40 resultados para oriented


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The contemporary dominance of visuality has turned our understanding of space into a mode of unidirectional experience that externalizes other sensual capacities of the body while perceiving the built environment. This affects not only architectural practice but also architectural education when an introduction to the concept of space is often challenging, especially for the students who have limited spatial and sensual training. Considering that an architectural work is not perceived as a series of retinal pictures but as a repeated multi-sensory experience, the problem definitions in the design studio need to be disengaged from the dominance of a ‘focused vision’ and be re-constructed in a holistic manner. A method to address this approach is to enable the students to refer to their own sensual experiences of the built environment as a part of their design processes. This paper focuses on a particular approach to the second year architectural design teaching which has been followed in the Department of Architecture at Izmir University of Economics for the last three years. The very first architectural project of the studio and the program, entitled ‘Sensing Spaces’, is conducted as a multi-staged design process including ‘sense games, analyses of organs and their interpretations into space’. The objectives of this four-week project are to explore the sense of space through the design of a three-dimensional assembly, to create an awareness of the significance of the senses in the design process and to experiment with re-interpreted forms of bodily parts. Hence, the students are encouraged to explore architectural space through their ‘tactile, olfactory, auditory, gustative and visual stimuli’. In this paper, based on a series of examples, architectural space is examined beyond its boundaries of structure, form and function, and spatial design is considered as an activity of re-constructing the built environment through the awareness of bodily senses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quality of single crystal diamond obtained by microwave CVD processes has been drastically improved in the last 5 years thanks to surface pretreatment of the substrates [A. Tallaire, J. Achard, F. Silva, R.S. Sussmann, A. Gicquel, E. Rzepka, Physica Status Solidi (A) 201, 2419-2424 (2004); G. Bogdan, M. Nesladek, J. D'Haen, J. Maes, V.V. Moshchalkov, K. Haenen, M. D'Olieslaeger, Physica Status Solidi (A) 202, 2066-2072 (2005); M. Yamamoto, T. Teraji, T. Ito, Journal of Crystal Growth 285, 130-136 (2005)]. Additionally, recent results have unambiguously shown the occurrence of (110) faces on crystal edges and (113) faces on crystal corners [F. Silva, J. Achard, X. Bonnin, A. Michau, A. Tallaire, O. Brinza, A. Gicquel, Physica Status Solidi (A) 203, 3049-3055 (2006)]. We have developed a 3D geometrical growth model to account for the final crystal morphology. The basic parameters of this growth model are the relative displacement speeds of (111), (110) and (113) faces normalized to that of the (100) faces, respectively alpha, beta, and gamma. This model predicts both the final equilibrium shape of the crystal (i.e. after infinite growth time) and the crystal morphology as a function of alpha, beta, gamma, and deposition time.

An optimized operating point, deduced from the model, has been validated experimentally by measuring the growth rate in (100), (111), (110), and (113) orientations. Furthermore, the evolution of alpha, beta, gamma as a function of methane concentration in the gas discharge has been established. From these results, crystal growth strategies can be proposed in order, for example, to enlarge the deposition area. In particular, we will show, using the growth model, that the only possibility to significantly increase the deposition area is, for our growth conditions, to use a (113) oriented substrate. A comparison between the grown crystal and the model results will be discussed and characterizations of the grown film (Photoluminescence spectroscopy, EPR, SEM) will be presented. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preterm infants in the neonatal intensive care unit undergo repeated exposure to procedural and ongoing pain. Early and long-term changes in pain processing, stress-response systems and development may result from cumulative early pain exposure. So that appropriate treatment can be given, accurate assessment of pain is vital, but is also complex because these infants' responses may differ from those of full-term infants. A variety of uni- and multidimensional assessment tools are available; however, many have incomplete psychometric testing and may not incorporate developmentally important cues. Near-infrared spectroscopy and/or EEG techniques that measure neonatal pain responses at a cortical level offer new opportunities to validate neonatal pain assessment tools.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To evaluate the diagnostic capability of tendency oriented perimetry (TOP) in glaucoma. METHODS. A): The diagnostic accuracy of mean defect (MD), square-root of the loss variance (sLV), and number of pathologic points (NPP) was calculated in 295 normal and 414 glaucoma eyes (179 early, 112 moderate, and 123 advanced) examined with TOP. B): Threshold fluctuation (F) and its relationship with the loss variance (LV) was measured in 34 normal and 33 glaucoma eyes (mean MD=3 dB; SD=3.9) for TOP and for full-threshold perimetry (FT). C): Twenty-eight eyes with stable glaucoma (mean MD=9.5 dB; SD=7.2) were examined six times to quantify LV error. D): TOP and FT were tested with the simulation program PeriSim using different behavior models. RESULTS. A): The best diagnostic index in early glaucoma (MD

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sensitivity and specificity of the screening mode of the Humphrey-Welch Allyn frequency-doubling technology (FDT), Octopus tendency-oriented perimetry (TOP), and the Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast (HSF) in patients with glaucoma. DESIGN: A comparative consecutive case series. METHODS: This was a prospective study which took place in the glaucoma unit of an academic department of ophthalmology. One eye of 70 consecutive glaucoma patients and 28 age-matched normal subjects was studied. Eyes were examined with the program C-20 of FDT, G1-TOP, and 24-2 HSF in one visit and in random order. The gold standard for glaucoma was presence of a typical glaucomatous optic disk appearance on stereoscopic examination, which was judged by a glaucoma expert. The sensitivity and specificity, positive and negative predictive value, and receiver operating characteristic (ROC) curves of two algorithms for the FDT screening test, two algorithms for TOP, and three algorithms for HSF, as defined before the start of this study, were evaluated. The time required for each test was also analyzed. RESULTS: Values for area under the ROC curve ranged from 82.5%-93.9%. The largest area (93.9%) under the ROC curve was obtained with the FDT criteria, defining abnormality as presence of at least one abnormal location. Mean test time was 1.08 ± 0.28 minutes, 2.31 ± 0.28 minutes, and 4.14 ± 0.57 minutes for the FDT, TOP, and HSF, respectively. The difference in testing time was statistically significant (P <.0001). CONCLUSIONS: The C-20 FDT, G1-TOP, and 24-2 HSF appear to be useful tools to diagnose glaucoma. The test C-20 FDT and G1-TOP take approximately 1/4 and 1/2 of the time taken by 24 to 2 HSF. © 2002 by Elsevier Science Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare the diagnostic abilities of the standard bracketing strategy (BR) and a fast strategy, the tendency-oriented perimetry (TOP). Methods: Seventy-seven controls and 91 eyes from patients with glaucoma were analyzed with the strategies TOP and BR. Sensitivity (Se), specificity (Sp), the area under the receiver operating characteristic (ROC) curve (AC) and the optimum cutoff value (CO) were calculated for the visual field indices mean defect (MD), the square root of the loss variance (sLV) and the number of pathological points (NPP). Results: In the glaucoma group, the mean MD value using TOP and BR was 7.5 and 8.3 dB, respectively. The mean sLV value using TOP and BR was 5.0 and 5.3 dB, respectively. Indices provided by TOP had higher ROC values than the ones provided by BR. Using TOP, the index with the best diagnostic ability was sLV (Sp = 94.8, Se = 90.1, AC = 0.966, CO = 2.5 dB), followed by NPP and MD. Using BR, the best results were obtained for MD (Sp = 92.2, Se = 81.3, AC = 0.900, CO = 2.5 dB) followed by sLV and NPP. Conclusions: A fast strategy, TOP, had superior diagnostic ability than the standard BR. Although TOP provided lower LV values than BR, the diagnostic ability of this index was higher than that of the conventional strategy. Copyright © 2005 S. Karger AG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Youth's risk for adjustment problems amid political violence is well documented, but outcomes vary widely, with many children functioning well. Accordingly, researchers are seeking to identify the mechanisms and conditions that contribute to children's adjustment, with an interest in understanding effects on children in terms of changes in the social contexts in which they live and the psychological processes engaged by these social ecologies. In this article, we look at the importance of studying many levels of the social ecology and of differentiating the effects of exposure to contexts of political versus nonpolitical violence, and we address theories about explanatory processes. We review research pertinent to these themes, including a six-wave longitudinal study on political violence and children in Northern Ireland.