27 resultados para allochthonous input


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This output is a collection of compositions which explore issues of ensemble improvisation, ensemble management and orchestration, real-time and distributed scoring, multi-nodal inputs and outputs, and animated and graphic notation. Compositions include: Activities I; tutti, duet, trio, solo, quartet; Lewitt Notations I; Webwork I; and Sometimes I feel the space between people (voices) in terms of tempos. These compositions are presented in computer animated scores which are synchronized through the network and subject to real-time modification and control. They can be performed by ensembles distributed over large physical spaces connected by the network. The scores for these compositions include software which displays the animations to the performers, software to structure and disseminate score events, and triggering software that allows the control of a performance to be distributed. Scores can also include live electronics which are coordinated with graphic events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capillary-based systems for measuring the input impedance of musical wind instruments were first developed in the mid-20th century and remain in widespread use today. In this paper, the basic principles and assumptions underpinning the design of such systems are examined. Inexpensive modifications to a capillary-based impedance measurement set-up made possible due to advances in computing and data acquisition technology are discussed. The modified set-up is able to measure both impedance magnitude and impedance phase even though it only contains one microphone. In addition, a method of calibration is described that results in a significant improvement in accuracy when measuring high impedance objects on the modified capillary-based system. The method involves carrying out calibration measurements on two different objects whose impedances are well-known theoretically. The benefits of performing two calibration measurements (as opposed to the one calibration measurement that has been traditionally used) are demonstrated experimentally through input impedance measurements on two test objects and a Boosey and Hawkes oboe. © S. Hirzel Verlag · EAA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we propose a design methodology for low-power high-performance, process-variation tolerant architecture for arithmetic units. The novelty of our approach lies in the fact that possible delay failures due to process variations and/or voltage scaling are predicted in advance and addressed by employing an elastic clocking technique. The prediction mechanism exploits the dependence of delay of arithmetic units upon input data patterns and identifies specific inputs that activate the critical path. Under iso-yield conditions, the proposed design operates at a lower scaled down Vdd without any performance degradation, while it ensures a superlative yield under a design style employing nominal supply and transistor threshold voltage. Simulation results show power savings of upto 29%, energy per computation savings of upto 25.5% and yield enhancement of upto 11.1% compared to the conventional adders and multipliers implemented in the 70nm BPTM technology. We incorporated the proposed modules in the execution unit of a five stage DLX pipeline to measure performance using SPEC2000 benchmarks [9]. Maximum area and throughput penalty obtained were 10% and 3% respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increasingly semiconductor manufacturers are exploring opportunities for virtual metrology (VM) enabled process monitoring and control as a means of reducing non-value added metrology and achieving ever more demanding wafer fabrication tolerances. However, developing robust, reliable and interpretable VM models can be very challenging due to the highly correlated input space often associated with the underpinning data sets. A particularly pertinent example is etch rate prediction of plasma etch processes from multichannel optical emission spectroscopy data. This paper proposes a novel input-clustering based forward stepwise regression methodology for VM model building in such highly correlated input spaces. Max Separation Clustering (MSC) is employed as a pre-processing step to identify a reduced srt of well-conditioned, representative variables that can then be used as inputs to state-of-the-art model building techniques such as Forward Selection Regression (FSR), Ridge regression, LASSO and Forward Selection Ridge Regression (FCRR). The methodology is validated on a benchmark semiconductor plasma etch dataset and the results obtained are compared with those achieved when the state-of-art approaches are applied directly to the data without the MSC pre-processing step. Significant performance improvements are observed when MSC is combined with FSR (13%) and FSRR (8.5%), but not with Ridge Regression (-1%) or LASSO (-32%). The optimal VM results are obtained using the MSC-FSR and MSC-FSRR generated models. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Discrimination of different species in various target scopes within a single sensing platform can provide many advantages such as simplicity, rapidness, and cost effectiveness. Here we design a three-input colorimetric logic gate based on the aggregation and anti-aggregation of gold nanoparticles (Au NPs) for the sensing of melamine, cysteine, and Hg2+. The concept takes advantages of the highly specific coordination and ligand replacement reactions between melamine, cysteine, Hg2+, and Au NPs. Different outputs are obtained with the combinational inputs in the logic gates, which can serve as a reference to discriminate different analytes within a single sensing platform. Furthermore, besides the intrinsic sensitivity and selectivity of Au NPs to melamine-like compounds, the “INH” gates of melamine/cysteine and melamine/Hg2+ in this logic system can be employed for sensitive and selective detections of cysteine and Hg2+, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The non-covalent incorporation of responsive luminescent lanthanide, Ln(iii), complexes with orthogonal outputs from Eu(iii) and Tb(iii) in a gel matrix allows for in situ logic operation with colorimetric outputs. Herein, we report an exemplar system with two inputs ([H(+)] and [F(-)]) within a p(HEMA-co-MMA) polymer organogel acting as a dual-responsive device and identify future potential for such systems.