23 resultados para Voltammetric behaviors
Resumo:
The operant learning theory account of behaviors of clinical significance in people with intellectual disability (ID) has dominated the field for nearly 50 years. However, in the last two decades, there has been a substantial increase in published research that describes the behavioral phenotypes of genetic disorders and shows that behaviors such as self-injury and aggression are more common in some syndromes than might be expected given group characteristics. These cross-syndrome differences in prevalence warrant explanation, not least because this observation challenges an exclusively operant learning theory account. To explore this possible conflict between theoretical account and empirical observation, we describe the genetic cause and physical, social, cognitive and behavioral phenotypes of four disorders associated with ID (Angleman, Cornelia de Lange, Prader-Willi and Smith-Magenis syndromes) and focus on the behaviors of clinical significance in each syndrome. For each syndrome we then describe a model of the interactions between physical characteristics, cognitive and motivational endophenotypes and environmental factors (including operant reinforcement) to account for the resultant behavioral phenotype. In each syndrome it is possible to identify pathways from gene to physical phenotype to cognitive or motivational endophenotype to behavior to environment and back to behavior. We identify the implications of these models for responsive and early intervention and the challenges for research in this area. We identify a pressing need for meaningful dialog between different disciplines to construct better informed models that can incorporate all relevant and robust empirical evidence.
Resumo:
The negative impact of political violence on adolescent adjustment is well established. Less is known about factors that affect adolescents' positive outcomes in ethnically divided societies, especially influences on prosocial behaviors toward the out-group, which may promote constructive relations. For example, understanding how inter-group experiences and attitudes motivate out-group helping may foster inter-group co-operation and help to consolidate peace. The current study investigated adolescents' overall and out-group prosocial behaviors across two time points in Belfast, Northern Ireland (N = 714 dyads; 49% male; Time 1: M = 14.7, SD = 2.0, years old). Controlling for Time 1 prosocial behaviors, age, and gender, multi-variate structural equation modeling showed that experience with inter-group sectarian threat predicted fewer out-group prosocial behaviors at Time 2 at the trend level. On the other hand, greater experience of intra-group non-sectarian threat at Time 1 predicted more overall and out-group prosocial behaviors at Time 2. Moreover, positive out-group attitudes strengthened the link between intra-group threat and out-group prosocial behaviors one year later. Finally, experience with intra-group non-sectarian threat and out-group prosocial behaviors at Time 1 was related to more positive out-group attitudes at Time 2. The implications for youth development and inter-group relations in post-accord societies are discussed.
Resumo:
Bias-induced oxygen ion dynamics underpins a broad spectrum of electroresistive and memristive phenomena in oxide materials. Although widely studied by device-level and local voltage-current spectroscopies, the relationship between electroresistive phenomena, local electrochemical behaviors, and microstructures remains elusive. Here, the interplay between history-dependent electronic transport and electrochemical phenomena in a NiO single crystalline thin film with a number of well-defined defect types is explored on the nanometer scale using an atomic force microscopy-based technique. A variety of electrochemically-active regions were observed and spatially resolved relationship between the electronic and electrochemical phenomena was revealed. The regions with pronounced electroresistive activity were further correlated with defects identified by scanning transmission electron microscopy. Using fully coupled mechanical-electrochemical modeling, we illustrate that the spatial distribution of strain plays an important role in electrochemical and electroresistive phenomena. These studies illustrate an approach for simultaneous mapping of the electronic and ionic transport on a single defective structure level such as dislocations or interfaces, and pave the way for creating libraries of defect-specific electrochemical responses.
Resumo:
This paper presents a novel hand-held instrument capable of real-time in situ detection and identification of heavy metals. The proposed system provides the facilities found in a traditional lab-based instrument in a hand held a design. In contrast to existing commercial systems, it can stand alone without the need of an associated computer. The electrochemical instrument uses anodic stripping voltammetry which is a precise and sensitive analytical method with excellent limits of detection. The sensors comprise disposable screen-printed (solid working) electrodes rather than the more common hanging mercury drop electrodes. The system is reliable, easy to use, safe, avoids expensive and time-consuming procedures and may be used in a variety of situations to help in the fields of environmental assessment and control.
Resumo:
This paper presents a portable electrochemical instrument capable of detecting and identifying heavy metals in soil, in situ. The instrument has been developed for use in a variety of situations to facilitate contaminated land surveys, avoiding expensive and time-consuming procedures. The system uses differential pulse anodic stripping voltammetry which is a precise and sensitive analytical method with excellent limits of detection. The identification of metals is based on a statistical microprocessor-based method. The instrument is capable of detecting six different toxic metals (lead, cadmium, zinc, nickel, mercury and copper) with good sensitivity
Resumo:
The use of anodic stripping voltammetry (ASV)has been proven in the past to be a precise and sensitive analytical method with an excellent limit of detection. Electrochemical sensors could help to avoid expensive and time consuming procedures as sample taking and storage and provide a both sensitive and reliable method for the direct monitoring of heavy metals in the aquatic environment. Solid electrodes which have been used in this work, were produced using previously developed methods. Commercially available and newly designed, screen printed carbon and gold plated working electrodes (WE) were compared. Good results were achieved with the screen printed and plated electrodes under conditions optimized for each electrode material. The electrode stability, reproducibility of single measurements and the limit of detection obtained for Pb were satisfactory (3*10-6mol/l on screen printed carbon WEs after 60 s of deposition and 6*10-6 mol/l on gold plated WEs after 5 min of deposition). Complete 3-electrode-sets (counter, reference and working electrode) were screen printed on different substrates (glass, polycarbonate and alumina). Also here, both carbon and gold were used as WE. Using 3-electrode-sets with a gold plated WE on glass was a limit of detection of 7*10-7 mol/l was achieved after only 60 s of deposition.
Resumo:
In order to investigate the compatibility of candidate structural materials with liquid metals, two kinds of ferritic/martensitic steels were chosen to contact with lead–bismuth eutectic in sealed quartz–glass tubes. The corrosion exposures were for 500 and 3000 h. Results showed that the oxidation layer and carbide dissolution layer on the two steels grew with contact time under oxygen unsaturated condition. Short-term corrosion behavior of a newly developed steel showed better lead–bismuth eutectic corrosion resistance than T91 at 873 K.
Resumo:
In order to assess the susceptibility of candidate structural materials to liquid metal embrittlement, this work investigated the tensile behaviors of ferritic-martensitic steel in static lead bismuth eutectic (LBE). The tensile tests were carried out in static lead bismuth eutectic under different temperatures and strain rates. Pronounced liquid metal embrittlement phenomenon is observed between 200 °C and 450 °C. Total elongation is reduced greatly due to the liquid metal embrittlement in LBE environment. The range of ductility trough is larger under slow strain rate tensile (SSRT) test.