65 resultados para Viscosity and digestion
Resumo:
The article highlights new insights into production of thin titania films widely used as catalyst support in many modern reactors including capillary microreactors, microstructured fixed-bed reactors and falling film microreactors. Dip-coating of a Mania sol onto a Si substrate has been studied in the range of the sol viscosities of 1.5-2.5 mPa s and the sol withdrawal rates of 0.2-18 mm/s. Different viscosities of sols were created by addition of desired amounts of nitric acid to the synthesis mixture of titanium isopropoxide and Plutonic F127 in ethanol which allowed to control the rate of the condensation reactions. Uniform inesoporous titania coatings were obtained at the solvent withdrawal rates below 10 mm/s at sol viscosities in the range from 1.6 mPa s to 2.5 mPa s. There exists a limiting withdrawal rate corresponding to a capillary number of ca. 0.01 beyond which uniform titania films cannot be obtained. Below the limiting withdrawal rate, the coating thickness is a power function of the sol viscosity and withdrawal rate, both with an exponent of 2/3. The limiting withdrawal rate increases as the solvent evaporation rate increases and it decreases as the sol viscosity increases. Crown Copyright (C) 2011 Published by Elsevier B.V. All rights reserved.
Resumo:
Dynamic mechanical analysis (DMA) is an analytical technique in which an oscillating stress is applied to a sample and the resultant strain measured as functions of both oscillatory frequency and temperature. From this, a comprehensive knowledge of the relationships between the various viscoelastic parameters, e.g. storage and loss moduli, mechanical damping parameter (tan delta), dynamic viscosity, and temperature may be obtained. An introduction to the theory of DMA and pharmaceutical and biomedical examples of the use of this technique are presented in this concise review. In particular, examples are described in which DMA has been employed to quantify the storage and loss moduli of polymers, polymer damping properties, glass transition temperature(s), rate and extent of curing of polymer systems, polymer-polymer compatibility and identification of sol-gel transitions. Furthermore, future applications of the technique for the optimisation of the formulation of pharmaceutical and biomedical systems are discussed. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
Novel mucoadhesive formulations containing hydroxyethylcellulose (HEC; 3 and 5%, w/w) or Carbopol (3 and 5%, w/w), polycarbophil (PC; 1 and 3%, w/w) and metronidazole (5%, w/w) at pH 6.8 were designed for the treatment of periodontal diseases. Each formulation was characterised in terms of hardness, compressibility, adhesiveness and cohesiveness (using Texture Profile Analysis), drug release, adhesion to a mucin disc (measured as a detachment force using the texture analyser in tensile mode) and, finally, syringeability (using the texture analyser in compression mode). Drug release from all formulations was non-diffusion controlled. Drug release was significantly decreased as the concentration of each polymeric component was increased, due to both the concomitant increased viscosity of the formulations and, additionally, the swelling kinetics of PC following contact with dissolution fluid. Increasing the concentrations of each polymeric component significantly increased formulation hardness, compressibility, adhesiveness, mucoadhesion and syringeability, yet decreased cohesiveness. Increased product hardness, compressibility and syringeability were due to polymeric effects on formulation viscosity. The effects on cohesiveness may be explained both by increased viscosity and also by the increasing semi-solid nature of products containing 5% HEC or Carbopol and PC (1 or 3%). The observations concerning formulation adhesiveness/mucoadhesion illustrate the adhesive nature of each polymeric component. Greatest adhesion was noted in formulations where neutralisation of PC was maximally suppressed. For the most part, increased time of contact between formulation and mucin significantly increased the required force of detachment, due to the greater extent of mucin polymer hydration and interpenetration with the formulations. Significant statistical interactions were observed between the effects of each polymer on drug release and mechanical/mucoadhesive properties. These interactions may be explained by formulatory effects on the extent of swelling of PC. In conclusion, the formulations described offered a wide range of mechanical and drug release characteristics. Formulations containing HEC exhibited superior physical characteristics for improved drug delivery to the periodontal pocket and are now the subject of long-term clinical investigations. (C) 1997 Elsevier Science B.V.
Resumo:
The introduction of perfluorocarbons (PFCs) and, more recently, semifluorinated alkanes (SFAs) has greatly facilitated vitreoretinal surgery. A distinction is made between the use of these substances as intraoperative tools and internal tamponade agents. This article reviews the physical and chemical properties of PFCs and SFAs and discusses the indications, results, and complications. The effectiveness of these substances as internal tamponade agents is discussed with reference to the specific gravity, contact angle, viscosity and ability to fill model eye chambers and the vitreous cavity. The evidence for the toxicity in animal and human is examined. Copyright (C) 2000 by W.B. Saunders Company.
Resumo:
Systematic experiments have been carried out on the thermal and rheological behaviour of the ionic liquid, 1-butyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl} imide, [C(4)mim][NTf2], and, for the first time, on the forced convective heat transfer of an ionic liquid under the laminar flow conditions. The results show that the thermal conductivity of the ionic liquid is similar to 0.13 W m(-1) K-1, which is almost independent of temperature between 25 and 40 degrees C. Rheological measurements show that the [C(4)mim][NTf2] liquid is a Newtonian fluid with its shear viscosity decreasing with increasing temperature according to the exponential law over a temperature range of 20-90 degrees C. The convective heat transfer experiments demonstrate that the thermal entrance length of the ionic liquid is very large due to its high viscosity and low thermal conductivity. The convective heat transfer coefficient is observed to be much lower than that of distilled water under the same conditions. The convective heat transfer data are also found to fit well to the convectional Shah's equation under the conditions of this work. (C) 2007 Elsevier Inc. All rights reserved.
Resumo:
We report here the first systematic study of the effect of impurities and additives (e.g., water, chloride, and cosolvents) on the physical properties of room-temperature ionic liquids. Remarkably, it was discovered that the viscosity of mixtures was dependent mainly on the mole fraction of added molecular solvents and only to a lesser extent upon their identity, allowing viscosity changes during the course of a reaction to be entirely predictable. While the addition of such molecular solvents decreases the viscosity and density, chloride impurities, arising from the preparation of the ionic liquids, increase viscosity dramatically. The commonly used methods of preparation were validated with respect to chloride impurity.
Resumo:
Optically active S-alkyl-N, N'-bis((S)-1-phenylethyl) thiouronium salts, abbreviated as (S)-[Cnpetu] Y (where Y is an anion; n = 1, 2, 3, 4, 6, 8, 10, 12 or 16), have been prepared and studied by a broad spectrum of analyses. This consists of density, viscosity, and conductivity determination, followed by a discussion of relevant correlations. Unusual trends depending on the S-alkyl chain length were documented for (S)-[Cnpetu][ NTf2] series (where [NTf2] = bis{(trifluoromethyl) sulfonyl} amide), including the viscosity decreasing with increasing chain length, and the conductivity showing a maximum between the S-butyl and the S-hexyl derivative. In addition, a hindered rotamerism of the thiouronium cation in dmso-d(6) solution was recognised by H-1 and C-13 NMR techniques. Thorough analysis of NMR spectra confirmed that the main contribution comes from rotation about the partial double C-S bond. For the first time, a neat thiouronium ionic liquid system has been subjected to quantitative analysis of hindered rotamerism by dynamic NMR coalescence studies, with estimated activation energy for rotation of 63.9 +/- 0.4 kJ mol(-1). Finally, the application of (S)-[C(n)petu] Y salts as chiral discriminating agents for carboxylates by 1H NMR spectroscopy was further investigated, demonstrating the influence of the S-alkyl chain length on chiral recognition; (S)-[C(2)petu][NTf2] ionic liquid with the mandelate anion gave the best results.
Resumo:
Viscosity represents a key indicator of product quality in polymer extrusion but has traditionally been difficult to measure in-process in real-time. An innovative, yet simple, solution to this problem is proposed by a Prediction-Feedback observer mechanism. A `Prediction' model based on the operating conditions generates an open-loop estimate of the melt viscosity; this estimate is used as an input to a second, `Feedback' model to predict the pressure of the system. The pressure value is compared to the actual measured melt pressure and the error used to correct the viscosity estimate. The Prediction model captures the relationship between the operating conditions and the resulting melt viscosity and as such describes the specific material behavior. The Feedback model on the other hand describes the fundamental physical relationship between viscosity and extruder pressure and is a function of the machine geometry. The resulting system yields viscosity estimates within 1% error, shows excellent disturbance rejection properties and can be directly applied to model-based control. This is of major significance to achieving higher quality and reducing waste and set-up times in the polymer extrusion industry.
Resumo:
The aim of this paper is to develop a new extruder control system for recycled materials which has ability to automatically maintain constant a polymer melt viscosity of mixed recycled polymers during extrusion, regardless of variations in the Melt Flow Index (MFI) of recycled mixed grade high density polyethylene (HDPE) feedstock. A closed-loop controller is developed to automatically regulate screw speed and barrel temperature profile to achieve constant viscosity and enable consistent processing of variable grade recycled HDPE materials. The experimental results of real time viscosity measurement and control using a 38mm single screw extruder with different recycled HDPEs with widely different MFIs are reported in this work
Resumo:
Given the growing interest in thermal processing methods, this study describes the use of an advanced rheological technique, capillary rheometry, to accurately determine the thermorheological properties of two pharmaceutical polymers, Eudragit E100 (E100) and hydroxypropylcellulose JF (HPC) and their blends, both in the presence and absence of a model therapeutic agent (quinine, as the base and hydrochloride salt). Furthermore, the glass transition temperatures (Tg) of the cooled extrudates produced using capillary rheometry were characterised using Dynamic Mechanical Thermal Analysis (DMTA) thereby enabling correlations to be drawn between the information derived from capillary rheometry and the glass transition properties of the extrudates. The shear viscosities of E100 and HPC (and their blends) decreased as functions of increasing temperature and shear rates, with the shear viscosity of E100 being significantly greater than that of HPC at all temperatures and shear rates. All platforms were readily processed at shear rates relevant to extrusion (approximately 200–300 s−1) and injection moulding (approximately 900 s−1). Quinine base was observed to lower the shear viscosities of E100 and E100/HPC blends during processing and the Tg of extrudates, indicative of plasticisation at processing temperatures and when cooled (i.e. in the solid state). Quinine hydrochloride (20% w/w) increased the shear viscosities of E100 and HPC and their blends during processing and did not affect the Tg of the parent polymer. However, the shear viscosities of these systems were not prohibitive to processing at shear rates relevant to extrusion and injection moulding. As the ratio of E100:HPC increased within the polymer blends the effects of quinine base on the lowering of both shear viscosity and Tg of the polymer blends increased, reflecting the greater solubility of quinine within E100. In conclusion, this study has highlighted the importance of capillary rheometry in identifying processing conditions, polymer miscibility and plasticisation phenomena.
Resumo:
Engineered cocrystals offer an alternative solid drug form with tailored physicochemical properties. Interestingly, although cocrystals provide many new possibilities, they also present new challenges, particularly in regard to their design and large-scale manufacture. Current literature has primarily focused on the preparation and characterization of novel cocrystals typically containing only the drug and coformer, leaving the subsequent formulation less explored. In this paper we propose, for the first time, the use of hot melt extrusion for the mechanochemical synthesis of pharmaceutical cocrystals in the presence of a meltable binder. In this approach, we examine excipients that are amenable to hot melt extrusion, forming a suspension of cocrystal particulates embedded in a pharmaceutical matrix. Using ibuprofen and isonicotinamide as a model cocrystal reagent pair, formulations extruded with a small molecular matrix carrier (xylitol) were examined to be intimate mixtures wherein the newly formed cocrystal particulates were physically suspended in a matrix. With respect to formulations extruded using polymeric carriers (Soluplus and Eudragit EPO, respectively), however, there was no evidence within PXRD patterns of either crystalline ibuprofen or the cocrystal. Importantly, it was established in this study that an appropriate carrier for a cocrystal reagent pair during HME processing should satisfy certain criteria including limited interaction with parent reagents and cocrystal product, processing temperature sufficiently lower than the onset of cocrystal Tm, low melt viscosity, and rapid solidification upon cooling.
Resumo:
During this work, a novel series of hydrophobic room temperature ionic liquids (ILs) based on five ether functionalized sulfonium cations bearing the bis(trifluoromethyl)sulfonylimide, [NTf2]- anion were synthesized and characterized. Their physicochemical properties, such as density, viscosity and ionic conductivity, electrochemical window along with thermal properties including phase transition behavior and decomposition temperature, have been measured. All of these ILs showed large liquid range temperature, low viscosity and good conductivity. Additionally, by combining DFT calculations along with electrochemical characterization it appears that these novel ILs show good electrochemical stability windows, suitable for the potential application as electrolyte materials in electrochemical energy storage devices.
Resumo:
Reduced arterial compliance precedes changes in blood pressure, which may be mediated through alterations in vessel wall matrix composition. We investigated the effect of the collagen type I-1 gene (COL1A1) +2046G>T polymorphism on arterial compliance in healthy individuals. We recruited 489 subjects (251 men and 238 women; mean age, 22.6±1.6 years). COL1A1 genotypes were determined using polymerase chain reaction and digestion by restriction enzyme Bal1. Arterial pulse wave velocities were measured in 3 segments, aortoiliac (PWVA), aortoradial (PWVB), and aorto-dorsalis-pedis (PWVF), as an index of compliance using a noninvasive optical method. Data were available for 455 subjects. The sample was in Hardy-Weinberg equilibrium with genotype distributions and allele frequencies that were not significantly different from those reported previously. The T allele frequency was 0.22 (95% confidence interval, 0.19 to 0.24). Two hundred eighty-three (62.2%) subjects were genotype GG, 148 (35.5%) subjects were genotype GT, and 24 (5.3%) subjects were genotype TT. A comparison of GG homozygotes with GT and TT individuals demonstrated a statistically significant association with arterial compliance: PWVF 4.92±0.03 versus 5.06±0.05 m/s (ANOVA, P=0.009), PWVB 4.20±0.03 versus 4.32±0.04 m/s (ANOVA, P=0.036), and PWVA 3.07±0.03 versus 3.15±0.03 m/s (ANOVA, P=0.045). The effects of genotype were independent of age, gender, smoking, mean arterial pressure, body mass index, family history of hypertension, and activity scores. We report an association between the COL1A1 gene polymorphism and arterial compliance. Alterations in arterial collagen type 1A deposition may play a role in the regulation of arterial compliance
Resumo:
Polymer extrusion is a complex process and the availability of good dynamic models is key for improved system operation. Previous modelling attempts have failed adequately to capture the non-linearities of the process or prove too complex for control applications. This work presents a novel approach to the problem by the modelling of extrusion viscosity and pressure, adopting a grey box modelling technique that combines mechanistic knowledge with empirical data using a genetic algorithm approach. The models are shown to outperform those of a much higher order generated by a conventional black box technique while providing insight into the underlying processes at work within the extruder.
Resumo:
An electronically polarizable model has been developed for the ionic liquid 1-ethyl-3-methylimidazolium nitrate (EMIM+/NO3-), Molecular dynamics simulation studies were then performed on both the polarizable and nonpolarizable versions of the model. Comparisons of shear viscosity and diffusion constants at 400 K show that the effects of polarizability are quite substantial and the polarizable model results are in better agreement with the experimental values.