31 resultados para cofenetic correlation coefficient


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two case studies are presented in this paper to demonstrate the impact of different power system operation conditions on the power oscillation frequency modes in the Irish power system. A simplified 2 area equivalent of the Irish power system has been used in this paper, where area 1 represents the Republic of Ireland power system and area 2 represents the Northern Ireland power system.

The potential power oscillation frequency modes on the interconnector during different operation conditions have been analysed in this paper. The main objective of this paper is to analyse the influence of different operation conditions involving wind turbine generator (WTG) penetration on power oscillation frequency modes using phasor measurement unit (PMU) data.

Fast Fourier transform (FFT) analysis was performed to identify the frequency oscillation mode while correlation coefficient analysis was used to determine the source of the frequency oscillation. The results show that WTG, particularly fixed speed induction generation (FSIG), gives significant contribution to inter-area power oscillation frequency modes during high WTG operation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Previous investigators have not described some of the new anatomic variations or provided quantitative and analytical data of the arterial anatomy of the lips in as much depth as in this study. Dissections of 14 different facial sides of cadavers were done. Through investigating the arterial supply of the upper and lower lips, measurements were performed and statistically analyzed. The main arterial supply of the upper lip was from the superior labial artery (SLA, mean external diameter, 1.8 mm [SD, 0.74 mm]); in addition, the subalar and septal branches contributed to its vascularization. The origin of the SLA was above the labial commissure in 78.6%. The subalar branch was not found but replaced by the alar artery that arose from the infraorbital artery in 1 specimen. The main arterial supply of the lower lip was derived from 3 branches of the facial artery, the inferior labial artery (mean external diameters, 1.4 mm [SD, 0.31 mm]) and the horizontal and vertical labiomental arteries. The inferior labial artery originated mostly below the labial commissure in 42.9% and formed a common trunk with the SLA in 28.6%. The horizontal labiomental artery was present in all, but vertical labiomental artery was absent in 21.4% of specimens. Overall, observed anatomic variations were classified into types I to VIII. Significant relations between the demographic variables and measured parameters were reported including the correlation coefficient among evaluated parameters. In conclusion, this study provides various information that aids in creating new flaps and supports the vascular base for clinical procedures in reconstructive surgery of the lip.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The ability to exchange keys between users is vital in any wireless based security system. A key generation technique exploits the randomness of the wireless channel is a promising alternative to existing key distribution techniques, e.g., public key cryptography. In this paper a secure key generation scheme based on the subcarriers’ channel responses in orthogonal frequencydivision multiplexing (OFDM) systems is proposed. We first implement a time-variant multipath channel with its channel impulse response modelled as a wide sense stationary (WSS) uncorrelated scattering random process and demonstrate that each subcarrier’s channel response is also a WSS random process. We then define the X% coherence time as the time required to produce an X% correlation coefficient in the autocorrelation function (ACF) of each channel tap, and find that when all the channel taps have the same Doppler power spectrum, all subcarriers’ channel responses has the same ACF as the channel taps. The subcarrier’s channel response is then sampled every X% coherence time and quantized into key bits. All the key sequences’ randomness is tested using National Institute of Standards and Technology (NIST) statistical test suite and the results indicate that the commonly used sampling interval as 50% coherence time cannot guarantee the randomness of the key sequence.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel dual-band printed diversity antenna is proposed and studied. The antenna, which consists of two back-to- back monopoles with symmetric configuration, is printed on a printed circuit board. The effects of some important parameters of the proposed antenna are deeply studied and the design methodology is given. A prototype of the proposed antenna operating at UMTS (1920-2170 MHz) and 2.4-GHz WLAN (2400-2484 MHz) bands is provided to demonstrate the usability of the methodology in dual-band diversity antenna for mobile terminals. In the above two bands, the isolations of the prototype are larger than 13 dB and 16 dB, respectively. The measured radiation patterns of the two monopoles in general cover complementary space regions. The diversity performance is also evaluated by calculating the envelope correlation coefficient, the mean effective gains of the antenna elements and the diversity gain. It is proved that the proposed antenna can provide spatial and pattern diversity to combat multipath fading.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: The World Health Organisation has highlighted the paucity of research into the oral health needs of older adults. In particular, the relationships between oral health and nutritional status require further investigation and analysis. This study aimed to describe some of the relationships between the number of remaining occluding tooth contacts, oral health related quality of life and nutritional status of partially dentate older adults.

Methods: 45 partially dentate patients aged 65 years and older were recruited to the study after visiting a university dental hospital. An initial dental examination charted the remaining teeth including the number of occluding contacts. Oral health related quality of life was recorded using the 14 item Oral Health Impact Profile. Nutritional status was measured using the Mini Nutritional Assessment (MNA) in addition to biochemical analysis of a haematological sample. Correlation between data values was measured using a Pearson's correlation coefficient (r).

Results: The patient sample was made up of 44% males and 56% females with a mean age of 72.4 years (range 65-84 years). With increasing age the patients' oral health related quality of life scores improved. (r=-0.25) Within the sample the number of occluding tooth contacts ranged from 6 to 11. It was found that as the number of occluding contacts increased, better oral health related quality of life scores were recorded. (r=-0.30) Generally mini nutritional assessment scores improved with increasing numbers of tooth contacts. (r=0.14) In addition, as the number of occluding teeth contacts increased total lymphocyte count (r=0.35), vitamin B12 (r=0.22) and serum folate (r=0.06) all increased.

Conclusions: In older patients increased numbers of tooth contacts are associated with better oral health related quality of life. Increasing numbers of occluding contacts are also associated with better MNA scores and some haematological indicators of nutritional status.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The peptides derived from envelope proteins have been shown to inhibit the protein-protein interactions in the virus membrane fusion process and thus have a great potential to be developed into effective antiviral therapies. There are three types of envelope proteins each exhibiting distinct structure folds. Although the exact fusion mechanism remains elusive, it was suggested that the three classes of viral fusion proteins share a similar mechanism of membrane fusion. The common mechanism of action makes it possible to correlate the properties of self-derived peptide inhibitors with their activities. Here we developed a support vector machine model using sequence-based statistical scores of self-derived peptide inhibitors as input features to correlate with their activities. The model displayed 92% prediction accuracy with the Matthew’s correlation coefficient of 0.84, obviously superior to those using physicochemical properties and amino acid decomposition as input. The predictive support vector machine model for self- derived peptides of envelope proteins would be useful in development of antiviral peptide inhibitors targeting the virus fusion process.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Channel randomness can be exploited to generate secret keys. However, to ensure secrecy, it is necessary that the channel response of any eavesdropping party remain sufficiently de-correlated with that of the legitimate users'. In this paper, we investigate whether such de-correlation occurs for a body area network (BAN) operating in an indoor environment at 2.45 GHz. The hypothetical BAN configuration consisted of two legitimate transceivers, one situated on the user's left wrist and the other on the user's waist. The eavesdroppers were positioned in either a co-located or distributed manner in the area surrounding the BAN user. Using the simultaneous channel response measured at the legitimate BAN nodes and the eavesdropper positions for stationary and mobile scenarios, we analyze the localized correlation coefficient. This allows us to determine if it is possible to generate secret keys in the presence of multiple eavesdroppers in an indoor environment. Our experimental results show that although channel reciprocity was observed for both the stationary and the mobile scenarios, a higher de-correlation between the legitimate users' channels was observed for the stationary case. This indicates that mobile scenarios are better suited for secret key generation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mutual variation of the received signal which occurs as a consequence of the channel reciprocity property has recently been proposed as a viable method for secret key generation. However, this cannot be strictly maintained in practice as the property is applicable only in the absence of interference. To ensure the propagation defined key remains secret, one requirement is that there remain high degrees of uncertainty between the legitimate users channel response and that of any eavesdropper's. In this paper, we investigate whether such de-correlation occurs for an indoor point-to-point link at 2.45 GHz. This is achieved by computing the localized correlation coefficient between the simultaneous channel response measured by the legitimate users and that of multiple distributed eavesdroppers for static and dynamic scenarios.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The regulation of pulpal haemodynamics in health and disease involves sympathetic and parasympathetic mechanisms in which both neuropeptide Y (NPY; a sympathetic vasoconstrictor) and vasoactive intestinal polypeptide (VIP; a parasympathetic vasodilator) may play potential pathophysiological roles. We have previously investigated the levels of NPY or VIP present in human dental pulp tissue and shown that their expression is up-regulated in caries induced pulpal inflammation. Objectives: The aim of this study was to investigate the potential correlation between NPY and VIP levels measured in the same dental pulp samples using radioimmunoassay (RIA). Methods: Pulp tissue was obtained from extracted teeth, classified as follows; healthy (n=22), moderately carious (n=20) and grossly carious (n=26). Samples were processed for RIA by boiling in acetic acid as previously described. The levels of NPY and VIP, measured by RIA, were expressed as ng/gram of pulp tissue. The nature of the relationship between NPY and VIP levels in human pulp tissue was tested by calculating Pearson's product moment correlation coefficient using the linear regression test. Results: Calculation of Pearson product moment correlation coefficient showed a significant negative correlation between NPY and VIP levels in pulp tissue samples from non-carious teeth (p = 0.02, r = -.48). This negative correlation in non-carious teeth changed to a significant positive correlation in carious teeth when the levels of NPY and VIP were compared (p = 0.03, r= 0.311). Conclusions: In non-carious teeth, the negative correlation between NPY and VIP levels is in keeping with the previously described modulatory influence of cholinergic nerves on sympathetic function which may be perturbed as caries develops.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE:

To design a system of gonioscopy that will allow greater interobserver reliability and more clearly defined screening cutoffs for angle closure than current systems while being simple to teach and technologically appropriate for use in rural Asia, where the prevalence of angle-closure glaucoma is highest.

DESIGN:

Clinic-based validation and interobserver reliability trial.

PARTICIPANTS:

Study 1: 21 patients 18 years of age and older recruited from a university-based specialty glaucoma clinic; study 2: 32 patients 18 years of age and older recruited from the same clinic.

INTERVENTION:

In study 1, all participants underwent conventional gonioscopy by an experienced observer (GLS) using the Spaeth system and in the same eye also underwent Scheimpflug photography, ultrasonographic measurement of anterior chamber depth and axial length, automatic refraction, and biometric gonioscopy with measurement of the distance from iris insertion to Schwalbe's line using a reticule based in the slit-lamp ocular. In study 2, all participants underwent both conventional gonioscopy and biometric gonioscopy by an experienced gonioscopist (NGC) and a medical student with no previous training in gonioscopy (JK).

MAIN OUTCOME MEASURES:

Study 1: The association between biometric gonioscopy and conventional gonioscopy, Scheimpflug photography, and other factors known to correlate with the configuration of the angle. Study 2: Interobserver agreement using biometric gonioscopy compared to that obtained with conventional gonioscopy.

RESULTS:

In study 1, there was an independent, monotonic, statistically significant relationship between biometric gonioscopy and both Spaeth angle (P = 0.001, t test) and Spaeth insertion (P = 0.008, t test) grades. Biometric gonioscopy correctly identified six of six patients with occludable angles according to Spaeth criteria. Biometric gonioscopic grade was also significantly associated with the anterior chamber angle as measured by Scheimpflug photography (P = 0.005, t test). In study 2, the intraclass correlation coefficient between graders for biometric gonioscopy (0.97) was higher than for Spaeth angle grade (0.72) or Spaeth insertion grade (0.84).

CONCLUSION:

Biometric gonioscopy correlates well with other measures of the anterior chamber angle, shows a higher degree of interobserver reliability than conventional gonioscopy, and can readily be learned by an inexperienced observer.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To estimate the relationships between ocular parameters and tonometrically measured intraocular pressure (IOP), to determine the influence of ocular parameters on different instrument measurements of IOP, and to evaluate the association of ocular parameters with a parameter called hysteresis. METHODS: Patients presenting at a glaucoma clinic were recruited for this study. Subjects underwent IOP measurement with the Goldmann applanation tonometer (GAT), the TonoPen, and the Reichert Ocular Response Analyzer (ORA), and also measurements of central corneal thickness (CCT), axial length, corneal curvature, corneal astigmatism, central visual acuity, and refractive error. Chart information was reviewed to determine glaucoma treatment history. The ORA instrument provided a measurement called corneal hysteresis. The association between measured IOP and the other ocular characteristics was estimated using generalized estimating equations. RESULTS: Among 230 patients, IOP measurements from the TonoPen read lowest, and ORA read highest, and GAT measurements were closest to the mean IOP of the 3 instruments. In a multiple regression model adjusting for age, sex, race, and other ocular characteristics, a 10 microm increase in CCT was associated with an increase of 0.79 mm Hg measured IOP in untreated eyes (P<0.0001). Of the 3 tonometers, GAT was the least affected by CCT (0.66 mm Hg/10 mum, P<0.0001). Hysteresis was significantly correlated with CCT with a modest correlation coefficient (r=0.20, P<0.0007). CONCLUSIONS: Among parameters related to measured IOP, features in addition to CCT, such as hysteresis and corneal curvature, may also be important. Tonometric instruments seem to be affected differently by various physiologic characteristics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Low corneal hysteresis is associated with longer axial length in Chinese secondary school children. The authors sought to explore this association in primary school children. METHODS: LogMAR presenting visual acuity, cycloplegic refractive error, ocular biometry, central corneal thickness (CCT), and corneal hysteresis (CH) was assessed for children in grades 1 to 3 at an academically competitive urban school in Shantou, China. RESULTS: Among 872 eligible children (mean age, 8.6 ± 2.1 years), 651 (74.7%) completed the examination. Among 1299 examined eyes, 111 (8.5%) had uncorrected vision ≤6/12. Mean spherical equivalent refractive error for all eyes was +0.26 ± 1.41 D, and axial length (AL) was 22.7 ± 0.90 mm. CH for the lowest (mean AL, 21.7 ± 0.39 mm), two middle (mean AL, 22.4 ± 0.15 and 22.9 ± 0.15 mm), and highest quartiles (mean AL, 23.7 ± 0.74 mm) of AL were 10.6 ± 2.1 mm Hg, 10.4 ± 2.1 mm Hg, 10.3 ± 2.3 mm Hg, and 10.2 ± 2.3 mm Hg respectively (age- and gender-adjusted Pearson's correlation coefficient r = -0.052; P = 0.001). In generalized estimating equation models adjusting for age, gender, and CCT, lower CH was significantly associated with longer AL (P < 0.001) and more myopic refractive error (P = 0.001). CONCLUSIONS: CH measurement is practical in young children because this is when myopia undergoes its most rapid progression. Prospective follow-up of this cohort at high risk for myopia is under way to determine whether low CH is predictive, or a consequence, of long AL.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main objective of the study presented in this paper was to investigate the feasibility using support vector machines (SVM) for the prediction of the fresh properties of self-compacting concrete. The radial basis function (RBF) and polynomial kernels were used to predict these properties as a function of the content of mix components. The fresh properties were assessed with the slump flow, T50, T60, V-funnel time, Orimet time, and blocking ratio (L-box). The retention of these tests was also measured at 30 and 60 min after adding the first water. The water dosage varied from 188 to 208 L/m3, the dosage of superplasticiser (SP) from 3.8 to 5.8 kg/m3, and the volume of coarse aggregates from 220 to 360 L/m3. In total, twenty mixes were used to measure the fresh state properties with different mixture compositions. RBF kernel was more accurate compared to polynomial kernel based support vector machines with a root mean square error (RMSE) of 26.9 (correlation coefficient of R2 = 0.974) for slump flow prediction, a RMSE of 0.55 (R2 = 0.910) for T50 (s) prediction, a RMSE of 1.71 (R2 = 0.812) for T60 (s) prediction, a RMSE of 0.1517 (R2 = 0.990) for V-funnel time prediction, a RMSE of 3.99 (R2 = 0.976) for Orimet time prediction, and a RMSE of 0.042 (R2 = 0.988) for L-box ratio prediction, respectively. A sensitivity analysis was performed to evaluate the effects of the dosage of cement and limestone powder, the water content, the volumes of coarse aggregate and sand, the dosage of SP and the testing time on the predicted test responses. The analysis indicates that the proposed SVM RBF model can gain a high precision, which provides an alternative method for predicting the fresh properties of SCC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The ability to exchange keys between users is vital in any wireless based security system. A key generation technique which exploits the randomness of the wireless channel is a promising alternative to existing key distribution techniques, e.g., public key cryptography. In this paper, a secure key generation scheme based on the subcarriers' channel responses in orthogonal frequency-division multiplexing (OFDM) systems is proposed. We first implement a time-variant multipath channel with its channel impulse response modelled as a wide sense stationary (WSS) uncorrelated scattering random process and demonstrate that each subcarrier's channel response is also a WSS random process. We then define the X% coherence time as the time required to produce an X% correlation coefficient in the autocorrelation function (ACF) of each channel tap, and find that when all the channel taps have the same Doppler power spectrum, all subcarriers' channel responses has the same ACF as the channel taps. The subcarrier's channel response is then sampled every X% coherence time and quantized into key bits. All the key sequences' randomness is tested using National Institute of Standards and Technology (NIST) statistical test suite and the results indicate that the commonly used sampling interval as 50% coherence time cannot guarantee the randomness of the key sequence.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Sleep-disordered breathing is a common and serious feature of many paediatric conditions and is particularly a problem in children with Down syndrome. Overnight pulse oximetry is recommended as an initial screening test, but it is unclear how overnight oximetry results should be interpreted and how many nights should be recorded.

METHODS: This retrospective observational study evaluated night-to-night variation using statistical measures of repeatability for 214 children referred to a paediatric respiratory clinic, who required overnight oximetry measurements. This included 30 children with Down syndrome. We measured length of adequate trace, basal SpO2, number of desaturations (>4% SpO2 drop for >10 s) per hour ('adjusted index') and time with SpO2<90%. We classified oximetry traces into normal or abnormal based on physiology.

RESULTS: 132 out of 214 (62%) children had three technically adequate nights' oximetry, including 13 out of 30 (43%) children with Down syndrome. Intraclass correlation coefficient for adjusted index was 0.54 (95% CI 0.20 to 0.81) among children with Down syndrome and 0.88 (95% CI 0.84 to 0.91) for children with other diagnoses. Negative predictor value of a negative first night predicting two subsequent negative nights was 0.2 in children with Down syndrome and 0.55 in children with other diagnoses.

CONCLUSIONS: There is substantial night-to-night variation in overnight oximetry readings among children in all clinical groups undergoing overnight oximetry. This is a more pronounced problem in children with Down syndrome. Increasing the number of attempted nights' recording from one to three provides useful additional clinical information.