56 resultados para liquid flow monitoring


Relevância:

40.00% 40.00%

Publicador:

Resumo:

An approximate analysis of gas absorption with instantaneous reaction in a liquid layer of finite thickness in plug flow is presented. An approximate solution to the enhancement factor for the case of unequal diffusivities between the dissolved gas and the liquid reactant has been derived and validated by numerical simulation. Depending on the diffusivity ratio of the liquid reactant to the dissolved gas (?), the enhancement factor tends to be either lower or higher than the prediction of the classical enhancement factor equation based on the penetration theory (Ei,pen) at Fourier numbers typically larger than 0.1. An empirical correlation valid for all Fourier numbers is proposed to allow a quick estimation of the enhancement factor, which describes the prediction of the approximate solution and the simulation data with a relative error below 5?% under the investigated conditions (? = 0.34, Ei,pen = 21000).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Gas absorption accompanied by an irreversible chemical reaction of first-order or second-order in a liquid layer of finite thickness in plug flow has been investigated. The analytical solution to the enhancement factor has been derived for the case of a first-order reaction, and the exact solution to the enhancement factor has been obtained via numerical simulation for the case of a second-order reaction. The enhancement factor in both cases is presented as a function of the Fourier number and tends to deviate from the prediction of the existing enhancement factor expressions based on the penetration theory at Fourier numbers above 0.1 due to the absence of a well-mixed bulk region in the liquid layer. Approximate enhancement factor expressions that describe the analytical and exact solutions with an accuracy of 5?% and 9?%, respectively, have been proposed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The peroxometalate-based polymer immobilized ionic liquid phase catalyst [PO4{WO(O-2)(2)}(4)]@PIILP has been prepared by anion exchange of ring opening metathesis-derived pyrrolidinium-decorated norbornene/ cyclooctene copolymer and shown to be a remarkably efficient system for the selective oxidation of sulfides under mild conditions. A cartridge packed with a mixture of [PO4{WO(O-2)(2)}(4)]@PIILP and silica operated as a segmented or continuous flow process and gave good conversions and high selectivity for either sulfoxide (92% in methanol at 96% conversion for a residence time of 4 min) or sulfone (96% in acetonitrile at 96% conversion for a residence time of 15 min). The immobilized catalyst remained active for 8 h under continuous flow operation with a stable activity/selectivity profile that allowed 6.5 g of reactant to be processed (TON = 46 428) while a single catalyst cartridge could be used for the consecutive oxidation of multiple substrates giving activity-selectivity profiles that matched those obtained with fresh catalyst.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A single-step lateral flow immunoassay was developed and validated to detect okadaic acid (OA) and dinophysis toxins (DTXs), which cause diarrhetic shellfish poisoning. The performance characteristics of the test were investigated, in comparison to reference methods (liquid chromatography tandem mass spectrometry and/or bioassay), using both spiked and naturally contaminated shellfish. A portable reader was used to generate a qualitative result, indicating the absence or presence of OA-group toxins, at concentrations relevant to the maximum permitted level (MPL). Sample homogenates could be screened in 20 min (including extraction and assay time) for the presence of free toxins (OA, DTX1, DTX2). DTX3 detection could be included with the addition of a hydrolysis procedure. No matrix effects were observed from the species evaluated (mussels, scallops, oysters, and clams). Results from naturally contaminated samples (n = 72) indicated no false compliant results and no false noncompliant results at <50% MPL. Thus, the development of a new low-cost but highly effective tool for monitoring a range of important phycotoxins has been demonstrated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Minimal residual disease (MRD) studies are useful in multiple myeloma (MM). However, the definition of the best technique and clinical utility are still unresolved issues. The aim of this study was to analyze and compare the clinical utility of MRD studies in MM with two different techniques: allelic-specific oligonucleotide real-time quantitative PCR (ASO-RQ-PCR), and flow cytometry (FCM). DESIGN AND METHODS: Bone marrow samples from 32 MM patients who had achieved complete response after transplantation were evaluated by ASO-RQ-PCR, using TaqMan technology, and multiparametric FCM. RESULTS: ASO-RQ-PCR was only applicable in 75% of patients for a variety of technical reasons, while FCM was applicable in up to 90%. Therefore, simultaneous PCR/FCM analysis was possible in only 24 patients. The number of residual tumor cells identified by both techniques was very similar (mean=0.29%, range=0.001-1.61%, correlation coefficient=0.861). However, RQ-PCR was able to detect residual myelomatous cells in 17 patients while FCM only did so in 11; thus, 6 cases were FCM negative but PCR positive, all of them displaying a very low number of clonal cells (median=0.014%, range=0.001-0.11). Using an MRD threshold of 0.01% (10(-4)) two risk groups with significantly different progression-free survival could be identified by either PCR (34 vs. 15m, p=0.04) or FCM (27 vs. 10m, p=0.05). INTERPRETATION AND CONCLUSIONS: Although MRD evaluation by ASO-RQ-PCR is slightly more sensitive and specific than FCM, it is applicable in a lower proportion of MM patients and is more time-consuming, while both techniques provide similar prognostic information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rimming flow on the inner surface of a horizontal rotating cylinder is investigated. Using a scale analysis, a theoretical description is obtained for steady-state non-Newtonian flow. Simple lubrication theory is applied since the Reynolds number is small and the liquid film is thin. Since the Deborah number is very small the flow is viscometric. The shear-thinning number, which characterizes the shear-thinning effect, may be small or large. A general constitutive law for this kind of flow requires only a single function relating shear stress and shear rate that corresponds to a generalized Newtonian liquid. For this case the run-off condition for rimming flow is derived. Provided the run-off condition is satisfied, the existence of a continuous steady-state solution is proved. The rheological models, which show Newtonian behavior at low shear rates with transition to power-law shear thinning at moderate shear rates, are considered. Numerical results are carried out for the Carreau and Ellis models, which exhibit Newtonian behavior near the free surface and power-law behavior near the wall of the rotating cylinder.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Liquid-liquid equilibria of two ternary mixtures 2M1B-2M1BOH-H[2]O] and 2M2B-2M1BOH-H[2]O were measured at 5, 15 and 25 C. UNIQUAC and NRTL models were fitted to the experimental data using ASPEN PLUS. Both experimental and correlated values of equilibrium compositions were compared with the values predicted by UNIFAC method. The same procedure was extended to the quaternary mixture 2M1B-2M2B-2M 1BOH-H[2]O. The regressed results were in good agreements with experimental data. Original UNIFAC model performed better representation than Dortmund UNIFAC model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article describes the development of SPE and HPLC methods for the simultaneous determination of metformin and glipizide, gliclazide, glibenclamide or glimperide in plasma. Several extraction and HPLC methods have been described previously for the determination of each of these analytes in plasma separately. The simultaneous determination of these analytes is important for the routine monitoring of diabetic patients who take combination medications and for studying the pharmacokinetics of the combined dosage forms. In addition this developed method can serve as a standard method for the plasma determination of these analytes therefore saving time, effort and money. The recoveries of the developed methods were found to be between 76.3% and 101.9%. The limits of quantification were between 5 and 22.5 ng/ml. The intraday and interday precision (measured by coefficient of variation, CV%) was always less than 9%. The accuracy (measured by relative error %) was always less than 12%. Stability analysis showed that all analytes are stable for at least 3 months when stored at -70degreesC. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurements on the diffusion coefficient of the neutral molecule N,N,N',N'-tetramethyl-para-phenylenediamine and the radical cation and dication generated by its one- and two-electron oxidation, respectively, are reported over the range 298-348 K in both acetonitrile and four room temperature ionic liquids (RTILs). Data were collected using single and double potential step chronamperometry at a gold disk electrode of micrometer dimension, and analysed via fitting to the appropriate analytical expression or, where necessary, to simulation. The variation of diffusion coefficient with temperature was found to occur in an Arrhenius-type manner for all combinations of solute and solvent. For a given ionic liquid, the diffusional activation energies of each species were not only closely equivalent to each other, but also to the RTIL's activation energy of viscous flow. In acetonitrile supported with 0.1 M tetrabutylammonium perchlorate, the ratio in diffusion coefficients of the radial cation and dication tot he neutral molecule were calculated as 0.89 +/- 0.05 and 0.51 +/- 0.03, respectively. In contrast, amongst the ionic liquids the same ratios were determined to be on average 0.53 +/- 0.04 and 0.33 +/- 0.03. The consequences of this dissimilarity are considered in terms of the modelling of voltammetric data gathered within ionic liquid solvents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A selective and sensitive liquid chromatography (LC)-atmospheric pressure chemical ionisation (APCI)-mass spectroscopic (MS) assay of canrenone has been developed and validated employing Dried Blood Spots (DBS) as the sample collection medium. DBS samples were prepared by applying 30 mu l of spiked whole blood onto Guthrie cards. A 6 mm disc was punched from the each DBS and extracted with 2 ml of methanolic solution of 17 alpha-methyltestosterone (Internal Standard). The methanolic extract was evaporated to dryness and reconstituted in acetonitrile:water (1:9, v/v). The reconstituted solution was further subjected to solid phase extraction using HLB cartridges. Chromatographic separation was achieved using Waters Sunfire C18 reversed-phase column using isocratic elution, followed by a high organic wash to clear late eluting/highly retained components. The mobile phase consisted of methanol:water (60:40, v/v) pumped at a flow rate of 0.3 ml/min. LC-APCI-MS detection was performed in the selected-ion monitoring (SIM) mode using target ions at m/z 341.1 and 303.3 for canrenone and internal standard respectively. The selectivity of the method was established by analysing DBS samples from 6 different sources (individuals). The calibration curve for canrenone was found to be linear over 25-1000 ng/ml (r >0.994). Accuracy (% RE) and precision (% CV) values for within and between day were

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid liquid chromatographic-tandem mass spectrometric (LC-MS/MS) multi-residue method for the simultaneous quantitation and identification of sixteen synthetic growth promoters and bisphenol A in bovine milk has been developed and validated. Sample preparation was straightforward, efficient and economically advantageous. Milk was extracted with acetonitrile followed by phase separation with NaCl. After centrifugation, the extract was purified by dispersive solid-phase extraction with C18 sorbent material. The compounds were analysed by reversed-phase LC-MS/MS using both positive and negative ionization and operated in multiple reaction monitoring (MRM) mode, acquiring two diagnostic product ions from each of the chosen precursor ions for unambiguous confirmation. Total chromatographic run time was less than 10 min for each sample. The method was validated at a level of 1 mu g L-1. A wide variety of deuterated internal standards were used to improve method performance. The accuracy and precision of the method were satisfactory for all analytes. The confirmative quantitative liquid chromatographic tandem mass spectrometric (LC-MS/MS) method was validated according to Commission Decision 2002/657/EC. The decision limit (CC alpha) and the detection capability (CC beta) were found to be below the chosen validation level of 1 mu g L-1 for all compounds. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study concerns the spatial allocation of material flows, with emphasis on construction material in the Irish housing sector. It addresses some of the key issues concerning anthropogenic impact on the environment through spatial temporal visualisation of the flow of materials, wastes and emissions at different spatial levels. This is presented in the form of a spatial model, Spatial Allocation of Material Flow Analysis (SAMFA), which enables the simulation of construction material flows and associated energy use. SAMFA parallels the Island Limits project (EPA funded under 2004-SD-MS-22-M2), which aimed to create a material flow analysis of the Irish economy classified by industrial sector. SAMFA further develops this by attempting to establish the material flows at the subnational geographical scale that could be used in the development of local authority (LA) sustainability strategies and spatial planning frameworks by highlighting the cumulative environmental impacts of the development of the built environment. By drawing on the idea of planning support systems, SAMFA also aims to provide a cross-disciplinary, integrative medium for involving stakeholders in strategies for a sustainable built environment and, as such, would help illustrate the sustainability consequences of alternative The pilot run of the model in Kildare has shown that the model can be successfully calibrated and applied to develop alternative material flows and energy-use scenarios at the ED level. This has been demonstrated through the development of an integrated and a business-as-usual scenario, with the former integrating a range of potential material efficiency and energysaving policy options and the latter replicating conditions that best describe the current trend. Their comparison shows that the former is better than the latter in terms of both material and energy use. This report also identifies a number of potential areas of future research and areas of broader application. This includes improving the accuracy of the SAMFA model (e.g. by establishing actual life expectancy of buildings in the Irish context through field surveys) and the extension of the model to other Irish counties. This would establish SAMFA as a valuable predicting and monitoring tool that is capable of integrating national and local spatial planning objectives with actual environmental impacts. Furthermore, should the model prove successful at this level, it then has the potential to transfer the modelling approach to other areas of the built environment, such as commercial development and other key contributors of greenhouse emissions. The ultimate aim is to develop a meta-model for predicting the consequences of consumption patterns at the local scale. This therefore offers the possibility of creating critical links between socio technical systems with the most important challenge of all the limitations of the biophysical environment.