43 resultados para fund performance evaluation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The government of the UK has set an ambitious target that all newly built homes be carbon neutral by 2016 and to achieving an overall 80% carbon emission by 2050. Carbon Trust in 2009 published a research revealing that non-domestic buildings accounted for 18% of the emissions in the UK. They argued that to achieve the targets of low carbon emission there is need for better building stock that are better used. The evaluation of the performance of buildings is therefore critical if the understanding of how they are used is to be known. This paper is a brief building performance evaluation of the newly build library at Queens University Belfast carried out during the summer of 2010. It employed the Post-Occupancy Evaluation (POE) methodology to assess its performance. The results reveal that despite the intelligent technologies in the building there was a mismatch between the measured data and the perception of users of its performance. The study suggests the need for further study for reasons of dichotomy of the data. Keywords: building performance evaluation, carbon reduction strategies, passive environmental design techniques, active renewable energy technologies, Northern Ireland

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent theoretical investigations of spatially correlated multitransmit and multireceive (MTMR) links show that not only independently and identically distributed links, but also spatially correlated links can offer linear capacity growth with increasing number of transmit and receive antennas. In this paper, we explore the suitability of the turbo-BLAST architecture in correlated Rayleigh-fading MTMR environments. In particular, for an MTMR system with a large number of receive antennas, a near optimal performance can be achieved by the turbo-BLAST architecture in spatially and temporarily correlated Rayleigh-fading environments. The performance of turbo-BLAST, in terms of both bit-error rate and spectral efficiency, is analyzed empirically in indoors and correlated outdoor environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper the authors propose a new technique for determining a confidence factor applied to the performance prediction of individual luminaires within an overall pattern of luminaires. This work has relevance to any application where it is necessary to determine the performance of a lighting pattern e.g. street lighting, signal lighting etc. In this paper we apply our technique to a transportation application, namely, an airport landing lighting pattern. In the aviation industry it is imperative that the landing lighting pattern at individual airports performs according to standards. We have developed an automated technique which can be used to access the performance of luminaires within this pattern. We extend this work to also derive a confidence factor related to this prediction based on the quality of the data being utilised. ©2010 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study explores the application of a two-stage electrokinetic washing system on remediation of lead (Pb) contaminated soil. The process involved an initial soil washing, followed by an electrokinetic process. The use of electrokinetic process in soil washing not only provided additional driving force for transporting the desorbed Pb away from the soil but also reduced the high usage of wash solution. In this study, the effect of NaNO3, HNO3, citric acid and EDTA as wash solutions on two-stage electrokinetic washing system were evaluated. The results revealed that a two-stage electrokinetic washing process enhanced Pb removal efficiency by 2.52-9.08% and 4.98-20.45% in comparison to a normal electrokinetic process and normal washing process, respectively. Low pH and adequate current were the most important criteria in the removal process as they provided superior desorption and transport properties. The effect of chelating by EDTA was less dominant as it delayed the removal process by forming a transport loop in anode region between Pb ion and complexes. HNO3 was not suitable as wash solution in electrokinetic washing in spite of offering highest removal efficiency as it caused pH fluctuation in the cathode chamber, corroded graphite anode and showed high power consumption. In contrast, citric acid not only yielded high Pb removal efficiency with low power consumption but also maintained a low soil: solution ratio of 1 g: <1 mL, stable pH and electrode integrity. Possible transport mechanisms for Pb under each wash solution are also discussed in this work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Approximately half of the houses in Northern Ireland were built before any form of minimum thermal specification or energy efficiency standard was enforced. Furthermore, 44% of households are categorised as being in fuel poverty; spending more than 10% of the household income to heat the house to bring it to an acceptable level of thermal comfort. To bring existing housing stock up to an acceptable standard, retrofitting for improving the energy efficiency is essential and it is also necessary to study the effectiveness of such improvements in future climate scenarios. This paper presents the results from a year-long performance monitoring of two houses that have undergone retrofits to improve energy efficiency. Using wireless sensor technology internal temperature, humidity, external weather, household gas and electricity usage were monitored for a year. Simulations using IES-VE dynamic building modelling software were calibrated using the monitoring data to ASHARE Guideline 14 standards. The energy performance and the internal environment of the houses were then assessed for current and future climate scenarios and the results show that there is a need for a holistic balanced strategy for retrofitting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For Variable Stiffness (VS) composites with steered curvilinear tow paths, the fiber orientation angle varies continuously throughout the laminate, and is not required to be straight, parallel and uniform within each ply as in conventional composite laminates. Hence, the thermal properties (conduction), as well as the structural stiffness and strength, vary as functions of location in the laminate, and the associated composite structure is often called a “variable stiffness” composite structure. The steered fibers lead not only to the alteration of mechanical load paths, but also to the alteration of thermal paths that may
result in favorable temperature distributions within the laminate and improve the laminate performance. Evaluation of VS laminate performance under thermal loading is the focus of this chapter. Thermal performance evaluations require experimental and numerical analysis of VS laminates under different processing and loading conditions. One of the advantages of using composite materials in many applications is the tailoring capability of the laminate,
not only during the design phase but also for manufacturing. Heat transfer through variable conduction and chemical reaction (degree of cure) occurring during manufacturing (curing) plays an important role in the final thermal and mechanical performance, and shape of composite structures.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Approximately half of the houses in Northern Ireland were built before any form of minimum thermal specification (U-value) or energy efficiency standard were available. At present, 44% of households are categorised as being in fuel poverty; spending more than 10% of the household income to heat the house to an acceptable level. This paper presents the results from long term performance monitoring of 4 case study houses that have undergone retrofits to improve energy efficiency in Northern Ireland. There is some uncertainty associated with some of the marketed retrofit measures in terms of their effectiveness in reducing energy usage and their potential to cause detrimental impacts on the internal environment of a house. Using wireless sensor technology internal conditions such as temperature and humidity were measured alongside gas and electricity usage for a year. External weather conditions were also monitored. The paper considers the effectiveness of the different retrofit measures implemented based on the long term data monitoring and short term building performance evaluation tests that were completed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study considers a dual-hop cognitive inter-vehicular relay-assisted communication system where all
communication links are non-line of sight ones and their fading is modelled by the double Rayleigh fading distribution.
Road-side relays (or access points) implementing the decode-and-forward relaying protocol are employed and one of
them is selected according to a predetermined policy to enable communication between vehicles. The performance of
the considered cognitive cooperative system is investigated for Kth best partial and full relay selection (RS) as well as
for two distinct fading scenarios. In the first scenario, all channels are double Rayleigh distributed. In the second
scenario, only the secondary source to relay and relay to destination channels are considered to be subject to double
Rayleigh fading whereas, channels between the secondary transmitters and the primary user are modelled by the
Rayleigh distribution. Exact and approximate expressions for the outage probability performance for all considered RS
policies and fading scenarios are presented. In addition to the analytical results, complementary computer simulated
performance evaluation results have been obtained by means of Monte Carlo simulations. The perfect match between
these two sets of results has verified the accuracy of the proposed mathematical analysis.