137 resultados para units samples


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports an experimental study in which samples of soft kaolin clay (100 mm in diameter and 200 mm in height) were reinforced with vertical columns of sand and tested under triaxial conditions. Samples were reinforced with either a single column of sand of 32 mm diameter or three columns of sand, each of 20 mm diameter. The replacement method was used to form the columns. The columns were installed in the clay to depths of 120 and 200 mm. Tests were also carried out on samples that were not reinforced with sand columns. The samples were compressed under both drained and undrained conditions. It was found that the undrained shear strength of samples containing full-depth columns was greatly improved compared with that of the unreinforced samples. In the fully drained tests, the sample installed with a single column of 32 mm diameter exhibited better performance than the sample with three columns of 20 mm diameter, although the area replacement ratio in the case of the three 20 mm diameter columns was higher than that of the single 32 mm diameter column. However, the undrained strength of the composite material was not particularly affected by the number of columns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcription from morbillivirus genomes commences at a single promoter in the 3' non-coding terminus, with the six genes being transcribed sequentially. The 3' and 5' untranslated regions (UTRs) of the genes (mRNA sense), together with the intergenic trinucleotide spacer, comprise the non-coding sequences (NCS) of the virus and contain the conserved gene end and gene start signals, respectively. Bicistronic minigenomes containing transcription units (TUs) encoding autofluorescent reporter proteins separated by measles virus (MV) NCS were used to give a direct estimation of gene expression in single, living cells by assessing the relative amounts of each fluorescent protein in each cell. Initially, five minigenomes containing each of the MV NCS were generated. Assays were developed to determine the amount of each fluorescent protein in cells at both cell population and single-cell levels. This revealed significant variations in gene expression between cells expressing the same NCS-containing minigenome. The minigenome containing the M/F NCS produced significantly lower amounts of fluorescent protein from the second TU (TU2), compared with the other minigenomes. A minigenome with a truncated F 5' UTR had increased expression from TU2. This UTR is 524 nt longer than the other MV 5' UTRs. Insertions into the 5' UTR of the enhanced green fluorescent protein gene in the minigenome containing the N/P NCS showed that specific sequences, rather than just the additional length of F 5' UTR, govern this decreased expression from TU2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the detection of several synthetic glucocorticoids in kidney, muscle and hair samples of cattle after a single intramuscular injection is described. After a dichloromethane wash of the hair samples, analytes were released from the hair matrix by enzymatic digestion. Muscle samples were also digested enzymatically using proteinase, while kidney samples were deconjugated by Helix pomatia juice. These preliminary steps were followed by a methanol extraction and a solid phase extraction (SPE) clean up step for all matrices. Chromatographic separation was achieved on a Hypersil Hypercarb column and MS/MS data were obtained in the multiple reaction monitoring mode using negative electrospray ionization. The developed protocols were evaluated by assessing residue concentrations in muscle, kidney and hair samples of thirteen calves, treated with a particular intramuscular injection of glucocorticoid. The lowest residue levels were found in muscle samples (approximately 5% of the residue levels in kidney), while high residue levels were obtained in hair samples. Hair is an interesting matrix since the sampling is non-invasive and the drugs may stay incorporated for a longer period of time. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compounds possessing antioxidant activity play a crucial role in delaying or preventing lipid oxidation in foods and beverages during processing and storage. Such reactions lead to loss of product quality, especially as a consequence of off-flavor formation. The aim of this study was to determine the antioxidant activity of kilned (standard) and roasted (speciality) malts in relation to phenolic compounds, sugars, amino acids, and color [assessed as European Brewing Convention units (degrees EBC) and absorbance at 420 nm]. The concentrations of sugars and amino acids decreased with the intensity of the applied heat treatment, and this was attributed to the extent of the Maillard reaction, as well as sugar caramelization, in the highly roasted malts. Proline, followed by glutamine, was the most abundant free amino/imino acid in the malt samples, except those that were highly roasted, and maltose was the most abundant sugar in all malts. Levels of total phenolic compounds decreased with heat treatment. Catechin and ferulic acid were the most abundant phenolic compounds in the majority of the malts, and amounts were highest in the kilned samples. In highly roasted malts, degradation products of ferulic acid were identified. Antioxidant activity increased with the intensity of heating, in parallel with color formation, and was significantly higher for roasted malts compared to kilned malts. In kilned malts, phenolic compounds were the main identified contributors to antioxidant activity, with Maillard reaction products also playing a role. In roasted malts, Maillard reaction products were responsible for the majority of the antioxidant activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aqueous extracts were prepared from five barley crystal malts (color range 15-440 degrees EBC, European Brewing Convention units). Antioxidant activity was determined by using the 2,2'-azinobis(3-ethylbenothiazoline-6-sulfonic acid) (ABTS(.+)) radical cation scavenging method. Antioxidant activity increased with increasing color value although the rate of increase decreased with increasing color value. Color was measured in CIELAB space. Extracts of the 15, 23, and 72 degrees EBC malts followed the same dilution pathway as did the 148 degrees EBC sample at higher dilution levels, indicating that they could each be used to give the same color by appropriate dilution. The 440 degrees EBC sample followed a different dilution pathway, indicating that different compounds were responsible for color in this extract. Fifteen selected volatile compounds were monitored using gas chromatography/mass spectrometry (GC/MS). Levels of methylpropanal, 2-methylbutanal, and 3-methylbutanal were highest for the 72 degrees EBC sample. When odor threshold values of the selected compounds were taken into account, 3-methylbutanal was the most important contributor to flavor., Relationships between levels of the lipid oxidation products, hexanal and (E)-2-nonenal, and antioxidant activity were complex, and increasing antioxidant activity for samples in the range of 15-148 degrees EBC did-not result in reduced levels of these lipid-derived compounds. When different colored malt extracts were diluted to give the same a* and b* values, calculated antioxidant activity and amounts of 3-methylbutanal, hexanal, and (E)-2-nonenal decreased with increasing degrees EBC value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quartz crystal impedance analysis has been developed as a technique to assess whether room-temperature ionic liquids are Newtonian fluids and as a small-volume method for determining the values of their viscosity-density product, rho eta. Changes in the impedance spectrum of a 5-MHz fundamental frequency quartz crystal induced by a water-miscible room-temperature ionic liquid, 1-butyl-3-methylimidazolium. trifluoromethylsulfonate ([C(4)mim][OTf]), were measured. From coupled frequency shift and bandwidth changes as the concentration was varied from 0 to 100% ionic liquid, it was determined that this liquid provided a Newtonian response. A second water-immiscible ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide [C(4)mim][NTf2], with concentration varied using methanol, was tested and also found to provide a Newtonian response. In both cases, the values of the square root of the viscosity-density product deduced from the small-volume quartz crystal technique were consistent with those measured using a viscometer and density meter. The third harmonic of the crystal was found to provide the closest agreement between the two measurement methods; the pure ionic liquids had the largest difference of similar to 10%. In addition, 18 pure ionic liquids were tested, and for 11 of these, good-quality frequency shift and bandwidth data were obtained; these 12 all had a Newtonian response. The frequency shift of the third harmonic was found to vary linearly with square root of viscosity-density product of the pure ionic liquids up to a value of root(rho eta) approximate to 18 kg m(-2) s(-1/2), but with a slope 10% smaller than that predicted by the Kanazawa and Gordon equation. It is envisaged that the quartz crystal technique could be used in a high-throughput microfluidic system for characterizing ionic liquids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The five room temperature ionic liquids: 1-alkyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([CnMIM][N(Tf)(2)], n = 2, 4, 8, 10) and n-hexyltriethylammonium bis(trifluoromethylsulfonyl)imide ([N-6222][N(Tf)(2)]) were investigated as solvents in which to study the electrochemical oxidation of N,N,N',N'-tetramethyl-para-phenylenediamine (TMPD) and N,N,N',N'-tetrabutyl-paraphenylenediamine (TBPD), using 20 mul micro-samples under vacuum conditions. The effect of dissolved atmospheric gases on the accessible electrochemical window was probed and determined to be less significant than seen previously for ionic liquids containing alternative anions. Chronoamperometric transients recorded at a microdisk electrode were analysed via a process of non-linear curve fitting to yield values for the diffusion coefficients of the electroactive species without requiring a knowledge of their initial concentration. Comparison of experimental and simulated cyclic voltammetry was then employed to corroborate these results and allow diffusion coefficients for the electrogenerated species to be estimated. The diffusion coefficients obtained for the neutral compounds in the five ionic liquids via this analysis were, in units of 10(-11) m(2) s(-1), 2.62, 1.87, 1.12, 1.13 and 0.70 for TMPD. and 1.23, 0.80, 0.40, 0.52 and 0.24 for TBPD (listed using the same order for the ionic liquids as stated above). The most significant consequence of changing the cationic component of the ionic liquid was found to be its effect on the solvent viscosity; the diffusion coefficient of each species was found to be approximately inversely proportional to viscosity across the series of ionic liquids, in accordance with Walden's rule. (C) 2003 Elsevier B.V. All rights reserved.