69 resultados para accelerometer accuracy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Towards a Revolution in COPD Health (TORCH) trial was an international clinical trial of chronic obstructive pulmonary disease (COPD) patients where cause of death was assigned by an independent committee. Comparison of death certificate data and adjudicated cause of death allows a unique opportunity to determine death certificate accuracy and frequency of COPD listing on death certificates of COPD patients. In this analysis, the authors determine the concordance between adjudicated cause of death and primary and secondary cause of death from death certificates. In 317 (80%) of informative deaths, the primary or secondary cause of death from certificates agreed with adjudicated cause of death. Only 229 (58%) of death certificates in these COPD patients listed COPD on the certificate. COPD was not listed on the death certificate in 21% of deaths adjudicated to be caused by COPD exacerbation. Compared with pulmonary causes, the listing of COPD on certificates occurred with less frequency than cardiovascular, cancer and other categories of death. The combined primary and secondary listing on death certificates has good concordance with actual cause of death. COPD is under-reported on death certificates, and this under-reporting is more frequent when the primary cause of death is not pulmonary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ambisonics and higher order ambisonics (HOA) technologies aim at reproducing sound field either synthesised or previously recorded with dedicated microphones. Based on a spherical harmonic decomposition, the sound field is more precisely described when higher-order components are used. The presented study evaluated the perceptual and objective localisation accuracy of the sound field encoded with four microphones of order one to four and decoded over a ring of loudspeakers. A perceptual test showed an improvement of the localisation with higher order ambisonic microphones. Reproduced localisation indices were estimated for the four microphones and the respective synthetic systems of order one to four. The perceptual and objective analysis revealed the same conclusions. The localisation accuracy depends on the ambisonic order as well as the source incidence. Furthermore, impairments linked to the microphones were highlighted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probebased real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here the protocol of the first systematic review of published clinical diagnostic accuracy studies of this technology when compared with blood culture in the setting of suspected sepsis. Methods/design: Data sources: the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), The Cochrane Library, MEDLINE, EMBASE, ISI Web of Science, BIOSIS Previews, MEDION and the Aggressive Research Intelligence Facility Database (ARIF). Study selection: diagnostic accuracy studies that compare the real-time PCR technology with standard culture results performed on a patient's blood sample during the management of sepsis. Data extraction: three reviewers, working independently, will determine the level of evidence, methodological quality and a standard data set relating to demographics and diagnostic accuracy metrics for each study. Statistical analysis/data synthesis: heterogeneity of studies will be investigated using a coupled forest plot of sensitivity and specificity and a scatter plot in Receiver Operator Characteristic (ROC) space. Bivariate model method will be used to estimate summary sensitivity and specificity. The authors will investigate reporting biases using funnel plots based on effective sample size and regression tests of asymmetry. Subgroup analyses are planned for adults, children and infection setting (hospital vs community) if sufficient data are uncovered. Dissemination: Recommendations will be made to the Department of Health (as part of an open-access HTA report) as to whether the real-time PCR technology has sufficient clinical diagnostic accuracy potential to move forward to efficacy testing during the provision of routine clinical care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nitrogen Dioxide (NO2) is known to act as an environmental trigger for many respiratory illnesses. As a pollutant it is difficult to map accurately, as concentrations can vary greatly over small distances. In this study three geostatistical techniques were compared, producing maps of NO2 concentrations in the United Kingdom (UK). The primary data source for each technique was NO2 point data, generated from background automatic monitoring and background diffusion tubes, which are analysed by different laboratories on behalf of local councils and authorities in the UK. The techniques used were simple kriging (SK), ordinary kriging (OK) and simple kriging with a locally varying mean (SKlm). SK and OK make use of the primary variable only. SKlm differs in that it utilises additional data to inform prediction, and hence potentially reduces uncertainty. The secondary data source was Oxides of Nitrogen (NOx) derived from dispersion modelling outputs, at 1km x 1km resolution for the UK. These data were used to define the locally varying mean in SKlm, using two regression approaches: (i) global regression (GR) and (ii) geographically weighted regression (GWR). Based upon summary statistics and cross-validation prediction errors, SKlm using GWR derived local means produced the most accurate predictions. Therefore, using GWR to inform SKlm was beneficial in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of microbeams is providing new insights into the actions of radiation at the cell and tissue levels. So far, this has been achieved exclusively through the use of collimated charged particles. One alternative is to use ultrasoft X rays, focused by X-ray diffractive optics. We have developed a unique facility that uses 0.2-0.8-mm-diameter zone plates to focus ultrasoft X rays to a beam of less than 1 mum diameter. The zone plate images characteristic K-shell X rays of carbon or aluminum, generated by focusing a beam of 5-10 keV electrons onto the appropriate target. By reflecting the X rays off a grazing-incidence mirror, the contaminating bremsstrahlung radiation is reduced to 2%. The focused X rays are then aimed at selected subcellular targets using rapid automated cell-finding and alignment procedures; up to 3000 cells per hour can be irradiated individually using this arrangement. (C) 2001 by Radiation Research Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevailing paradigm for researching sensorimotor synchronisation in humans involves finger tapping and temporal accuracy measures. However, many successful sensorimotor synchronisation actions require not only to be 'in time', but also to be in a predefined spatial position. Reaching this spatial position in many everyday actions often exceeds the average amplitude of a finger movement. The aim of this study is to address how people coordinate their movement to be in the right place at the right time when the scale of the movement varies. Does the scale of the movement and accuracy demands of the movement change the ability to accurately synchronise? To address these questions, a sensorimotor synchronisation task with three different inter-beat intervals, two different movement amplitudes and two different target widths was used. Our experiment demonstrated that people use different timing strategies-employing either a movement strategy (varying movement time) or a waiting strategy (keeping movement time constant) for large-scale movements. Those two strategies were found to be equally successful in terms of temporal accuracy and variability (spread of errors). With longer interval durations (2.5 and 3.5 s), variability of sensorimotor synchronisation performance increased (measured as the spread of errors). Analysing the data using the Vorberg and Wing (Handbook of perception and action. Academic Press, New York, pp 181-262, 1996) model shows a need to develop further existing timing models of sensorimotor synchronisation so that they could apply to large-scale movements, where different movement strategies naturally emerge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic accuracy and management recommendations of realtime teledermatology consultations using low-cost telemedicine equipment were evaluated. Patients were seen by a dermatologist over a video-link and a diagnosis and treatment plan were recorded. This was followed by a face-to-face consultation on the same day to confirm the earlier diagnosis and management plan. A total of 351 patients with 427 diagnoses participated. Sixty-seven per cent of the diagnoses made over the video-link agreed with the face-to-face diagnosis. Clinical management plans were recorded for 214 patients with 252 diagnoses. For this cohort, 44% of the patients were seen by the same dermatologist at both consultations, while 56% were seen by a different dermatologist. In 64% of cases the same management plan was recommended at both consultations; a sub-optimum treatment plan was recommended in 8% of cases; and in 9% of cases the video-link management plans were judged to be inappropriate. In 20% of cases the dermatologist was unable to recommend a suitable management plan by video-link. There were significant differences in the ability to recommend an optimum management plan by video-link when a different dermatologist made the reference management plan. The results indicate that a high proportion of dermatological conditions can be successfully managed by realtime teledermatology.