59 resultados para international election monitoring
Resumo:
Weathering of stone is one of the major reasons for the damage of stone masonry structures and it takes place due to interlinked chemical, physical and biological processes in stones. The key parameters involved in the deterioration processes are temperature, moisture and salt. It is now known that the sudden variations in temperature and moisture greatly accelerate the weathering process of the building stone fabric. Therefore, in order to monitor these sudden variations an effective and continuous monitoring system is needed. Furthermore, it must consist of robust sensors which are accurate and can survive in the harsh environments experienced in and around masonry structures. Although salt penetration is important for the rate of deterioration of stone masonry structures, the processes involved are much slower than the damage associated with temperature and moisture variations. Therefore, in this paper a novel fibre optic temperature cum relative humidity sensor is described and its applicability in monitoring building stones demonstrated. The performance of the sensor is assessed in an experiment comprising wetting and drying of limestone blocks. The results indicate that the novel fibre optic relative humidity sensor which is tailor made for applications in masonry structures performed well in wetting and drying tests, whilst commercial capacitance based sensors failed to recover during the drying regime for a long period after a wetting regime. That is, the fibre optic sensor has the capability to measure both sorption and de-sorption characteristics of stone blocks. This sensor is used in a test wall in Oxford and the data thus obtained strengthened the laboratory observations.
Resumo:
This article provides an overview of a novel prototype device that can be used to aid airports in monitoring their landing lighting. Known as Aerodrome Ground Lighting (AGL), the device is comprised of a camera that is capable of capturing images of landing lighting as aircraft approach the airport. AGL is designed to automatically examine landing lighting to assess if it is operating under uniform brightness standards (i.e., luminous intensity of luminares) that aviation governing bodies require. A detailed discussion of the hardware and software requirements of AGL -- currently under joint development by researchers at Queens University Belfast and Cobham Flight Inspection Limited -- is presented. Results from the research indicate that assessing the performance of both ground-based runway luminaries and elevated approach luminaries is possible, though further testing is needed for full validation.
Resumo:
This article investigates the link between regionalization of the structure of government, regional elections and regionalism on the one hand, and the organization of state-wide political parties in Spain and the UK on the other. It particularly looks at two aspects of the relations between the central and regional levels of party organization: integration of the regional branches in central decision making and autonomy of the regional branches. It argues that the party factors are the most crucial elements explaining party change and that party leaders mediate between environmental changes and party organization. The parties' history and beliefs and the strength of the central leadership condition their ability or willingness to facilitate the emergence of meso-level elites. The institutional and electoral factors are facilitating factors that constitute additional motives for or against internal party decentralization.
Resumo:
While WiFi monitoring networks have been deployed in previous research, to date none have assessed live network data from an open access, public environment. In this paper we describe the construction of a replicable, independent WLAN monitoring system and address some of the challenges in analysing the resultant traffic. Analysis of traffic from the system demonstrates that basic traffic information from open-access networks varies over time (temporal inconsistency). The results also show that arbitrary selection of Request-Reply intervals can have a significant effect on Probe and Association frame exchange calculations, which can impact on the ability to detect flooding attacks.
Resumo:
The global increase in the penetration of renewable energy is pushing electrical power systems into uncharted territory, especially in terms of transient and dynamic stability. In particular, the greater penetration of wind generation in European power networks is, at times, displacing a significant capacity of conventional synchronous generation with fixed-speed induction generation and now more commonly, doubly-fed induction generators. The impact of such changes in the generation mix requires careful monitoring to assess the impact on transient and dynamic stability. This paper presents a measurement based method for the early detection of power system oscillations, with attention to mode damping, in order to raise alarms and develop strategies to actively improve power system dynamic stability and security. A method is developed based on wavelet transform and support vector data description (SVDD) to detect oscillation modes in wind farm output power, which may excite dynamic instabilities in the wider system. The wavelet transform is used as a filter to identify oscillations in different frequency bands, while SVDD is used to extract dominant features from different scales and generate an assessment boundary according to the extracted features. Poorly damped oscillations of a large magnitude or that are resonant can be alarmed to the system operator, to reduce the risk of system instability. Method evaluation is exemplified used real data from a chosen wind farm.
Resumo:
This paper examines power quality benchmarks in the electricity supply industry (ESI) and impact of standards for the reduction of voltage dip incidents. The paper considers adherence to particular standards and is supported by several case studies from incidents where voltage dips have been detected and assessed by the power systems division of Scottish Power and where improvements have been implemented to help militate against subsequent incidents.