73 resultados para enzymatic biosensor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several potential approaches to the enzyme-catalysed synthesis of arene trans-diols have been examined including epoxidation/hydrolysis, bis-benzylic hydroxylation, cis-dihydroxylation/alcohol dehydrogenation/ketone reduction, cisdihydroxylation/cis-trans isomerisation. and multi-enzyme synthesis of trans-dihydrodiol secondary metabolites from primary metabolites. The lack of general applicability of these enzymatic methods has led to the development of several chemoenzymatic routes for the synthesis of a series of trans-dihydrodiols from the readily available cis-dihydrodiol precursors. Partial hydrogenation of cis-dihydrodiol metabolites to yield the corresponding cis-tetrahydrodiols followed by a regioselective Mitsunobu inversion process gave trans-tetrahydrodiols that were in turn converted to trans-dihydrodiols. The formation of anti-benzene dioxides or iron tricarbonyl complexes from the corresponding cis-dihydrodiol precursors provided shorter and more convenient chemoenzymatic routes to trans-dihydrodiols. The application of cis-dihydrodiol metabolites of polycyclic azaarenes in the synthesis of the corresponding arene oxides followed by chemical hydrolysis provides a convenient route to trans-dihydrodiols. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chitins produced via a conventional chemical route as well as from a new biological process were modified to increase the efficiency of enzymatic deacetylation reactions for the production of novel biological chitosan. These modified chitins were reacted for 24h with extracellular fungal enzymes from Colletotrichum lindemuthianum. The chemical and physical properties of the various substrates were analysed and their properties related to the effectiveness in the deacetylation reaction. Modifications of the chitins affected the degree of deacetylation with varied effects. Without further modification to reduce crystallinity and to open up the solid substrate structure, the chitins were found to be poor substrates for the heterogeneous solid-liquid enzymatic catalysis. It was found that the solvent and drying method used in modifying the chitins had significant impact on the final efficiency of the enzymatic deacetylation reaction. The most successful modifications through freeze drying of a colloidal chitin suspension increased the degree of enzymatic deacetylation by 20 fold. These processes reduce the crystallinity of the chitin making it easier for the enzymes to access their internal structure. X-ray diffraction, scanning electron microscopy, thermogravimetric analysis, and BET isotherm analysis are employed to characterise the modified chitins to ascertain the degree of crystallinity, porous structure, surface area, and morphology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The phnA gene that encodes the carbon-phosphorus bond cleavage enzyme phosphonoacetate hydrolase is widely distributed in the environment, suggesting that its phosphonate substrate may play a significant role in biogeochemical phosphorus cycling. Surprisingly, however, no biogenic origin for phosphonoacetate has yet been established. To facilitate the search for its natural source we have constructed a whole-cell phosphonoacetate biosensor. The gene encoding the LysR-type transcriptional activator PhnR, which controls expression of the phosphonoacetate degradative operon in Pseudomonas fluorescens 23F, was inserted in the broad-host-range promoter probe vector pPROBE-NT, together with the promoter region of the structural genes. Cells of Escherichia coli DH5a that contained the resultant construct, pPANT3, exhibited phosphonoacetate-dependent green fluorescent protein fluorescence in response to threshold concentrations of as little as 0.5 µM phosphonoacetate, some 100 times lower than the detection limit of currently available non-biological analytical methods; the pPANT3 biosensor construct in Pseudomonas putida KT2440 was less sensitive, although with shorter response times. From a range of other phosphonates and phosphonoacetate analogues tested, only phosphonoacetaldehyde and arsonoacetate induced green fluorescent protein fluorescence in the E. coli DH5a (pPANT3) biosensor, although at much-reduced sensitivities (50 µM phosphonoacetaldehyde and 500 µM arsonoacetate).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface plasmon resonance (SPR) based biosensor technology has been widely used in life science research for many applications. While the advantages of speed, ruggedness, versatility, sensitivity and reproducibility are often quoted, many researchers have experienced severe problem of non-specific binding (NSB) to chip surfaces when performing analysis of biological samples Such as bovine serum. Using the direct measurement of the bovine protein leptin, present in bovine serum samples as a model, a unique buffering system has been developed and optimised which was able to significantly reduce the non-specific interactions of bovine serum components with the carboxymethyl dextran chip (CM5) surface on a Biacore SPR The developed NSB buffering system comprised of HBS-EP buffer, containing 0.5 M NaCl, 0.005% CM-dextran pH 9.0. An average NSB reduction (n = 20) of 85.9% and 87.3% was found on an unmodified CM5 surface and a CM5 with bovine leptin immobilised on the chip surface, respectively. A reduction in NSB of up to 94% was observed on both surfaces. The concentration of the constitutive components and pH of the buffer were crucial in achieving this outcome. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid analytical optical biosensor-based immunoassay was developed and validated for the detection of okadaic acid (OA) and its structurally related toxins from shellfish matrix. The assay utilizes a monoclonal antibody which binds to the OA group of toxins in order of their toxicities, resulting in a pseudofunctional assay. Single-laboratory validation of the assay for quantitative detection of OA determined that it has an action limit of 120 mu g/kg, a limit of detection of 31 mu g/kg, and a working range of 31-174 mu g/kg. The midpoint on the standard matrix calibration curve is 80 mu g/kg, half the current regulatory limit. Inter- and intra-assay studies of negative mussel samples spiked with various OA concentrations produced average coefficient of variation (CV) and standard deviation (SD) values of 7.9 and 10.1, respectively. The assay was also validated to confirm the ability to accurately codetect and quantify dinophysistoxin-1 (DTX-1), DTX-2, and DTX-3 from shellfish matrix. Alkaline hydrolysis was not required for the detection of DTX-3 from matrix. Excellent correlations with the data generated by the biosensor method and liquid chromatography/tandem mass spectrometry (LC/MS/MS) were obtained using a certified reference material (R-2 = 0.99), laboratory reference material, and naturally contaminated mussel samples (R-2 = 0.97). This new procedure could be used as a rapid screening procedure replacing animal-based tests for DSP toxins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A research element of the European Union (EU) sixth Framework project BioCop focused on the development of a surface plasmon resonance (SPR) biosensor assay for the detection of paralytic shellfish poisoning (PSP) toxins in shellfish as an alternative to the increasingly ethically unacceptable mouse bioassay. A biosensor assay was developed using both a saxitoxin binding protein and chip surface in tandem with a highly efficient simple extraction procedure. The present report describes the single laboratory validation of this immunological screening method, for this complex group of toxins with differing toxicities, according to the European Decision 2002/657/EC in conjunction with IUPAC and AOAC single laboratory validation guidelines. The different performance characteristics (detection capability CC beta, specificity/selectivity, repeatability, reproducibility, stability, and applicability) were determined in relation to the EU regulatory limit of 800 mu g of saxitoxin equivalents (STX eq) per kg of shellfish meat. The detection capability CC beta was calculated to be 120 mu g/kg. Intra-assay repeatability was found to be between 2.5 and 12.3% and interassay reproducibility was between 6.1 and 15.2% for different shellfish matrices. Natural samples were also evaluated and the resultant data displayed overall agreements of 96 and 92% with that of the existing AOAC approved methods of mouse bioassay (MBA) and high performance liquid chromatography (HPLC), respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tiamulin (TIA) is an antimicrobial veterinary drug administered subtherapeutically to prevent swine dysentery and pneumonia. Due to its stability, crystalline structure, and water-soluble properties, TIA is a prime candidate for environmental monitoring. However, there are currently no screening methods available for TIA in environmental matrices, such as grass or ground water. In this paper, the development and validation of a screening method using optical SPR biosensor technology is presented. A solvent extraction was carried out on samples prior to analysis using the Biacore Q instrument. The limit of detection for the assay in grass and ground water was 10.8 ng/g and 2.4 ng/ml, respectively. In addition, the assay was shown to be of an acceptable standard with regard to both accuracy and reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ractopamine (RCT) is a member of the beta-2-agonist (beta-agonist) family. It is licensed for use as an animal growth promoter in more than 20 countries worldwide, including the United States and Canada, but is either not licensed or prohibited by over 150 others, including those within the European Union. The issue of the use of RCT in livestock bound for human consumption has risen to prominence recently following the decision by The People's Republic of China to ban the import of pork from a number of processing plants after finding traces of RCT in shipments from the U.S.A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paralytic shellfish poisoning (PSP) toxin monitoring in shellfish is currently performed using the internationally accredited AOAC mouse bioassay. Due to ethical and performance-related issues associated with this bioassay, the European Commission has recently published directives extending procedures that may be used for official PSP control. The feasibility of using a surface plasmon resonance optical biosensor to detect PSP toxins in shellfish tissue below regulatory levels was examined. Three different PSP toxin protein binders were investigated: a sodium channel receptor (SCR) preparation derived from rat brains, a monoclonal antibody (GT13-A) raised to gonyautoxin 2/3, and a rabbit polyclonal antibody (R895) raised to saxitoxin (STX). Inhibition assay formats were used throughout. Immobilization of STX to the biosensor chip surface was achieved via amino-coupling. Specific binding and inhibition of binding to this surface was achieved using all proteins tested. For STX calibration curves, 0 - 1000 ng/mL, IC50 values for each binder were as follows: SCR 8.11 ng/mL; GT13-A 5.77 ng/mL; and R895 1.56 ng/mL. Each binder demonstrated a different cross-reactivity profile against a range of STX analogues. R895 delivered a profile that was most likely to detect the widest range of PSP toxins at or below the internationally adopted regulatory limits.