squeezed state which has been decohered while penetrating into the cavity.
Resumo:
Primary Objective: To investigate the utility of using a new method of assessment for deficits in selective visual attention (SVA). Methods and Procedures: An independent groups design compared six participants with brain injuries with six participants from a non-brain injured control group. The Sensomotoric Instruments Eye Movement system with remote eye-tracking device (eye camera), and 2 sets of eight stimuli were employed to determine if the camera would be a sensitive discriminator of SVA in these groups. Main Outcomes and Results: The attention profile displayed by the brain injured group showed that they were slower, made more errors, were less accurate, and more indecisive than the control group. Conclusions: The utility of eye movement analysis as an assessment method was established, with implications for rehabilitation requiring further development. Key words: selective visual attention, eye movement analysis, brain injury
Resumo:
We analyze von Neumann-like quantum measurements in terms of simultaneous virtual paths constructed for two noncommuting variables. The approach is applied to measurements of operator functions of conjugate variables and to the joint measurements of such variables. The limits of applicability of the restricted phase space path integral are studied. We demonstrate that, for a simple joint measurement, using entangled meter states allows one to manipulate the order in which the measurements are conducted. The effects of '' weakening '' a measurement by choosing unsharp meter states are also discussed.
Resumo:
The interaction between supernova ejecta and circumstellar matter, arising from previous episodes of mass loss, provides us with a means of constraining the progenitors of supernovae. Radio observations of a number of supernovae show quasi-periodic deviations from a strict power-law decline at late times. Although several possibilities have been put forward to explain these modulations, no single explanation has proven to be entirely satisfactory. Here we suggest that Luminous blue variables undergoing S-Doradus type variations give rise to enhanced phases of mass loss that are imprinted on the immediate environment of the exploding star as a series of density enhancements. The variations in mass loss arise from changes in the ionization balance of Fe, the dominant ion that drives the wind. With this idea, we find that both the recurrence timescale of the variability and the amplitude of the modulations are in line with the observations. Our scenario thus provides a natural, single-star explanation for the observed behaviour that is, in fact, expected on theoretical grounds.
Resumo:
Our understanding of how the visual system processes motion transparency, the phenomenon by which multiple directions of motion are perceived to co-exist in the same spatial region, has grown considerably in the past decade. There is compelling evidence that the process is driven by global-motion mechanisms. Consequently, although transparently moving surfaces are readily segmented over an extended space, the visual system cannot separate two motion signals that co-exist in the same local region. A related issue is whether the visual system can detect transparently moving surfaces simultaneously, or whether the component signals encounter a serial â??bottleneckâ?? during their processing? Our initial results show that, at sufficiently short stimulus durations, observers cannot accurately detect two superimposed directions; yet they have no difficulty in detecting one pattern direction in noise, supporting the serial-bottleneck scenario. However, in a second experiment, the difference in performance between the two tasks disappears when the component patterns are segregated. This discrepancy between the processing of transparent and non-overlapping patterns may be a consequence of suppressed activity of global-motion mechanisms when the transparent surfaces are presented in the same depth plane. To test this explanation, we repeated our initial experiment while separating the motion components in depth. The marked improvement in performance leads us to conclude that transparent motion signals are represented simultaneously.