393 resultados para Vincent Ferrer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Prevention of cardiovascular disease and heart failure (HF) in a cost-effective manner is a public health goal. This work aims to assess the cost-effectiveness of the St Vincent's Screening TO Prevent Heart Failure (STOP-HF) intervention.

METHODS AND RESULTS: This is a substudy of 1054 participants with cardiovascular risk factors [median age 65.8 years, interquartile range (IQR) 57.8:72.4, with 4.3 years, IQR 3.4:5.2, follow-up]. Annual natriuretic peptide-based screening was performed, with collaborative cardiovascular care between specialist physicians and general practitioners provided to patients with BNP levels >50 pg/mL. Analysis of cost per case prevented and cost-effectiveness per quality-adjusted life year (QALY) gained was performed. The primary clinical endpoint of LV dysfunction (LVD) with or without HF was reduced in intervention patients [odds ratio (OR) 0.60; 95% confidence interval (CI) 0.38-0.94; P = 0.026]. There were 157 deaths and/or emergency hospitalizations for major adverse cardiac events (MACE) in the control group vs. 102 in the intervention group (OR 0.68; 95% CI 0.49-0.93; P = 0.01). The cost per case of LVD/HF prevented was €9683 (sensitivity range -€843 to €20 210), whereas the cost per MACE prevented was €3471 (sensitivity range -€302 to €7245). Cardiovascular hospitalization savings offset increased outpatient and primary care costs. The cost per QALY gain was €1104 and the intervention has an 88% probability of being cost-effective at a willingness to pay threshold of €30 000.

CONCLUSION: Among patients with cardiovascular risk factors, natriuretic peptide-based screening and collaborative care reduced LVD, HF, and MACE, and has a high probability of being cost-effective.

TRIAL REGISTRATION: NCT00921960.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Limited data are available concerning the evolution of the left atrial volume index (LAVI) in pre-heart failure (HF) patients. The aim of this study was to investigate clinical characteristics and serological biomarkers in a cohort with risk factors for HF and evidence of serial atrial dilatation.

METHODS AND RESULTS: This was a prospective substudy within the framework of the STOP-HF cohort (NCT00921960) involving 518 patients with risk factors for HF electively undergoing serial clinical, echocardiographic, and natriuretic peptide assessment. Mean follow-up time between assessments was 15 ± 6 months. 'Progressors' (n = 39) were defined as those with serial LAVI change ≥3.5 mL/m(2) (and baseline LAVI between 20 and 34 mL/m(2)). This cut-off was derived from a calculated reference change value above the biological, analytical, and observer variability of serial LAVI measurement. Multivariate analysis identified significant baseline clinical associates of LAVI progression as increased age, beta-blocker usage, and left ventricular mass index (all P < 0.05). Serological biomarkers were measured in a randomly selected subcohort of 30 'Progressors' matched to 30 'Non-progressors'. For 'Progressors', relative changes in matrix metalloproteinase 9 (MMP9), tissue inhibitor of metalloproteinase 1 (TIMP1), and the TIMP1/MMP9 ratio, markers of interstitial remodelling, tracked with changes in LAVI over time (all P < 0.05).

CONCLUSION: Accelerated LAVI increase was found to occur in up to 14% of all pre-HF patients undergoing serial echocardiograms over a relatively short follow-up period. In a randomly selected subcohort of 'Progressors', changes in LAVI were closely linked with alterations in MMP9, TIMP1, and the ratio of these enzymes, a potential aid in highlighting this at-risk group.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oxaliplatin, an effective cytotoxic treatment in combination with 5-fluorouracil for colorectal cancer, is associated with sensory, motor and autonomic neurotoxicity. Motor symptoms include hyperexcitability while autonomic effects include urinary retention, but the cause of these side-effects is unknown. We examined the effects on motor nerve function in the mouse hemidiaphragm and on the autonomic system in the vas deferens. In the mouse diaphragm, oxaliplatin (0.5 mM) induced multiple endplate potentials (EPPs) following a single stimulus, and was associated with an increase in spontaneous miniature EPP frequency. In the vas deferens, spontaneous excitatory junction potential frequency was increased after 30 min exposure to oxaliplatin; no changes in resting Ca(2+) concentration in nerve terminal varicosities were observed, and recovery after stimuli trains was unaffected.In both tissues, an oxaliplatin-induced increase in spontaneous activity was prevented by the voltage-gated Na(+) channel blocker tetrodotoxin (TTX). Carbamazepine (0.3 mM) also prevented multiple EPPs and the increase in spontaneous activity in both tissues. In diaphragm, beta-pompilidotoxin (100 microM), which slows Na(+) channel inactivation, induced multiple EPPs similar to oxaliplatin's effect. By contrast, blockers of K(+) channels (4-aminopyridine and apamin) did not replicate oxaliplatin-induced hyperexcitability in the diaphragm. The prevention of hyperexcitability by TTX blockade implies that oxaliplatin acts on nerve conduction rather than by effecting repolarisation. The similarity between beta-pompilidotoxin and oxaliplatin suggests that alteration of voltage-gated Na(+) channel kinetics is likely to underlie the acute neurotoxic actions of oxaliplatin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Channelled waves in 2-D periodic anisotropic L-C mesh metamaterials have been investigated. Circuit simulation and the newly developed analytical model of a unit cell have demonstrated full qualitative agreement for both lossless and lossy cases. Isofrequencies for a lattice unit cell and the circuit simulations of finite meshes have shown that propagating waves are channelled from a point source as pencil beams which can travel only along specific trajectories. The beam direction varies with frequency, and at the resonance frequency, the phase and group velocities of the travelling wave are orthogonal. The effect of losses was explored, and it was shown that losses cause qualitative changes of the channelled wave type. It was proven that the channelled waves do not follow the laws of geometrical optics (Snell's law, specular reflection, etc.) at the interfaces of L-C meshes but are governed by the conditions of phase synchronism and impedance matching. Only in the special case of dual L-C and C-L meshes with the interface parallel to the axis of rectangular grid excited at the resonance frequency (X=1) do the channels follow the trajectories of optical rays. A planar mesh test cell has been designed and used for retrieving the unit cell L-C parameters from the S-parameter measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this theoretical paper, the analysis of the effect that ON-state active-device resistance has on the performance of a Class-E tuned power amplifier using a shunt inductor topology is presented. The work is focused on the relatively unexplored area of design facilitation of Class-E tuned amplifiers where intrinsically low-output-capacitance monolithic microwave integrated circuit switching devices such as pseudomorphic high electron mobility transistors are used. In the paper, the switching voltage and current waveforms in the presence of ON-resistance are analyzed in order to provide insight into circuit properties such as RF output power, drain efficiency, and power-output capability. For a given amplifier specification, a design procedure is illustrated whereby it is possible to compute optimal circuit component values which account for prescribed switch resistance loss. Furthermore, insight into how ON-resistance affects transistor selection in terms of peak switch voltage and current requirements is described. Finally, a design example is given in order to validate the theoretical analysis against numerical simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we show that a multilayer freestanding slot array can be designed to give an insertion loss which is significantly lower than the value obtainable from a conventional dielectric backed printed frequency selective surface (FSS). This increase in filter efficiency is highlighted by comparing the performance of two structures designed to provide frequency selective beamsplitting in the quasioptical feed train of a submillimeter wave space borne radiometer. A two layer substrateless FSS providing more than 20 dB of isolation between the bands 316.5â??325.5 GHz and 349.5â??358.5 GHz, gives an insertion loss of 0.6 dB when the filter is orientated at 45 incidence in the TM plane, whereas the loss exhibited by a conventional printed FSS is in excess of 2 dB. A similar frequency response can be obtained in the TE plane, but here a triple screen structure is required and the conductor loss is shown to be comparable to the absorption loss of a dielectric backed FSS. Experimental devices have been fabricated using a precision micromachining technique. Transmission measurements performed in the range 250â??360 GHz are in good agreement with the simulated spectral performance of the individual periodic screens and the two multilayer freestanding FSS structures.