101 resultados para Traduction de tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An extensive chloride profiling program was undertaken on concrete pier stems erected in the vicinity of the Dornoch Bridge located at the Dornoch Firth in Northeast Scotland. The pier stems were 2 m (6.562 ft) high and octagonal in plan with 0.66 m (2.165 ft) wide faces. The piers were constructed in sets of three with the lowest of each set in the tidal zone and the highest in the atmospheric zone. The pier stems were placed in such a way that they would represent the exposure conditions of the actual bridge piers of the Dornoch Bridge. In all, six of the pier stems were made using plain ordinary portland cement (OPC) concrete (with three of these having the surface treated with silane); the remaining three pier stems had a concrete containing caltite as an additive. Three exposurezones were studied: the tidal zone, the splash zone, and the atmospheric zone. The tidal zone was further subdivided into two levels defined as low-level and high-level. Chloride profiles were obtained from the different regimes over a period of 7 years for all nine pier stems. This paper describes the nature of chloride ingress and the usefulness of diffusion parameters in classifying each exposure regimes. Furthermore, the effectiveness of silane and caltite in protecting concrete from chloride ingress in different exposure zones was studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the experimental results of loading tests on two 18m span tapered member portal frames designed to BS 5950. Deflection test results for vertical, lateral and combined loading cases are compared with the predictions given by elastic analysis to BS 5950 and shown to be favourable. The predicted ultimate capacities and modes of failure, which were by lateral-torsional buckling of the columns, were also found to agree with the experimental behaviour. It was found that the method of modelling the tapered members as a series of prismatic elements gave good comparison with test results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The LifeShirt is a novel ambulatory monitoring system that records cardio respiratory measurements outside the laboratory. Validity and reliability of cardiorespiratory measurements recorded by the LifeShirt were assessed and two methods of calibrating the LifeShirt were compared. Participants performed an incremental treadmill test and a constant work rate test (65% peak oxygen uptake) on four occasions (>48 In apart) and wore the LifeShirt, COSMED system and Polar Sport Tester simultaneously. The LifeShirt was calibrated using two methods: comparison to a spirometer; and 800 ml fixed-volume bag. Ventilation, respiratory rate, expiratory time and heart rate recorded by the LifeShirt were compared to measurements recorded by laboratory equipment. Sixteen adults participated (6M: 10F); mean (SD) age 23.1 (2.9) years. Agreement between the LifeShirt and laboratory equipment was acceptable. Agreement for ventilation was improved by calibrating the LifeShirt using a spirometer. Reliability was similar for the LifeShirt and the laboratory equipment. This study suggests that the LifeShirt provides a valid and reliable method of ambulatory monitoring. (C) 2009 Elsevier B.V. All rights reserved.