31 resultados para physical function
Resumo:
A recent paper [L.-N. Hau and W.-Z. Fu, Phys. Plasmas 14, 110702 (2007)] deals with certain mathematical and physical properties of the kappa distribution. We comment on the authors' use of a form of distribution function that is different from the "standard" form of the kappa distribution, and hence their results, inter alia for an expansion of the distribution function and for the associated number density in an electrostatic potential, do not fully reflect the dependence on kappa that would be associated with the conventional kappa distribution. We note that their definition of the kappa distribution function is also different from a modified distribution based on the notion of nonextensive entropy.
Resumo:
Objective: To compare an accelerated intervention incorporating early therapeutic exercise after acute ankle sprains with a standard protection, rest, ice, compression, and elevation intervention.
Design: Randomised controlled trial with blinded outcome assessor.
Setting: Accident and emergency department and university based sports injury clinic.
Participants: 101 patients with an acute grade 1 or 2 ankle sprain.
Interventions: Participants were randomised to an accelerated intervention with early therapeutic exercise (exercise group) or a standard protection, rest, ice, compression, and elevation intervention (standard group).
Main outcome measures: The primary outcome was subjective ankle function (lower extremity functional scale). Secondary outcomes were pain at rest and on activity, swelling, and physical activity at baseline and at one, two, three, and four weeks after injury. Ankle function and rate of reinjury were assessed at 16 weeks.
Results: An overall treatment effect was in favour of the exercise group (P=0.0077); this was significant at both week 1 (baseline adjusted difference in treatment 5.28, 98.75% confidence interval 0.31 to 10.26; P=0.008) and week 2 (4.92, 0.27 to 9.57; P=0.0083). Activity level was significantly higher in the exercise group as measured by time spent walking (1.2 hours, 95% confidence interval 0.9 to 1.4 v 1.6, 1.3 to 1.9), step count (5621 steps, 95% confidence interval 4399 to 6843 v 7886, 6357 to 9416), and time spent in light intensity activity (53 minutes, 95% confidence interval 44 to 60 v 76, 58 to 95). The groups did not differ at any other time point for pain at rest, pain on activity, or swelling. The reinjury rate was 4% (two in each group).
Conclusion: An accelerated exercise protocol during the first week after ankle sprain improved ankle function; the group receiving this intervention was more active during that week than the group receiving standard care.
Resumo:
We present new optical and near-infrared (NIR) photometry and spectroscopy of the Type IIP supernova (SN), SN 2004et. In combination with already published data, this provides one of the most complete studies of optical and NIR data for any Type IIP SN from just after explosion to +500 d. The contribution of the NIR flux to the bolometric light curve is estimated to increase from 15 per cent at explosion to around 50 per cent at the end of the plateau and then declines to 40 per cent at 300 d. SN 2004et is one of the most luminous IIP SNe which has been well studied and characterized, and with a luminosity of log L = 42.3 erg s-1 and a 56Ni mass of 0.06 +/- 0.04 M-circle dot, it is two times brighter than SN 1999em. We provide parametrized bolometric corrections as a function of time since explosion for SN 2004et and three other IIP SNe that have extensive optical and NIR data. These can be used as templates for future events in optical and NIR surveys without full wavelength coverage. We compare the physical parameters of SN 2004et with those of other well-studied IIP SNe and find that the kinetic energies span a range of 1050-1051 erg. We compare the ejected masses calculated from hydrodynamic models with the progenitor masses and limits derived from pre-discovery images. Some of the ejected mass estimates are significantly higher than the progenitor mass estimates, with SN 2004et showing perhaps the most serious mass discrepancy. With the current models, it appears difficult to reconcile 100 d plateau lengths and high expansion velocities with the low ejected masses of 5-6 M-circle dot implied from 7-8 M-circle dot progenitors. The nebular phase is studied using very late-time Hubble Space Telescope photometry, along with optical and NIR spectroscopy. The light curve shows a clear flattening at 600 d in the optical and the NIR, which is likely due to the ejecta impacting on circumstellar material. We further show that the [O i] 6300, 6364 A line strengths in the nebular spectra of four Type IIP SNe imply ejected oxygen masses of 0.5-1.5 M-circle dot.
Resumo:
Experimental values for the carbon dioxide solubility in eight pure electrolyte solvents for lithium ion batteries – such as ethylene carbonate (EC), propylene carbonate (PC), dimethyl carbonate (DMC), ethyl methyl carbonate (EMC), diethyl carbonate (DEC), ?-butyrolactone (?BL), ethyl acetate (EA) and methyl propionate (MP) – are reported as a function of temperature from (283 to 353) K and atmospheric pressure. Based on experimental solubility data, the Henry’s law constant of the carbon dioxide in these solvents was then deduced and compared with reported values from the literature, as well as with those predicted by using COSMO-RS methodology within COSMOthermX software and those calculated by the Peng–Robinson equation of state implemented into Aspen plus. From this work, it appears that the CO2 solubility is higher in linear carbonates (such as DMC, EMC, DEC) than in cyclic ones (EC, PC, ?BL). Furthermore, the highest CO2 solubility was obtained in MP and EA solvents, which are comparable to the solubility values reported in classical ionicliquids. The precision and accuracy of the experimental values, considered as the per cent of the relative average absolute deviations of the Henry’s law constants from appropriate smoothing equations and from literature values, are close to (1% and 15%), respectively. From the variation of the Henry’s law constants with temperature, the partial molar thermodynamic functions of dissolution such as the standard Gibbs free energy, the enthalpy, and the entropy are calculated, as well as the mixing enthalpy of the solvent with CO2 in its hypothetical liquid state.
Resumo:
We present in this study the effect of nature and concentration of lithium salt, such as the lithium hexafluorophosphate, LiPF6; lithium tris(pentafluoroethane)-trifluorurophosphate LiFAP; lithium bis(trifluoromethylsulfonyl)imide, LiTFSI, on the CO2 solubility in four electrolytes for lithium ion batteries based on pure solvent that include ethylene carbonate (EC), dimethyl carbonate (DMC), ethyl methyl carbonate (EMC), diethyl carbonate (DEC), as well as, in the EC:DMC, EC:EMC and EC:DEC (50:50) wt.% binary mixtures as a function of temperature from (283 to 353) K and atmospheric pressure. Based on experimental solubility values, the Henry’s law constant of the carbon dioxide in these solutions with the presence or absence of lithium salt was then deduced and compared with reported values from the literature, as well as with those predicted by using COSMO-RS methodology within COSMOThermX software. From this study, it appears that the addition of 1 mol · dm-3 LiPF6 salt in alkylcarbonate solvents decreases their CO2 capture capacity. By using the same experimental conditions, an opposite CO2 solubility trend was generally observed in the case of the addition of LiFAP or LiTFSI salts in these solutions. Additionally, in all solutions investigated during this work, the CO2 solubility is greater in electrolytes containing the LiFAP salt, followed by those based on the LiTFSI case. The precision and accuracy of the experimental data reported therein, which are close to (1 and 15)%, respectively. From the variation of the Henry’s law constant with temperature, the partial molar thermodynamic functions of dissolution such as the standard Gibbs energy, the enthalpy, and the entropy, as well as the mixing enthalpy of the solvent with CO2 in its hypothetical liquid state were calculated. Finally, a quantitative analysis of the CO2 solubility evolution was carried out in the EC:DMC (50:50) wt.% binary mixture as the function of the LiPF6 or LiTFSI concentration in solution to elucidate how ionic species modify the CO2 solubility in alkylcarbonates-based Li-ion electrolytes by investigating the salting effects at T = 298.15 K and atmospheric pressure.
Resumo:
Herein we present a study on the physical/chemical properties of a new Deep Eutectic Solvent (DES) based on N-methylacetamide (MAc) and lithium bis[(trifluoromethyl)sulfonyl]imide (LiTFSI). Due to its interesting properties, such as wide liquid-phase range from -60°C to 280°C, low vapor pressure, and high ionic conductivity up to 28.4mScm at 150°C and at x=1/4, this solution can be practically used as electrolyte for electrochemical storage systems such as electric double-layer capacitors (EDLCs) and/or lithium ion batteries (LiBs). Firstly, relationships between its transport properties (conductivity and viscosity) as a function of composition and temperature were discussed through Arrhenius' Law and Vogel-Tamman-Fulcher (VTF) equations, as well as by using the Walden classification. From this investigation, it appears that this complex electrolyte possesses a number of excellent transport properties, like a superionic character for example. Based on which, we then evaluated its electrochemical performances as electrolyte for EDLCs and LiBs applications by using activated carbon (AC) and lithium iron phosphate (LiFePO) electrodes, respectively. These results demonstrate that this electrolyte has a good compatibility with both electrodes (AC and LiFePO) in each testing cell driven also by excellent electrochemical properties in specific capacitance, rate and cycling performances, indicating that the LiTFSI/MAc DES can be a promising electrolyte for EDLCs and LiBs applications especially for those requiring high safety and stability. © 2013 Elsevier Ltd.
Resumo:
We propose an interferometric setting for the ancilla-assisted measurement of the characteristic function of the work distribution following a time-dependent process experienced by a quantum system. We identify how the configuration of the effective interferometer is linked to the symmetries enjoyed by the Hamiltonian ruling the process and provide the explicit form of the operations to implement in order to accomplish our task. We finally discuss two physical settings, based on hybrid optomechanical-electromechanical devices, where the theoretical proposals discussed in our work could find an experimental demonstration.
Resumo:
The electro-oxidations of methanol and formic acid at a Ru(0001) electrode in perchloric acid solution have been investigated as functions of temperature, potential and time using in-situ FTIR spectroscopy, and the results compared to those obtained during our previous studies on the adsorption and electro-oxidation of CO under the same conditions. It was found that no dissociative adsorption or electro-oxidation of methanol takes place at the Ru(0001) at potentials 1000 mV, the oxidation of formic acid to CO was significantly increased, and the oxidation of methanol to CO and methyl formate was observed, both of which were attributed to the formation of an active RuO phase on the Ru(0001) surface.
Resumo:
In finite difference time domain simulation of room acoustics, source functions are subject to various constraints. These depend on the way sources are injected into the grid and on the chosen parameters of the numerical scheme being used. This paper addresses the issue of selecting and designing sources for finite difference simulation, by first reviewing associated aims and constraints, and evaluating existing source models against these criteria. The process of exciting a model is generalized by introducing a system of three cascaded filters, respectively, characterizing the driving pulse, the source mechanics, and the injection of the resulting source function into the grid. It is shown that hard, soft, and transparent sources can be seen as special cases within this unified approach. Starting from the mechanics of a small pulsating sphere, a parametric source model is formulated by specifying suitable filters. This physically constrained source model is numerically consistent, does not scatter incoming waves, and is free from zero- and low-frequency artifacts. Simulation results are employed for comparison with existing source formulations in terms of meeting the spectral and temporal requirements on the outward propagating wave.
Resumo:
Few research papers in economics have examined the extent, causes or consequences of physical stature decline in aging populations. Using repeated observations on objectively measured data from the English Longitudinal Study of Ageing (ELSA), we document that reduction in height is an important phenomenon among respondents aged 50 and over. On average, physical stature decline occurs at an annual rate of between 0.08% and 0.10% for males, and 0.12% and 0.14% for females—which approximately translates into a 2cm to 4cm reduction in height over the life course. Since height is commonly used as a measure of long-run health, our results demonstrate that failing to take age-related height loss into account substantially overstates the health advantage of younger birth cohorts relative to their older counterparts. We also show that there is an absence of consistent predictors of physical stature decline at the individual level. However, we demonstrate how deteriorating health and reductions in height occur simultaneously. We document that declines in muscle mass and bone density are likely to be the mechanism through which these effects are operating. If this physical stature decline is determined by deteriorating health in adulthood, the coefficient on measured height when used as an input in a typical empirical health production function will be affected by reverse causality. While our analysis details the inherent difficulties associated with measuring height in older populations, we do not find that significant bias arises in typical empirical health production functions from the use of height which has not been adjusted for physical stature decline. Therefore, our results validate the use of height among the population aged over 50.
Resumo:
We present an implementation of quantum annealing (QA) via lattice Green's function Monte Carlo (GFMC), focusing on its application to the Ising spin glass in transverse field. In particular, we study whether or not such a method is more effective than the path-integral Monte Carlo- (PIMC) based QA, as well as classical simulated annealing (CA), previously tested on the same optimization problem. We identify the issue of importance sampling, i.e., the necessity of possessing reasonably good (variational) trial wave functions, as the key point of the algorithm. We performed GFMC-QA runs using such a Boltzmann-type trial wave function, finding results for the residual energies that are qualitatively similar to those of CA (but at a much larger computational cost), and definitely worse than PIMC-QA. We conclude that, at present, without a serious effort in constructing reliable importance sampling variational wave functions for a quantum glass, GFMC-QA is not a true competitor of PIMC-QA.
Resumo:
Background
Chronic kidney disease is now regarded as a risk factor for cardiovascular disease. The impact of occupational or non-occupational physical activity (PA) on moderate decreases of renal function is uncertain.
ObjectivesWe aimed to identify the potential association of PA (occupational and leisure-time) on early decline of estimated glomerular filtration rate (eGFR) and to determine the potential mediating effect of PA on the relationship between eGFR and heart disease.
MethodsFrom the PRIME study analyses were conducted in 1058 employed men. Energy expended during leisure, work and commuting was calculated. Linear regression analyses were used to determine the link between types of PA and moderate decrements of eGFR determined with the KDIGO guideline at the baseline assessment. Cox proportional hazards analyses were used to explore the potential effect of PA on the relationship between eGFR and heart disease, ascertained during follow-up over 10 years.
ResultsFor these employed men, and after adjustment for known confounders of GFR change, more time spent sitting at work was associated with increased risk of moderate decline in kidney function, while carrying objects or being active at work was associated with decreased risk. In contrast, no significant link with leisure PA was apparent. No potential mediating effect of occupational PA was found for the relationship between eGFR and coronary heart disease.
ConclusionOccupational PA (potential modifiable factors) could provide a dual role on early impairment of renal function, without influence on the relationship between early decrease of e-GFR and CHD risk.
Resumo:
Gold nanoparticles (GNPs), have been demonstrated as effective preclinical radiosensitising agents in a range of cell models and radiation sources. These studies have also highlighted difficulty in predicted cellular radiobiological responses mediated by GNPs, based on physical assumptions alone, and therefore suggest a significant underlying biological component of response. This study aimed to determine the role of mitochondrial function in GNP radiosensitisation. Using assays of DNA damage and mitochondrial function through levels of oxidation and loss of membrane potential, we demonstrate a potential role of mitochondria as a central biological mechanism of GNP mediated radiosensitisation.
Resumo:
OBJECTIVE: To compare an accelerated intervention incorporating early therapeutic exercise after acute ankle sprains with a standard protection, rest, ice, compression, and elevation intervention.
DESIGN: Randomised controlled trial with blinded outcome assessor.
SETTING: Accident and emergency department and university based sports injury clinic.
PARTICIPANTS: 101 patients with an acute grade 1 or 2 ankle sprain.
INTERVENTIONS: Participants were randomised to an accelerated intervention with early therapeutic exercise (exercise group) or a standard protection, rest, ice, compression, and elevation intervention (standard group).
MAIN OUTCOME MEASURES: The primary outcome was subjective ankle function (lower extremity functional scale). Secondary outcomes were pain at rest and on activity, swelling, and physical activity at baseline and at one, two, three, and four weeks after injury. Ankle function and rate of reinjury were assessed at 16 weeks.
RESULTS: An overall treatment effect was in favour of the exercise group (P=0.0077); this was significant at both week 1 (baseline adjusted difference in treatment 5.28, 98.75% confidence interval 0.31 to 10.26; P=0.008) and week 2 (4.92, 0.27 to 9.57; P=0.0083). Activity level was significantly higher in the exercise group as measured by time spent walking (1.2 hours, 95% confidence interval 0.9 to 1.4 v 1.6, 1.3 to 1.9), step count (5621 steps, 95% confidence interval 4399 to 6843 v 7886, 6357 to 9416), and time spent in light intensity activity (53 minutes, 95% confidence interval 44 to 60 v 76, 58 to 95). The groups did not differ at any other time point for pain at rest, pain on activity, or swelling. The reinjury rate was 4% (two in each group).
CONCLUSION: An accelerated exercise protocol during the first week after ankle sprain improved ankle function; the group receiving this intervention was more active during that week than the group receiving standard care.
TRIAL REGISTRATION: Current Controlled Trials ISRCTN13903946.