151 resultados para Wrapper validation
Resumo:
This article describes the development of SPE and HPLC methods for the simultaneous determination of metformin and glipizide, gliclazide, glibenclamide or glimperide in plasma. Several extraction and HPLC methods have been described previously for the determination of each of these analytes in plasma separately. The simultaneous determination of these analytes is important for the routine monitoring of diabetic patients who take combination medications and for studying the pharmacokinetics of the combined dosage forms. In addition this developed method can serve as a standard method for the plasma determination of these analytes therefore saving time, effort and money. The recoveries of the developed methods were found to be between 76.3% and 101.9%. The limits of quantification were between 5 and 22.5 ng/ml. The intraday and interday precision (measured by coefficient of variation, CV%) was always less than 9%. The accuracy (measured by relative error %) was always less than 12%. Stability analysis showed that all analytes are stable for at least 3 months when stored at -70degreesC. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Concentrations of the coccidiostat nicarbazin as low as 2 mg/kg in feed can result in violative drug residues arising in poultry liver. A lateral flow device (LFD) was developed for the detection of contaminating concentrations of nicarbazin following solvent extraction of poultry feeds. Test results, as determined by both visual and instrumental measurement, are available within minutes. For 22 feed samples, nicarbazin-free and fortified at 2 mg/kg, the % relative inhibition ranged from 0 to 45% and from 53 to 85%, respectively. Nicarbazin contamination at the critical concentration (2 mg/kg) can be determined in all cases providing the sampling is representative. A wide range of feed samples taken at a mill that incorporated nicarbazin into poultry feed were analyzed. Data generated for these samples by both the LFDs and a mass spectrometric method were compared, and a significant correlation was achieved.
Resumo:
The use of cortisol levels as a measure of stress is often complicated by the use of invasive techniques that may increase hypothalamic-pituitary-adrenal (HPA) axis activity during sample collection. The goal of this study was to collect samples noninvasively and validate an enzyme-immunoassay (EIA) for the measurement of cortisol in urine to quantify HPA axis activity in the bearded emperor tamarin (Saguinus imperator subgrisescens). Urine samples were collected from trained subjects between 0700 and 0730 hr during a 1-month period, and were pooled for immunological validation. We validated the assay immunologically by demonstrating specificity, accuracy, precision, and sensitivity. For biological validation of the assay, we showed that levels of urinary cortisol (in samples collected between 0700 and 1700 hr) varied significantly across the day. Cortisol concentration was lowest at 0700 hr, increased to a mid-morning peak (0900 hr), and declined across the remainder of the day in a typical mammalian circadian pattern. We thus demonstrate that urinary cortisol can be used to quantify HPA activity in S. i. subgrisescens. (C) 2004 Wiley-Liss, Inc.
Resumo:
An HPLC method has been developed and validated for the rapid determination of mercaptopurine and four of its metabolites; thioguanine, thiouric acid, thioxanthine and methylmercaptopurine in plasma and red blood cells. The method involves a simple treatment procedure based on deproteinisation by perchloric acid followed by acid hydrolysis and heating for 45 min at 100 degrees C. The developed method was linear over the concentration range studied with a correlation coefficient >0.994 for all compounds in both plasma and erythrocytes. The lower limits of quantification were 13, 14, 3, 2, 95 pmol/8 x 101 RBCs and 2, 5, 2, 3, 20 ng/ml plasma for thioguanine, thiouric acid, mercaptopurine, thioxanthine and methylmercaptopurine, respectively. The method described is selective and sensitive enough to analyse the different metabolites in a single run under isocratic conditions. Furthermore, it has been shown to be applicable for monitoring these metabolites in paediatric patients due to the low volume requirement (200 mu l of plasma or erythrocytes) and has been successfully applied for investigating population pharmacokinetics, pharmacogenetics and non-adherence to therapy in these patients. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
This study tested the psychometric properties of a questionnaire that measured sources of distress and eustress, or good stress, in nursing students. The Transactional model of stress construes stress in these different ways and is frequently used to understand sources of stress, coping and stress responses. Limited research has attempted to measure sources of distress and eustress or sources that can potentially enhance performance and well-being. A volunteer sample of final year nursing students (n = 120) was surveyed in the United Kingdom in 2007. The questionnaire measured sources of stress and measures of psychological well-being were taken to test construct validity. This was tested through an exploratory factor analysis. This reduced the questionnaire from 49 to 29 items and suggested three factors: learning and teaching, placement related and course organization; second, it was analysed by testing the assumptions of the Transactional model, the model on which the questionnaire was based. In line with the assumptions of the model, measures of distress related to adverse well-being, and measures of eustress related to healthier well-being responses. The test–retest reliability estimate was 0.8. While certain programme issues were associated with distress, placement-related experiences were the most important source of eustress.