Resumo:
Background: Digital pathology provides a digital environment for the management and interpretation of pathological images and associated data. It is becoming increasing popular to use modern computer based tools and applications in pathological education, tissue based research and clinical diagnosis. Uptake of this new technology is stymied by its single user orientation and its prerequisite and cumbersome combination of mouse and keyboard for navigation and annotation.
Methodology: In this study we developed SurfaceSlide, a dedicated viewing platform which enables the navigation and annotation of gigapixel digitised pathological images using fingertip touch. SurfaceSlide was developed using the Microsoft Surface, a 30 inch multitouch tabletop computing platform. SurfaceSlide users can perform direct panning and zooming operations on digitised slide images. These images are downloaded onto the Microsoft Surface platform from a remote server on-demand. Users can also draw annotations and key in texts using an on-screen virtual keyboard. We also developed a smart caching protocol which caches the surrounding regions of a field of view in multi-resolutions thus providing a smooth and vivid user experience and reducing the delay for image downloading from the internet. We compared the usability of SurfaceSlide against Aperio ImageScope and PathXL online viewer.
Conclusion: SurfaceSlide is intuitive, fast and easy to use. SurfaceSlide represents the most direct, effective and intimate human–digital slide interaction experience. It is expected that SurfaceSlide will significantly enhance digital pathology tools and applications in education and clinical practice.
Resumo:
Objective and design: Drug-induced adverse reactions can be allergic or pseudoallergic in nature, in this study the histamine releasing ability of 4 radiographic contrast media and 2 opioid analgesics was tested on a variety of mast cell containing cell suspensions.
Resumo:
Objectives: To determine the interobserver reliability of radiologists' interpretations of mobile chest radiographs for nursing home-acquired pneumonia. Design: A cross-sectional reliability study. Setting: Nursing homes and an acute care hospital. Participants: Four radiologists reviewed 40 mobile chest radiographs obtained from residents of nursing homes who met a clinical definition of lower respiratory tract infections. Measurements: Radiologists were asked to interpret radiographs with respect to the film quality; presence, pattern, and extent of an infiltrate; and the presence of a pleural effusion or adenopathy. Interrater reliability was evaluated using the intraclass correlation coefficient derived from a 2-way random effects model. Results: On average the radiologists reported that 6 of the 40 films were of very good or excellent quality and 16 of the 40 were of fair or poor quality. When the finding of an infiltrate was dichotomized (0 = no; 1 = possible, probable, or definite) all 4 radiologists agreed on 21 of the 37 chest radiographs. The intraclass correlation coefficient for the presence or absence of infiltrates was 0.54 (95% confidence intervals [CI] 0.38 to 0.69). For the 14 radiographs where infiltrates were observed by all radiologists, intraclass correlation coefficients for the presence of pleural effusions was 0.08 (95% CI -0.10 to 0.41), hilar adenopathy 0.54 (95% CI 0.29 to 0.79), and mediastinal adenopathy 0.49 (95% CI 0.21 to 0.76). Conclusion: In conclusion, the interrater agreement among radiologists for mobile chest radiographs in establishing the presence or absence of an infiltrate can be judged to be "fair." Treatment decisions need to include clinical findings and should not be made based on radiographic findings alone. © 2006 American Medical Directors Association.
Resumo:
This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.
Resumo:
Dental Panoramic Tomography (DPT) is a widely used and valuable examination in dentistry. One area prone to artefacts and therefore misinterpretation is the anterior region of the mandible. This case study discusses a periapical radiolucency related to lower anterior teeth that is discovered to be a radiographic artefact. Possible causes of the artefact include a pronounced depression in the mental region of the mandible or superimposition of intervertebral spaces. Additional limitations of the DPT image include superimposition of radio-opaque structures, reduced image detail compared to intra-oral views and uneven magnification. These problems often make the DPT inappropriate for imaging the anterior mandible.
CLINICAL RELEVANCE: Panoramic radiography is often unsuitable for radiographic examination of the anterior mandible.
Laser-driven x-ray and neutron source development for industrial applications of plasma accelerators
Resumo:
Pulsed beams of energetic x-rays and neutrons from intense laser interactions with solid foils are promising for applications where bright, small emission area sources, capable of multi-modal delivery are ideal. Possible end users of laser-driven multi-modal sources are those requiring advanced non-destructive inspection techniques in industry sectors of high value commerce such as aerospace, nuclear and advanced manufacturing. We report on experimental work that demonstrates multi-modal operation of high power laser-solid interactions for neutron and x-ray beam generation. Measurements and Monte Carlo radiation transport simulations show that neutron yield is increased by a factor ∼2 when a 1 mm copper foil is placed behind a 2 mm lithium foil, compared to using a 2 cm block of lithium only. We explore x-ray generation with a 10 picosecond drive pulse in order to tailor the spectral content for radiography with medium density alloy metals. The impact of using >1 ps pulse duration on laser-accelerated electron beam generation and transport is discussed alongside the optimisation of subsequent bremsstrahlung emission in thin, high atomic number target foils. X-ray spectra are deconvolved from spectrometer measurements and simulation data generated using the GEANT4 Monte Carlo code. We also demonstrate the unique capability of laser-driven x-rays in being able to deliver single pulse high spatial resolution projection imaging of thick metallic objects. Active detector radiographic imaging of industrially relevant sample objects with a 10 ps drive pulse is presented for the first time, demonstrating that features of 200 μm size are resolved when projected at high magnification.
Resumo:
Objectives: To determine the prevalence of untreated carious lesions in permanent teeth in patients (under the age of 18) referred for an orthodontic assessment in specialist practice. In addition, the figures shall be compared with national data for Northern Ireland (as outlined in the recent Child Dental Health Survey 2013)
The Gold standard would be that 100% of patients would be caries free upon presentation.
Methods: The clinical records and radiographs (OPT of quality grading 1 or 2) of 337 patients were reviewed. This encompassed patients who had an orthodontic assessment carried out in specialist practice over a 6 month period (following referral from their general dental practitioner)
Results: A total of 337 patient records were examined. Of these, 149 were male (44.2%) and 188 were female (55.8%), with an age range of 7-17 years at the time of new patient assessment. It was found that 36 patients (10.7%) had evidence (clinical and/or radiographic) of active and untreated dental caries. Of those affected, 14 were male and 22 were female.
Breaking the data down in terms of age, we can also get some indication as to how this cohort compares with national data for Northern Ireland :⃰
7-10 years (Mean = 9.3) = 14.3% caries (versus NI average of 6% for 8 year olds)
11-13 years (Mean = 12.1) = 10.1% caries, (versus NI average of 16% for 12 year olds)
14-17 years (Mean = 15.2) = 9.1% caries (versus NI average of 15% for 15 year olds)
⃰using the diagnostic threshold “Decay into dentine (visual dentine caries excluded)”
Conclusion: In this sample group, a total of 10.7% of patients (9.4% of males, 11.7% of females) presented with evidence of undiagnosed caries upon being assessed as a new patient in specialist orthodontic practice. Hence, the gold standard was not met.