36 resultados para testing-effect
Resumo:
A controlled-atmosphere chamber, combined with a CCTV system, is used to monitor continuously the change in shape of water droplets on the self-cleaning commercial glass, Activ, and a sol-gel TiO2 substrate during their irradiation with either UVA or UVC light. This system allows the photoinduced superhydrophilic effect (PSH) exhibited by these materials to be studied in real time under a variety of different conditions. UVA was less effective than UVC in terms of PSH for both titania-coated glasses, and plain glass was unaffected by either form of UV irradiation and so showed no PSH activity. With UVA, ozone increased significantly the rate of PSH for both substrates, but had no effect on the wettability of plain glass. For both titania substrates and plain glass, no PSH activity was observed under an O-2-free atmosphere. A more detailed study of the PSH effect exhibited by Activ revealed that doping the water droplet with either an electron acceptor (Na2S2O8), electron donor (Na2S2O4), or simple electrolyte (KCl) in the absence of oxygen did not promote PSH. However, when Activ was UV irradiated, while immersed in a deoxygenated KCl solution, prior to testing for PSH activity, only a small change in contact angle was observed, whereas under the same conditions, but using a deoxygenated persulfate-containing immersion solution, it was rendered superhydrophilic. The correlation between organic contaminant removal and surface wetting was also investigated by using thick sol-gel films coated with stearic acid; the destruction of SA was monitored by FTIR and sudden wetting of the surface was seen to coincide with the substantial removal of the organic layer. The results of this work are discussed in the context of the current debate on the underlying cause of PSH.
Resumo:
Fibre distribution and orientation in a series of round panel specimens of ultra high performance fibre reinforced concrete (UHPFRC) was investigated using electrical resistivity measurements and confirmed by X-ray CT imaging. By pouring specimens in different ways, the orientation of steel fibres was influenced and the sensitivity of the electrical resistivity technique was investigated. The round panels were tested in flexure and the results are discussed in relation to the observed orientation of fibres in the panels. It was found that the fibres tended to align perpendicular to the direction of flow. As a result, panels poured from the centre were significantly stronger than panels poured by other methods because the alignment of fibres led to more fibres bridging the radial cracks formed during mechanical testing.
Resumo:
In two experiments, we tested some of the central claims of the empathizing-systemizing (E-S) theory. Experiment 1 showed that the systemizing quotient (SQ) was unrelated to performance on a mathematics test, although it was correlated with statistics-related attitudes, self-efficacy, and anxiety. In Experiment 2, systemizing skills, and gender differences in these skills, were more strongly related to spatial thinking styles than to SQ. In fact, when we partialled the effect of spatial thinking styles, SQ was no longer related to systemizing skills. Additionally, there was no relationship between the Autism Spectrum Quotient (AQ) and the SQ, or skills and interest in mathematics and mechanical reasoning. We discuss the implications of our findings for the E-S theory, and for understanding the autistic cognitive profile.
Resumo:
A full-scale 34 m composite wind turbine blade was tested to failure under flap-wise loading. Local displacement measurement equipment was developed and displacements were recorded throughout the loading history.
Ovalization of the load carrying box girder was measured in the full-scale test and simulated in non-linear FE-calculations. The nonlinear Brazier effect is characterized by a crushing pressure which causes the ovalization. To capture this effect, non-linear FE-analyses at different scales were employed. A global non-linear FE-model of the entire blade was prepared and the boundaries to a more detailed sub-model were extracted. The FE-model was calibrated based on full-scale test measurements.
Local displacement measurements helped identify the location of failure initiation which lead to catastrophic failure. Comparisons between measurements and FE-simulations showed that delamination of the outer skin was the initial failure mechanism followed by delamnination buckling which then led to collapse.
Resumo:
NiTi wires of 0.5 mm diameter were laser welded using a CW 100-W fiber laser in an argon shielding environment with or without postweld heat-treatment (PWHT). The microstructure and the phases present were studied by scanning-electron microscopy (SEM), transmission-electron microscopy (TEM), and X-ray diffractometry (XRD). The phase transformation behavior and the cyclic stress–strain behavior of the NiTi weldments were studied using differential scanning calorimetry (DSC) and cyclic tensile testing. TEM and XRD analyses reveal the presence of Ni4Ti3 particles after PWHT at or above 623 K (350 °C). In the cyclic tensile test, PWHT at 623 K (350 °C) improves the cyclic deformation behavior of the weldment by reducing the accumulated residual strain, whereas PWHT at 723 K (450 °C) provides no benefit to the cyclic deformation behavior. Welding also reduces the tensile strength and fracture elongation of NiTi wires, but the deterioration could be alleviated by PWHT.
Resumo:
Lightning strike is one of the challenges that the aerospace industry is facing in an effort to increase the percentage of composite materials used in aircraft structures. Lightning strike damage is due to high orthotropic electric resistivity of the composite panels, which leads to high thermal loads that cause decomposition of the epoxy and delimitations of the laminates. Yet, experimental testing of lightning strike on aircraft panels is expensive due to the large number of design parameters that can control the inflicted damage. A coupled thermal-electrical finite element analysis is used to investigate the design variables space that can affect lightning strike damage on epoxy/graphite composite panels. The contribution of this study is modeling the composite panels’ material properties as temperature dependent, which was excluded by other researchers. A number of practical solutions to minimize the damage effect are proposed. Two set of experimental results are used to verify the numerical ones. One experimental set for plain composite panel, and second one for composite panels with joints
Resumo:
In this study, the stress-corrosion cracking (SCC) behaviour of laser-welded NiTi wires before and after post-weld heat-treatment (PWHT) was investigated. The samples were subjected to slow strain rate testing (SSRT) under tensile loading in Hanks’ solution at 37.5 °C (or 310.5 K) at a constant anodic potential (200 mVSCE). The current density of the samples during the SSRT was captured by a potentiostat, and used as an indicator to determine the susceptibility to SCC. Fractography was analyzed using scanning-electron microscopy (SEM). The experimental results showed that the laser-welded sample after PWHT was immune to the SCC as evidenced by the stable current density throughout the SSRT. This is attributed to the precipitation of fine and coherent nano-sized Ni4Ti3 precipitates in the welded regions (weld zone, WZ and heat-affected zone, HAZ) after PWHT, resulting in (i) enrichment of TiO2 content in the passive film and (ii) higher resistance against the local plastic deformation in the welded regions.
Resumo:
The plain fatigue and fretting fatigue tests of Ti-1023 titanium alloy were performed using a high-frequency push-pull fatigue testing machine. Both σmax versus number of cycles to failure curves were obtained for comparative analysis of the fretting effect on fatigue performance of the titanium alloy. Meanwhile, by analyzing the fracture of plain fatigue and fretting fatigue, the fretting scar and the fretting debris observed by scanning electron microscopy (SEM), the mechanism of fretting fatigue failure of Ti-1023 titanium alloy is discussed. The fretting fatigue strength of Ti-1023 titanium alloy is 175 MPa under 10 MPa contact pressure, which is 21% of plain fatigue strength (836 MPa). Under fretting condition, the Ti-1023 titanium alloy fatigue fracture failure occurs in a shorter fatigue life. When it comes to σmax versus number of cycles to failure curves, data points in the range of 106–107 cycles under plain fatigue condition moved to the range of 105–106 under fretting fatigue condition. The integrity of the fatigue specimen surface was seriously damaged under the effect of fretting. With the alternating stress loaded on specimen, the stress concentrated on the surface of fretting area, which brought earlier the initiation and propagation of crack.
Resumo:
Aim. To investigate (a) variability in powder/liquid proportioning and (b) effect of variability on diametral tensile strength (DTS), in a zinc phosphate cement. Statistical analyses (α = 0.05) were by Student's t-test in the case of powder/liquid ratio and one-way ANOVA and Tukey HSD for pair-wise comparisons of mean DTS. The Null hypotheses were that (a) the powder-liquid mixing ratios would not differ from the manufacturer's recommended ratio (b) DTS of the set cement samples using the extreme powder/liquid ratios would not differ from those made using the recommended ratio.
Methodology. 34 dental students dispensed the components according to the manufacturer's instructions. The maximum and minimum powder/liquid ratios, together with the manufacturer's recommended ratio, were used to prepare samples for DTS testing.
Results. Powder/liquid ratios ranged from 2.386 to 1.018. The mean ratio (1.644) was not significantly different from the recommended value of 1.718 (P = 0.189). DTS values for the maximum and minimum ratios were both significantly different from each other (P < 0.001) and from the mean value obtained from the recommended ratio (P < 0.001).
Conclusions. Variability exists in powder/liquid ratio for hand dispensed zinc phosphate cement. This variability can affect the DTS of the set material.
Resumo:
Like any new technology, tidal power converters are being assessed for potential environmental impacts. Similar to wind power, where noise emissions have led to some regulations and limitations on consented installation sites, noise emissions of these new tidal devices attract considerable attention, especially due to the possible interaction with the marine fauna. However, the effect of turbine noise cannot be assessed as a stand-alone issue, but must be investigated in the context of the natural background noise in high flow environments. Noise measurements are also believed to be a useful tool for monitoring the operating conditions and health of equipment. While underwater noise measurements are not trivial to perform, this non-intrusive mon- itoring method could prove to be very cost effective. This paper presents sound measurements performed on the SCHOTTEL Instream Turbine as part of the MaRINET testing campaign at the QUB tidal test site in Portaferry during the summer of 2014. This paper demonstrates a comparison of the turbine noise emissions with the normal background noise at the test site and presents possible applications as a monitoring system.
Resumo:
The redox catalyst ruthenium dioxide, prepared via the Adams technique, i.e.Ru(Adams), is used as a water oxidation catalyst using the oxidants (i) Ce(IV) in 0.5M H2SO4 and (ii) periodate in 0.5 M H2SO4, water and 0.1 M KOH. Like Ce(IV),periodate is a very strong oxidant that is able to oxidise water to oxygen and can bereadily monitored spectrophotometrically at 280 nm, compared with 430 nm for Ce(IV).More importantly, unlike Ce(IV), which is unstable towards hydrolysis above pH 1,periodate is stable in acid, water and strong alkali. A spectrophotometric study of thekinetics of periodate reduction, and concomitant oxidation of water to O2, reveals thatin the presence of a suitable redox catalyst, Ru(Adams) in this work, periodate is ableto effect the stoichiometric oxidation of water, with a turnover number > 64. In justwater, the kinetics of the latter reaction appear diffusion-controlled, due to the largethermodynamic driving force, a measure of which is the difference in redox potential,i.e. ∆E = 423 mV. As this difference is decreased, ∆E = 396 mV in acid and 290 mVin strong alkali (0.1 M KOH), the kinetics become increasingly activation-controlledand slower. These findings are discussed briefly with regard to the possible use of (i)periodate as an alternative oxidant in the rapid screening of new potential wateroxidation catalyst material powders that are stable only under near neutral and/oralkaline conditions, and (ii) Ru(Adams) as a benchmark catalyst.
Resumo:
Bioluminescence-based, solid-contact toxicity assays allow test bacterium and toxicant to interact at the solid-solution interface. A lux- marked bacterium, Burkholderia sp. RASC, and 2,4-dichlorophenol (2,4-DCP) were used to characterize these interactions. In the basic bioassay, cells were added to soil slurries containing 2,4-DCP (0-120 μg ml-1). After 15 min, soil was removed by centrifugation, and bioluminescence in the supernatant was determined. Investigation of 2,4-DCP adsorption to soil revealed that sorption was linear and not significantly (p > 0.1) affected by the presence of Burkholderia cells. The numbers of culturable Burkholderia cells in the assay supernatant were 48.2 to 64.8% of the inoculum and independent of the soil weight. The effect of soil on 2,4-DCP toxicity was investigated by comparing soil aqueous extract and contact assays. The percentage bioluminescence for the contact assay was consistently higher than the extract assay at all test concentrations, and counts of viable Burkholderia cells were enhanced by the presence of 2,4-DCP in the contact assay. Expressing results as specific bioluminescence decreased the variability in response and the discrepancy in results between the two protocols. We suggest that solid-contact assays need improvement to ensure defined contact between cells and solid phase, and that the reporting of specific activity should be emphasized.
Resumo:
High temperature ceramic membranes have interesting possibilities for application in areas of new and developing technologies such as hydrocarbon combustion with carbon dioxide capture and electrochemical promotion of catalysis (EPOC). However, membrane module sealing remains a significant technical challenge. In this work a borosilicate glass sealant (50SiO2·25B2O3·25Na2O, mol%) was developed to fit the requirements of sealing an air separation membrane system at intermediate temperatures (300-600 °C). The seal was assessed by testing the leak rates under a range of conditions. The parameters tested included the effect of flowrate on the leak rate, the heating and cooling rates of the reactor and the range of temperatures under which the system could operate. Tests for durability and reliability were also performed. It was found that the most favourable reactor configuration employed a reactor with the ceramic pellet placed underneath the inner chamber alumina tube (inverted configuration), using a quartz wool support to keep the membrane in place prior to sealing. Using this configuration the new glass-based seal was found to be a more suitable sealant than traditional alternatives; it produced lower leak rates at all desirable flowrates, with the potential for rapid heating and cooling and multiple cycling, allowing for prolonged usage. © 2010 Elsevier B.V. All rights reserved.
Resumo:
High density polyethylene (HDPE)/multi-walled carbon nanotube (MWCNT) composites containing 4 wt% MWCNTs were prepared by melt mixing followed by compression moulding into sheet. Compression moulded sheets were heated to just below the melting temperature and biaxially stretched at ratios (SRs) of 2, 2.5 and 3.0. The effect of stretching on the thermal and mechanical properties of the sheet was studied by differential scanning calorimetry (DSC) and tensile testing. DSC results show that the crystallinity of all the stretched samples increases by approximately 13% due to strain induced crystallization. The melting temperature of the biaxially stretched samples increases only slightly while crystallization temperature is not affected. Tensile test results indicate that at a SR of 2.5 the elastic modulus of the stretched composites increases by 17.6% relative to the virgin HDPE, but the breaking strength decreases by 33%. While the elastic modulus and breaking strength of the HDPE/MWCNT samples continue to increase as SR increases they drop off after a SR of 2.5 for the virgin HDPE. This is probably due to the constraining influence of the nanotubes preventing the relaxation of polymer chains caused by adiabatic heating at high SRs. The addition of MWCNTs results in significant strain hardening during deformation. While this will lead to increased energy requirement in forming it will also result in a more stable process and the ability to produce deep draw containers with more uniform wall thickness