75 resultados para the scanning reference electrode technique


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The voltammetry and kinetics of the Ag vertical bar Ag+ system (commonly used as a reference electrode material in both protic/aprotic and RTIL solvents) was studied in the room-temperature ionic liquid N-butyl-N-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide, [C(4)mpyrr][NTf2] on a 10 mu m diameter Pt electrode. For the three silver salts investigated (AgOTf, AgNTf2, and AgNO3, where OTf- = trifluoromethanesulfonate, NTf2- = bis(trifluoromethylsulfonyl)imide, and NO3- = nitrate), the voltammetry gave rise to a redox couple characteristic of a

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The European Cystic Fibrosis Society Clinical Trial Network (ECFS-CTN) has established a Standardization Committee to undertake a rigorous evaluation of promising outcome measures with regard to use in multicentre clinical trials in cystic fibrosis (CF). The aim of this article is to present a review of literature on clinimetric properties of the infant raised-volume rapid thoracic compression (RVRTC) technique in the context of CF, to summarise the consensus amongst the group on feasibility and answer key questions regarding the promotion of this technique to surrogate endpoint status.

METHODS: A literature search (from 1985 onwards) identified 20 papers that met inclusion criteria of RVRTC use in infants with CF. Data were extracted and tabulated regarding repeatability, validity, correlation with other outcome measures, responsiveness and reference values. A working group discussed the tables and answered 4 key questions.

RESULTS: Overall, RVRTC in particular forced expiratory volume in 0.5s, showed good clinimetric properties despite presence of individual variability. Few studies showed a relationship between RVRTC and inflammation and infection, and to date, data remains limited regarding the responsiveness of RVRTC after an intervention. Concerns were raised regarding feasibility in multi-centre studies and availability of reference values.

CONCLUSION: The ECFS-CTN Working Group considers that RVRTC cannot be used as a primary outcome in clinical trials in infants with CF before universal standardization of this measurement is achieved and implementation of inter-institutional networking is in place. We advise its use currently in phase I/II trials and as a secondary endpoint in phase III studies. We emphasise the need for (1) more short-term variability and longitudinal 'natural history' studies, and (2) robust reference values for commercially available devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When operated with a metallic tip and sample the scanning tunnelling microscope constitutes a nanoscale, plasmonic light source yielding broadband emission up to a photon energy determined by the applied bias. The emission is due to tunnelling electron excitation and subsequent radiative decay of localized plasmon modes, which can be on the lateral scale of a single metal grain (similar to 25 nm) or less. For a Au-tip/Au-polycrystalline sample under ambient conditions it is found that the intensity and spectral content of the emitted light are not dependent on the lateral grain dimension, but are predominantly determined by the tip geometry. However, the intensity increases strongly with increasing film thickness (grain depth) up to 20-25 nm or approximately the skin depth of the Au film. Photon maps can show less emissive grains and two classes of this occurrence are distinguished. The first is geometrical in origin - a double-tip structure in this case - while the second is due to a contamination-induced lowering of the local work function that causes the tunnel gap to increase. It is suggested that differences in work-function lowering between grains presenting different crystalline facets, combined with an exponential decay in emitted light intensity with tip - sample distance, leads to grain contrast. These results are relevant to tip-enhanced Raman scattering and the fabrication of micro/nano-scale planar, light-emitting tunnel devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Freestanding polyparaphenylene films were obtained on polymerization of benzene at potential of 1.2 V versus Al wire on substrates like platinum/transparent conducting glass as an anode. The electrolyte used was chloroaluminate room-temperature melt, which was prepared by intimate mixing of a 1:2 ratio of cetyl pyridinium chloride and anhydrous aluminum chloride to yield a viscous liquid. This liquid was miscible in all proportions with benzene and other aromatic hydrocarbons in all proportions at room temperature. The polyparaphenylene films deposited on platinum anode exhibited a prominent cyclic voltammetric peak at 0.7 V versus Al wire as reference electrode in chloroaluminate medium. The impedance spectra gave low charge transfer resistance. The diffused reflectance electronic spectra of the film gave the peaks at 386 nm and 886 nm. The PPP films showed electronic conductivity around 3–4 × 104 S/cm by four probe method under nitrogen atmosphere. The polymer was also characterized by IR spectra, thermal studies, and SEM studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bluish-black shining free standing polypyrrole film (PPy) of electronic conductivity 130 S cm-1 has been prepared by electrochemical oxidative polymerization of pyrrole on Pt/transparent glass conducting electrode resistance 15 O cm-1, using a room temperature melt as an electrolyte, composed of 1:3 stoichiometric ratio of cetyl pyridinium chloride and anhydrous aluminum chloride at 0.58 V versus Al wire as a reference electrode. The film possessed a charge transfer resistance of 132 O, and showed two absorption peaks at 457 and 1264 nm in the UV-vis–NIR diffused reflectance spectra. The morphology of the film was hexagonal. The potential step technique suggested a layered structure. This thin film can easily be peeled off from the electrode surface after three cycles and can be used for various applications like dissipation of electrostatic charge, battery electrode materials, solid electrolytic capacitor, electrochromic windows and displays, microactuators etc. It was also characterized by IR, thermal and SEM studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To determine the sensitivity and specificity of the non-invasive imaging technique, fundus autofluorescence (AF), in the diagnosis of cystoid macular oedema (CMO), using fluorescein angiography as the reference standard. Design: Retrospective, consecutive, observational case series. Methods: Ninety-six consecutive patients with CMO suspected clinically were selected from the AF database of the Retina Unit, Ophthalmology Department, Grampian University Hospitals-NHS Trust, between August 2004 and June 2006. Only patients in whom CMO was secondary to (1) cataract extraction, (2) inherited retinopathies, (3) inflammatory eye disease or (4) idiopathic cases were included in this study. Only patients in whom AF images had been performed within 2 weeks of FFA and, when obtained following FFA, there was a minimum gap of 4 days ("washing out" period), were considered eligible for this study. A total of 34 eyes from 34 patients were eligible and were included in this study. FFA was used as the reference test to confirm the presence of CMO, and, based on fluorescein angiography (FFA), CMO was graded as either mild or florid. AF images were examined in a masked fashion for the presence or absence of CMO. The sensitivity and specificity of AF in detecting CMO were then calculated. Results: CMO was seen on AF imaging as round or oval areas at the fovea with an AF signal similar to that of background levels. At this site (fovea), the AF signal is usually reduced compared with background, due to the blockage caused by luteal pigment. The diagnosis of CMO based on AF imaging had 81% sensitivity and 69% specificity when compared with the reference standard FFA. Based on the FFA, there were 12 cases of florid CMO and eight of mild CMO. Of the former, CMO was detected with AF imaging in 100% (12/12 eyes), and of the latter, in 50% (4/8 eyes). Conclusions: AF imaging can be used as a rapid, non-invasive technique in the diagnosis of CMO.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In situ FTIR spectroscopic and electrochemical data and ex situ (emersion) electron diffraction (LEED) and RHEED) and Auger spectroscopic data are presented on the structure and reactivity, with respect to the electro-oxidation of CO, of the Ru(0001) single-crystal surface in perchloric acid solution. In both the absence and the presence of adsorbed CO, the Ru(0001) electrode shows the potential-dependent formation of well-defined and ordered oxygen-containing adlayers. At low potentials (e.g., from -80 to +200 mV vs Ag/AgCl), a (2 × 2)-O phase, which is unreactive toward CO oxidation, is formed, in agreement with UHV studies. Increasing the potential results in the formation of (3 × 1) and (1 × 1) phases at 410 and 1100 mV, respectively, with a concomitant increase in the reactivity of the surface toward CO oxidation. Both linear (CO ) and three-fold-hollow (CO ) binding CO adsorbates (bands at 2000-2040 and 1770-1800 cm , respectively) were observed on the Ru(0001) electrode. The in situ FTIR data show that the adsorbed CO species remain in compact islands as CO oxidation proceeds, suggesting that the oxidation occurs at the boundaries between the CO and O domains. At low CO coverages, reversible relaxation (at lower potentials) and compression (at higher potentials) of the CO adlayer were observed and rationalized in terms of the reduction and formation of surface O adlayers. The data obtained from the Ru(0001) electrode are in marked contrast to those observed on polycrystalline Ru, where only linear CO is observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a simple and facile methodology for constructing Pt (6.3 mm x 50 mu m) and Cu (6.3 mm x 30 mu m) annular microband electrodes for use in room temperature ionic liquids (RTILs) and propose their use for amperometric gas sensing. The suitability of microband electrodes for use in electrochemical analysis was examined in experiments on two systems. The first system studied to validate the electrochemical responses of the annular microband electrode was decamethylferrocene (DmFc), as a stable internal reference probe commonly used in ionic liquids, in [Pmim][NTf2], where the diffusion coefficients of DmFc and DmFc(+) and the standard electron rate constant for the DmFc/DmFc(+) couple were determined through fitting chronoamperometric and cyclic voltammetric responses with relevant simulations. These values are independently compared with those collected from a commercially available Pt microdisc electrode with excellent agreement. The second system focuses on O-2 reduction in [Pmim][NTf2], which is used as a model for gas sensing. The diffusion coefficients of O-2 and O-2(-) and the electron transfer rate constant were again obtained using chronoamperometry and cyclic voltammetry, along with simulations. Results determined from the microbands are again consistent to those evaluated from the Pt microdisc electrode when compared these results from home-made microband and commercially available microdisc electrodes. These observations indicate that the fabricated annular microband electrodes are suitable for quantitative measurements. Further the successful use of the Cu electrodes in the O-2 system suggests a cheap disposable sensor for gas detection. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports image analysis methods that have been developed to study the microstructural changes of non-wovens made by the hydroentanglement process. The validity of the image processing techniques has been ascertained by applying them to test images with known properties. The parameters in preprocessing of the scanning electron microscope (SEM) images used in image processing have been tested and optimized. The fibre orientation distribution is estimated using fast Fourier transform (FFT) and Hough transform (HT) methods. The results obtained using these two methods are in good agreement. The HT method is more demanding in computational time compared with the Fourier transform (FT) method. However, the advantage of the HT method is that the actual orientation of the lines can be concluded directly from the result of the transform without the need for any further computation. The distribution of the length of the straight fibre segments of the fabrics is evaluated by the HT method. The effect of curl of the fibres on the result of this evaluation is shown.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Currently there is no reliable objective method to quantify the setting properties of acrylic bone cements within an operating theatre environment. Ultrasonic technology can be used to determine the acoustic properties of the polymerising bone cement, which are linked to material properties and provide indications of the physical and chemical changes occurring within the cement. The focus of this study was the critical evaluation of pulse-echo ultrasonic test method in determining the setting and mechanical properties of three different acrylic bone cement when prepared under atmospheric and vacuum mixing conditions. Results indicated that the ultrasonic pulse-echo technique provided a highly reproducible and accurate method of monitoring the polymerisation reaction and indicating the principal setting parameters when compared to ISO 5833 standard, irrespective of the acrylic bone cement or mixing method used. However, applying the same test method to predict the final mechanical properties of acrylic bone cement did not prove a wholly accurate approach. Inhomogeneities within the cement microstructure and specimen geometry were found to have a significant influence on mechanical property predictions. Consideration of all the results suggests that the non-invasive and non-destructive pulse-echo ultrasonic test method is an effective and reliable method for following the full polymerisation reaction of acrylic bone cement in real-time and then determining the setting properties within a surgical theatre environment. However the application of similar technology for predicting the final mechanical properties of acrylic bone cement on a consistent basis may prove difficult.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Increasing tungsten (W) use for industrial and military applications has resulted in greater W discharge into natural waters, soils and sediments. Risk modeling of W transport and fate in the environment relies on measurement of the release/mobilization flux of W in the bulk media and the interfaces between matrix compartments. Diffusive gradients in thin-films (DGT) is a promising passive sampling technique to acquire such information. DGT devices equipped with the newly developed high-resolution binding gels (precipitated zirconia, PZ, or ferrihydrite, PF, gels) or classic/conventional ferrihydrite slurry gel were comprehensively assessed for measuring W in waters. FerrihydriteDGT can measure W at various ionic strengths (0.001–0.5 mol L−1 NaNO3) and pH (4–8), while PZDGT can operate across slightly wider environmental conditions. The three DGT configurations gave comparable results for soil W measurement, showing that typically W resupply is relatively poorly sustained. 1D and 2D high-resolution W profiling across sediment—water and hotspot—bulk media interfaces from Lake Taihu were obtained using PZDGT coupled with laser ablation ICP–MS measurement, and the apparent diffusion fluxes across the interfaces were calculated using a numerical model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

1. Isolated sheep urethral cells were studied using the perforated patch clamp technique (T = 37 degrees C). Depolarizing steps ranging from -40 to -10 mV evoked an inward current that peaked within 10 ms and a slower inward current. Stepping back to the holding potential of -80 mV evoked large inward tail currents. All three currents were abolished by nifedipine (1 microM). Substitution of external Ca2+ with Ba2+ resulted in potentiation of the fast inward current and blockade of the slow current and tails. 2. Changing the chloride equilibrium potential (ECl) from 0 to +27 mV shifted the reversal potential of the tail currents from 1 +/- 1 to 27 +/- 1 mV (number of cells, n = 5). Chloride channel blockers, niflumic acid (10 microM) and anthracene-9-carboxylic acid (9AC, 1 mM), reduced the slow current and tails suggesting that these were Ca(2+)-activated Cl- currents, ICl(Ca). 4. Caffeine (10 mM) induced currents that reversed at ECl and were blocked by niflumic acid (10 microM). 5. In current clamp mode, some cells developed spontaneous transient depolarizations (STDs) and action potentials. Short exposure to nifedipine blocked the action potentials and unmasked STDs. In contrast, 9AC and niflumic acid reduced the amplitude of the STDs and blocked the action potentials. 6. In conclusion, these cells have both L-type ICa and ICl(Ca). The former appears to be responsible for the upstroke of the action potential, while the latter may act as a pacemaker current.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electron beam trajectory simulations have been performed to design a new electron beam ion trap. The design of the magnet and electrode structures was optimized based on the results of the simulations. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a practical scheme for performing ab initio supercell calculations of charged slabs at constant electron chemical potential mu, rather than at constant number of electrons N-e. To this end, we define the chemical potential relative to a plane (or "reference electrode") at a finite distance from the slab (the distance should reflect the particular geometry of the situation being modeled). To avoid a net charge in the supercell, and thus make possible a standard supercell calculation, we restore the electroneutrality of the periodically repeated unit by means of a compensating charge, whose contribution to the total energy and potential is subtracted afterwards. The "constant mu" mode enables one to perform supercell calculation on slabs, where the slab is kept at a fixed potential relative to the reference electrode. We expect this to be useful in modeling many experimental situations, especially in electro-chemistry. (C) 2001 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Australasian anuran amphibian genus Litoria, contains many phenotypically-diverse species as a result of radial evolution of an ancestral species into different biotopes much in the manner of the indigenous marsupial mammals. In common with members of the Central/South American genus Phyllomedusa, their specialized skin granular glands are factories for the production of a plethora of biologically-active peptides. Here we report a more detailed study of those present in the defensive skin secretion of the Australasian giant white-lipped tree frog, Litoria infrafrenata, and, for the first time, we have identified three novel frenatins by deduction of primary structures from cDNAs that were cloned from a library constructed from lyophilized skin secretion using a recently-developed technique. All open-reading frames consisted of a putative signal peptide and an acidic pro-region followed by a single copy of a frenatin peptide. Processed peptides corresponding in molecular mass to the deduced molecular masses of frenatins (named 1.1, 3, 3.1 and 4.1) were identified in the same secretion sample using HPLC and mass spectroscopy. The application of this technique thus permits parallel peptidomic and transcriptomic analyzes on the same lyophilized skin secretion sample circumventing sacrifice of specimens from endangered herpetofauna.