56 resultados para vision in motion


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intrafraction tumour motion is an issue that is of increased interest in the era of image-guided radiotherapy. It is particularly relevant for non-small cell lung cancer, for which a number of recent developments are in use to aid with motion management in the delivery of radical radiotherapy. The ability to deliver hypofractionated ablative doses, such as in stereotactic radiotherapy, has been aided by improvements in the ability to analyse tumour motion and amend treatment delivery. In addition, accounting for tumour motion can enable dose escalation to occur by reducing the normal tissue being irradiated by virtue of a reduction in target volumes. Motion management for lung tumours incorporates five key components: imaging, breath-hold techniques, abdominal compression, respiratory tracking and respiratory gating. These will be described, together with the relevant benefits and associated complexities. Many studies have described improved dosimetric coverage and reduced normal tissue complication probability rates when using motion management techniques. Despite the widespread uptake of many of these techniques, there is a paucity of literature reporting improved outcome in overall survival and local control for patients whenever motion management techniques are used. This overview will review the extent of lung tumour motion, ways in which motion is detected and summarise the key methods used in motion management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess and improve the accuracy of lay screeners compared with vision professionals in detecting visual impairment in secondary schoolchildren in rural China. METHODS: After brief training, 32 teachers and a team of vision professionals independently measured vision in 1892 children in Xichang. The children also underwent vision measurement by health technicians in a concurrent government screening program. RESULTS: Of 32 teachers, 28 (87.5%) believed that teacher screening was worthwhile. Sensitivity (93.5%) and specificity (91.2%) of teachers detecting uncorrected presenting visual acuity of 20/40 or less were better than for presenting visual acuity (sensitivity, 85.2%; specificity, 84.8%). Failure of teachers to identify children owning but not wearing glasses and teacher bias toward better vision in children wearing glasses explain the worse results for initial vision. Wearing glasses was the student factor most strongly predictive of inaccurate teacher screening (P < .001). The sensitivity and specificity of the government screening program detecting low presenting visual acuity were 86.7% and 28.7%, respectively. CONCLUSIONS: Teacher vision screening after brief training can achieve accurate results in this setting, and there is support among teachers for screening. Screening of uncorrected rather than presenting visual acuity is recommended in settings with a high prevalence of corrected and uncorrected refractive error. Low specificity in the government program renders it ineffective.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aims: To determine whether or not self reported visual functioning and quality of life in patients with choroidal neovascularisation caused by age related macular degeneration (AMD) is better in those treated with 12 Gy external beam radiotherapy in comparison with untreated subjects. Methods: A multicentre single masked randomised controlled trial of 12 Gy of external beam radiation therapy (EBRT) delivered as 6x2 Gy fractions to the macula of an affected eye versus observation. Patients with AMD, aged 60 years or over, in three UK hospital units, who had subfoveal CNV and a visual acuity equal to or better than 6/60 (logMAR 1.0). Methods: Data from 199 eligible participants who were randomly assigned to 12 Gy teletherapy or observation were available for analysis. Visual function assessment, ophthalmic examination, and fundus fluorescein angiography were undertaken at baseline and at 3, 6, 12, and 24 months after study entry. To assess patient centred outcomes, subjects were asked to complete the Daily Living Tasks Dependent on Vision (DLTV) and the SF-36 questionnaires at baseline, 6, 12, and 24 months after enrolment to the study. Cross sectional and longitudinal analyses were conducted using arm of study as grouping variable. Regression analysis was employed to adjust for the effect of baseline co-variates on outcome at 12 months and 24 months. Results: Both control and treated subjects had significant losses in visual functioning as seen by a progressive decline in mean scores in the four dimensions of the DLTV. There were no statistically significant differences between treatment and control subjects in any of dimensions of the DLTV at 12 months or 24 months after study entry. Regression analysis confirmed that treatment status had no effect on the change in DLTV dimensional scores. Conclusions: The small benefits noted in clinical measures of vision in treated eyes did not translate into better self reported visual functioning in patients who received treatment when compared with the control arm. These findings have implications for the design of future clinical trials and studies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Previous work by the authors Walker et al. [2007b. Fluidised bed characterisation using Raman spectroscopy: applications to pharmaceutical processing. Chemical Engineering Science 62, 3832–3838] illustrated that Raman spectroscopy could be used to provide 3-D maps of the concentration and chemical structure of particles in motion in a fluidised bed, within a relatively short (120 s) time window. Moreover, we reported that the technique, as outlined, has the potential to give detailed in-situ information on how the structure and composition of granules/powders within the fluidised bed (dryer or granulator) vary with the position and evolve with time. In this study we extended the original work by shortening the time window of the Raman spectroscopic analysis to 10 s, which has allowed the in-situ real-time characterisation of a fluidised bed granulation process. Here we show an important new use of the technique which allows in-situ measurement of the composition of the material within the fluidised bed in three spatial dimensions and as a function of time. This is achieved by recording Raman spectra using a probe positioned within the fluidised bed on a long-travel x–y–z stage. In these experiments the absolute Raman intensity is used to provide a direct measure of the amount of any given material in the probed volume, i.e. a particle density. Particle density profiles have been calculated over the granulation time and show how the volume of the fluidised bed decreases with an increase mean granule size. The Raman spectroscopy analysis indicated that nucleation/coalescence in this co-melt fluidised hot melt granulation system occurred over a relatively short time frame (t<30 s). The Raman spectroscopic technique demonstrated accurate correlation with independent granulation experiments which provided particle size distribution analysis. The similarity of the data indicates that the Raman spectra accurately represent solids ratios within the bed, and thus the techniques quantitative capabilities for future use in the pharmaceutical industry.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The question of whether homing pigeons use visual landmarks for orientation from distant, familiar sites is an unresolved issue in the field of avian navigation. Where evidence has been found, the question still remains as to whether the landmarks are used independent of the map and compass mechanism for orientation that is so important to birds. Recent research has challenged the extent to which experiments that do not directly manipulate the visual sense can be used as evidence for compass-independent orientation. However, it is proposed that extending a new technique for research on vision in homing to include manipulation of the compasses used by birds might be able to resolve this issue. The effect of the structure of the visual sense of the homing pigeon on its use of visual landmarks is also considered.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We investigated age-related changes in adaptation and sensory reintegration in postural control without vision. In two sessions, participants adapted their posture to sway reference and to reverse sway reference conditions, the former reducing (near eliminating) and the latter enhancing (near doubling) proprioceptive information for posture by means of support-surface rotations in proportion to body sway. Participants stood on a stable platform for 3 min (baseline) followed by 18 min of sway reference or reverse sway reference (adaptation) and finally again on a stable platform for 3 min (reintegration). Results showed that when inaccurate proprioception was introduced, anterior-posterior (AP) sway path length increased in comparable levels in the two age groups. During adaptation, young and older adults reduced postural sway at the same rate. On restoration of the stable platform in the reintegration phase, a sizeable aftereffect of increased AP path length was observed in both groups, which was greater in magnitude and duration for older adults. In line with linear feedback models of postural control, spectral analyses showed that this aftereffect differed between the two platform conditions. In the sway-referenced condition, a switch from low- to high-frequency COP sway marked the transition from reduced to normal proprioceptive information. The opposite switch was observed in the reverse sway referenced condition. Our findings illustrate age-related slowing in participants' postural control adjustments to sudden changes in environmental conditions. Over and above differences in postural control, our results implicate sensory reweighting as a specific mechanism highly sensitive to age-related decline.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

To explore the relation between lesion composition as assessed by fundus photography and fluorescein angiography with clinical measures of vision in eyes of patients with age related macular degeneration (AMD).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In recent years external beam radiotherapy (EBRT) has been proposed as a treatment for the wet form of age-related macular degeneration (AMD) where choroidal neovascularization (CNV) is the hallmark. While the majority of pilot (Phase I) studies have reported encouraging results, a few have found no benefit, i.e. EBRT was not found to result in either improvement or stabilization of visual acuity of the treated eye. The natural history of visual loss in untreated CNV of AMD is highly variable. Loss of vision is influenced mainly by the presenting acuity, and size and composition of the lesion, and to a lesser extent by a variety of other factors. Thus the variable outcome reported by the small Phase I studies of EBRT published to date may simply reflect the variation in baseline factors. We therefore obtained information on 409 patients treated with EBRT from eight independent centres, which included details of visual acuity at baseline and at subsequent follow-up visits. Analysis of the data showed that 22.5% and 14.9% of EBRT-treated eyes developed moderate and severe loss of vision, respectively, during an average follow-up of 13 months. Initial visual acuity, which explained 20.5% of the variation in visual loss, was the most important baseline factor studied. Statistically significant differences in loss of vision were observed between centres, after considering the effects of case mix factors. Comparisons with historical data suggested that while moderate visual loss was similar to that of the natural history of the disease, the likelihood of suffering severe visual loss was halved. However, the benefit in terms of maintained/improved vision in the treated eye was modest.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aim - To report the outcome of a series of patients with stem cell deficiency who underwent allo-limbal transplantation and to describe a technique for this procedure. Methods - Six consecutive patients underwent allo-limbal stem cell transplantation. The primary diagnosis included alkali burn (n = 2), trachoma (n = 1), chronic rosacea blepharitis and keratoconjunctivitis (n = 1), aniridia (n = 1), and Stevens-Johnson syndrome (n = 1). The limbal rim consisted of peripheral cornea and perilimbal sclera, FK-506 was used postoperatively for immunosuppression. Results - The length of follow up ranged from 3 to 24 months (mean follow up 11.8 (SD 9.3) months). The outcome was considered satisfactory in five of six cases. The corneal surface was completely epithelialised within 2 weeks, and there was a substantial improvement in vision and symptoms. One patient had recurrent epithelial defects related to eyelid abnormalities. No side effects associated with systemic immunosuppression were noted. Conclusion - Allo-limbal transplantation, with systemic immunosuppression with FK-506 is useful in reconstruction of the ocular surface with improvement in vision in patients with severe stem cell deficiency.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Leadership and its effectiveness is becoming more prevalent within the nursing profession with anaesthetic nurse specialists showing their ability to lead, inspire and motivate others to work towards a shared vision in the rapidly changing peri-anaesthesia environment. Anaesthetic nurse specialists must therefore be aware of their personal leadership skills and continually develop these within clinical practice. They are also well placed regarding the facilitation of learning.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE. To investigate the methods used in contemporary ophthalmic literature to designate visual acuity (VA). METHODS. Papers in all 2005 editions of five ophthalmic journals were considered. Papers were included if (1) VA, vision, or visual function was mentioned in the abstract and (2) if the study involved age-related macular degeneration, cataract, or refractive surgery. If a paper was selected on the basis of its abstract, the full text of the paper was examined for information on the method of refractive correction during VA testing, type of chart used to measure VA, specifics concerning chart features, testing protocols, and data analysis and means of expressing VA in results. RESULTS. One hundred twenty-eight papers were included. The most common type of charts used were described as logMAR-based. Although most (89.8%) of the studies reported on the method of refractive correction during VA testing, only 58.6% gave the chart design, and less than 12% gave any information whatsoever on chart features or measurement procedures used. CONCLUSIONS. The methods used and the approach to analysis were rarely described in sufficient detail to allow others to replicate the study being reported. Sufficient detail should be given on VA measurement to enable others to duplicate the research. The authors suggest that charts adhering to Bailey-Lovie design principles always be used to measure vision in prospective studies and their use encouraged in clinical settings. The distinction between the terms logMAR, an acuity notation, and Bailey-Lovie or ETDRS as chart types should be adhered to more strictly. Copyright © Association for Research in Vision and Ophthalmology.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background

Diabetic macular oedema (DMO) is a thickening of the central retina, or the macula, and is associated with long-term visual loss in people with diabetic retinopathy (DR). Clinically significant macular oedema (CSMO) is the most severe form of DMO. Almost 30 years ago, the Early Treatment Diabetic Retinopathy Study (ETDRS) found that CSMO, diagnosed by means of stereoscopic fundus photography, leads to moderate visual loss in one of four people within three years. It also showed that grid or focal laser photocoagulation to the macula halves this risk. Recently, intravitreal injection of antiangiogenic drugs has also been used to try to improve vision in people with macular oedema due to DR.Optical coherence tomography (OCT) is based on optical reflectivity and is able to image retinal thickness and structure producing cross-sectional and three-dimensional images of the central retina. It is widely used because it provides objective and quantitative assessment of macular oedema, unlike the subjectivity of fundus biomicroscopic assessment which is routinely used by ophthalmologists instead of photography. Optical coherence tomography is also used for quantitative follow-up of the effects of treatment of CSMO.

Objectives

To determine the diagnostic accuracy of OCT for detecting DMO and CSMO, defined according to ETDRS in 1985, in patients referred to ophthalmologists after DR is detected. In the update of this review we also aimed to assess whether OCT might be considered the new reference standard for detecting DMO.

Search methods

We searched the Cochrane Database of Systematic Reviews (CDSR), the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA) and the NHS Economic Evaluation Database (NHSEED) (The Cochrane Library 2013, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2013), EMBASE (January 1950 to June 2013), Web of Science Conference Proceedings Citation Index - Science (CPCI-S) (January 1990 to June 2013), BIOSIS Previews (January 1969 to June 2013), MEDION and the Aggressive Research Intelligence Facility database (ARIF). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 25 June 2013. We checked bibliographies of relevant studies for additional references.

Selection Criteria

We selected studies that assessed the diagnostic accuracy of any OCT model for detecting DMO or CSMO in patients with DR who were referred to eye clinics. Diabetic macular oedema and CSMO were diagnosed by means of fundus biomicroscopy by ophthalmologists or stereophotography by ophthalmologists or other trained personnel.

Data collection and analysis

Three authors independently extracted data on study characteristics and measures of accuracy. We assessed data using random-effects hierarchical sROC meta-analysis models.

Main results

We included 10 studies (830 participants, 1387 eyes), published between 1998 and 2012. Prevalence of CSMO was 19% to 65% (median 50%) in nine studies with CSMO as the target condition. Study quality was often unclear or at high risk of bias for QUADAS 2 items, specifically regarding study population selection and the exclusion of participants with poor quality images. Applicablity was unclear in all studies since professionals referring patients and results of prior testing were not reported. There was a specific 'unit of analysis' issue because both eyes of the majority of participants were included in the analyses as if they were independent.In nine studies providing data on CSMO (759 participants, 1303 eyes), pooled sensitivity was 0.78 (95% confidence interval (CI) 0.72 to 0.83) and specificity was 0.86 (95% CI 0.76 to 0.93). The median central retinal thickness cut-off we selected for data extraction was 250 µm (range 230 µm to 300 µm). Central CSMO was the target condition in all but two studies and thus our results cannot be applied to non-central CSMO.Data from three studies reporting accuracy for detection of DMO (180 participants, 343 eyes) were not pooled. Sensitivities and specificities were about 0.80 in two studies and were both 1.00 in the third study.Since this review was conceived, the role of OCT has changed and has become a key ingredient of decision-making at all levels of ophthalmic care in this field. Moreover, disagreements between OCT and fundus examination are informative, especially false positives which are referred to as subclinical DMO and are at higher risk of developing clinical CSMO.

Authors' conclusions

Using retinal thickness thresholds lower than 300 µm and ophthalmologist's fundus assessment as reference standard, central retinal thickness measured with OCT was not sufficiently accurate to diagnose the central type of CSMO in patients with DR referred to retina clinics. However, at least OCT false positives are generally cases of subclinical DMO that cannot be detected clinically but still suffer from increased risk of disease progression. Therefore, the increasing availability of OCT devices, together with their precision and the ability to inform on retinal layer structure, now make OCT widely recognised as the new reference standard for assessment of DMO, even in some screening settings. Thus, this review will not be updated further.