28 resultados para Time duration.
Resumo:
Seabirds are central place foragers during the breeding season and, as marine food resources are often patchily distributed, flexibility in foraging behaviour may be important in maintaining prey delivery rates to chicks. We developed a methodological approach using a combination of GPS data loggers and temperature-depth recorders that allowed us to describe the behaviour of surface-feeding seabirds. Specifically, we tested whether differences in foraging behaviour of black-legged kittiwakes Rissa tridactyla could be linked with reproductive success by comparing 2 consecutive years at 2 sites. At Rathlin Island (Northern Ireland) during 2010, foraging differed markedly from that during 2009 and from that at Lambay Island (Republic of Ireland) during both years. Birds exhibited foraging trips of greater duration, travelled a greater total distance, spent more time in transit and spent longer recuperating on the surface of the water. This notable shift was associated with a decline in breeding success, with greater loss of eggs to predation and lower prey delivery rates, resulting in the starvation of 15 % of chicks. We suggest that food resources were reduced or geographically less accessible during 2010, with suitable foraging areas located further from the colony. Birds did not invest greater amounts of time attempting to catch prey. Thus, our results indicate that kittiwakes at Rathlin modulated their foraging behaviour not by increasing foraging effort through feeding more intensively within prey patches but by extending their range to increase the probability of encountering more profitable prey patches. © Inter-Research 2012.
Resumo:
Background: Rift Valley fever (RVF) is a zoonotic arbovirosis for which the primary hosts are domestic livestock (cattle, sheep and goats). RVF was first described in South Africa in 1950-1951. Mechanisms for short and long distance transmission have been hypothesised, but there is little supporting evidence. Here we describe RVF occurrence and spatial distribution in South Africa in 2008-11, and investigate the presence of a contagious process in order to generate hypotheses on the different mechanisms of transmission. Methodology/Principal Findings: A total of 658 cases were extracted from World Animal Health Information Database. Descriptive statistics, epidemic curves and maps were produced. The space-time K-function was used to test for evidence of space-time interaction. Five RVF outbreak waves (one in 2008, two in 2009, one in 2010 and one in 2011) of varying duration, location and size were reported. About 70% of cases (n = 471) occurred in 2010, when the epidemic was almost country-wide. No strong evidence of space-time interaction was found for 2008 or the second wave in 2009. In the first wave of 2009, a significant space-time interaction was detected for up to one month and over 40 km. In 2010 and 2011 a significant intense, short and localised space-time interaction (up to 3 days and 15 km) was detected, followed by one of lower intensity (up to 2 weeks and 35 to 90 km). Conclusions/Significance: The description of the spatiotemporal patterns of RVF in South Africa between 2008 and 2011 supports the hypothesis that during an epidemic, disease spread may be supported by factors other than active vector dispersal. Limitations of under-reporting and space-time K-function properties are discussed. Further spatial analyses and data are required to explain factors and mechanisms driving RVF spread. © 2012 Métras et al.
Resumo:
BACKGROUND: Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent.
OBJECTIVES: To assess the effects of protocolized weaning from mechanical ventilation on the total duration of mechanical ventilation for critically ill adults; ascertain differences between protocolized and non-protocolized weaning in terms of mortality, adverse events, quality of life, weaning duration, intensive care unit (ICU) and hospital length of stay (LOS); and explore variation in outcomes by type of ICU, type of protocol and approach to delivering the protocol.
SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 1, 2010), MEDLINE (1950 to 2010), EMBASE (1988 to 2010), CINAHL (1937 to 2010), LILACS (1982 to 2010), ISI Web of Science and ISI Conference Proceedings (1970 to 2010), Cambridge Scientific Abstracts (inception to 2010) and reference lists of articles. We did not apply language restrictions.
SELECTION CRITERIA: We included randomized and quasi-randomized controlled trials of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults.
DATA COLLECTION AND ANALYSIS: Three authors independently assessed trial quality and extracted data. A priori subgroup and sensitivity analyses were performed. We contacted study authors for additional information.
MAIN RESULTS: Eleven trials that included 1971 patients met the inclusion criteria. The total duration of mechanical ventilation geometric mean in the protocolized weaning group was on average reduced by 25% compared with the usual care group (N = 10 trials, 95% CI 9% to 39%, P = 0.006); weaning duration was reduced by 78% (N = 6 trials, 95% CI 31% to 93%, P = 0.009); and ICU LOS by 10% (N = 8 trials, 95% CI 2% to 19%, P = 0.02). There was significant heterogeneity among studies for total duration of mechanical ventilation (I(2) = 76%, P <0.01) and weaning duration (I(2) = 97%, P <0.01), which could not be explained by subgroup analyses based on type of unit or type of approach.
AUTHORS' CONCLUSIONS: There is some evidence of a reduction in the duration of mechanical ventilation, weaning duration and ICU LOS with use of standardized protocols, but there is significant heterogeneity among studies and an insufficient number of studies to investigate the source of this heterogeneity. Although some study authors suggest that organizational context may influence outcomes, these factors were not considered in all included studies and therefore could not be evaluated.
Resumo:
Nonspecific changes (nonspecific chronic inflammation) in patients with chronic diarrhea represent the commonest diagnosis in colorectal biopsy interpretation, but these changes are of little clinical significance.
Resumo:
Background:Mechanical ventilation is a critical component of paediatric intensive care therapy. It is indicated when the patient’s spontaneous ventilation is inadequate to sustain life. Weaning is the gradual reduction of ventilatory support and the transfer of respiratory control back to the patient. Weaning may represent a large proportion of the ventilatory period. Prolonged ventilation is associated with significant morbidity, hospital cost, psychosocial and physical risks to the child and even death. Timely and effective weaning may reduce the duration of mechanical ventilation and may reduce the morbidity and mortality associated with prolonged ventilation. However, no consensus has been reached on criteria that can be used to identify when patients are ready to wean or the best way to achieve it.Objectives:To assess the effects of weaning by protocol on invasively ventilated critically ill children. To compare the total duration of invasive mechanical ventilation of critically ill children who are weaned using protocols versus those weaned through usual (non-protocolized) practice. To ascertain any differences between protocolized weaning and usual care in terms of mortality, adverse events, intensive care unit length of stay and quality of life.Search methods:We searched the Cochrane Central Register of Controlled Trials (CENTRAL; The Cochrane Library, Issue 10, 2012), MEDLINE (1966 to October 2012), EMBASE (1988 to October 2012), CINAHL (1982 to October 2012), ISI Web of Science and LILACS. We identified unpublished data in the Web of Science (1990 to October 2012), ISI Conference Proceedings (1990 to October 2012) and Cambridge Scientific Abstracts (earliest to October 2012). We contacted first authors of studies included in the review to obtain further information on unpublished studies or work in progress. We searched reference lists of all identified studies and review papers for further relevant studies. We applied no language or publication restrictions.Selection criteriaWe included randomized controlled trials comparing protocolized weaning (professional-led or computer-driven) versus non-protocolized weaning practice conducted in children older than 28 days and younger than 18 years.Data collection and analysis:Two review authors independently scanned titles and abstracts identified by electronic searching. Three review authors retrieved and evaluated full-text versions of potentially relevant studies, independently extracted data and assessed risk of bias.Main results:We included three trials at low risk of bias with 321 children in the analysis. Protocolized weaning significantly reduced total ventilation time in the largest trial (260 children) by a mean of 32 hours (95% confidence interval (CI) 8 to 56; P = 0.01). Two other trials (30 and 31 children, respectively) reported non-significant reductions with a mean difference of -88 hours (95% CI -228 to 52; P = 0.2) and -24 hours (95% CI -10 to 58; P = 0.06). Protocolized weaning significantly reduced weaning time in these two smaller trials for a mean reduction of 106 hours (95% CI 28 to 184; P = 0.007) and 21 hours (95% CI 9 to 32; P < 0.001). These studies reported no significant effects for duration of mechanical ventilation before weaning, paediatric intensive care unit (PICU) and hospital length of stay, PICU mortality or adverse events.Authors' conclusions:Limited evidence suggests that weaning protocols reduce the duration of mechanical ventilation, but evidence is inadequate to show whether the achievement of shorter ventilation by protocolized weaning causes children benefit or harm.
Resumo:
During the benthic cultivation process of Mytilus edulis (blue mussels), wild mussel seed is often transplanted from naturally occurring subtidal beds to sheltered in-shore waters to be grown to a commercial size. The survival of these relaid mussels is ultimately a function of their quality and physiological condition upon relaying and it has been recognised that mussels can suffer from a loss in condition following transportation. We investigated whether the process of being transported to ongrowing plots had a negative effect on the physiological health and resultant behaviour of mussels by simulating transportation conditions in a controlled experiment. Mussels were kept, out of water, in plastic piping to recreate translocation conditions and further, we tested if depth held in a ship hold (0, 1.5 and 3 m) and length of time emersed (12, 24 and 48 h) affected mussel condition and behaviour. Physiological condition was assessed by quantifying mussel tissue pH and whole tissue glucose, glycogen, succinate and propionate concentrations. The rate of byssogenesis was also quantified to estimate recovery following a period of re-immersion. The depth at which mussels were held did not affect any of the physiological indicators of mussel stress but short-term byssus production was affected. Mussels held at 3 m produced fewer byssus threads during the first 72 h following re-immersion compared with mussels at 0 m (i.e. not buried) suggesting that depth held can impede recovery following transportation. Duration of emersion affected all stress indicators. Specifically, mussels held out of water for 48 h had a reduced physiological condition compared with those emersed for just 12 h. This work has practical implications for the benthic cultivation industry and based on these results we recommend that mussels are held out of water for less than 24 h prior to relaying to ensure physiological health and resultant condition is preserved.
Resumo:
Background: This is an update of a review last published in Issue 5, 2010, of The Cochrane Library. Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent. Objectives: The first objective of this review was to compare the total duration of mechanical ventilation of critically ill adults who were weaned using protocols versus usual (non-protocolized) practice.The second objective was to ascertain differences between protocolized and non-protocolized weaning in outcomes measuring weaning duration, harm (adverse events) and resource use (intensive care unit (ICU) and hospital length of stay, cost).The third objective was to explore, using subgroup analyses, variations in outcomes by type of ICU, type of protocol and approach to delivering the protocol (professional-led or computer-driven). Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library Issue 1, 2014), MEDLINE (1950 to January 2014), EMBASE (1988 to January 2014), CINAHL (1937 to January 2014), LILACS (1982 to January 2014), ISI Web of Science and ISI Conference Proceedings (1970 to February 2014), and reference lists of articles. We did not apply language restrictions. The original search was performed in January 2010 and updated in January 2014.Selection criteriaWe included randomized controlled trials (RCTs) and quasi-RCTs of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults. Data collection and analysis: Two authors independently assessed trial quality and extracted data. We performed a priori subgroup and sensitivity analyses. We contacted study authors for additional information. Main results: We included 17 trials (with 2434 patients) in this updated review. The original review included 11 trials. The total geometric mean duration of mechanical ventilation in the protocolized weaning group was on average reduced by 26% compared with the usual care group (N = 14 trials, 95% confidence interval (CI) 13% to 37%, P = 0.0002). Reductions were most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. Weaning duration was reduced by 70% (N = 8 trials, 95% CI 27% to 88%, P = 0.009); and ICU length of stay by 11% (N = 9 trials, 95% CI 3% to 19%, P = 0.01). There was significant heterogeneity among studies for total duration of mechanical ventilation (I2 = 67%, P < 0.0001) and weaning duration (I2 = 97%, P < 0.00001), which could not be explained by subgroup analyses based on type of unit or type of approach. Authors' conclusions: There is evidence of reduced duration of mechanical ventilation, weaning duration and ICU length of stay with use of standardized weaning protocols. Reductions are most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. However, significant heterogeneity among studies indicates caution in generalizing results. Some study authors suggest that organizational context may influence outcomes, however these factors were not considered in all included studies and could not be evaluated. Future trials should consider an evaluation of the process of intervention delivery to distinguish between intervention and implementation effects. There is an important need for further development and research in the neurosurgical population.
Resumo:
Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.
Resumo:
This paper proposes a continuous time Markov chain (CTMC) based sequential analytical approach for composite generation and transmission systems reliability assessment. The basic idea is to construct a CTMC model for the composite system. Based on this model, sequential analyses are performed. Various kinds of reliability indices can be obtained, including expectation, variance, frequency, duration and probability distribution. In order to reduce the dimension of the state space, traditional CTMC modeling approach is modified by merging all high order contingencies into a single state, which can be calculated by Monte Carlo simulation (MCS). Then a state mergence technique is developed to integrate all normal states to further reduce the dimension of the CTMC model. Moreover, a time discretization method is presented for the CTMC model calculation. Case studies are performed on the RBTS and a modified IEEE 300-bus test system. The results indicate that sequential reliability assessment can be performed by the proposed approach. Comparing with the traditional sequential Monte Carlo simulation method, the proposed method is more efficient, especially in small scale or very reliable power systems.
Resumo:
The duration compression effect is a phenomenon in which prior adaptation to a spatially circumscribed dynamic stimulus results in the duration of subsequent subsecond stimuli presented in the adapted region being underestimated. There is disagreement over the frame of reference within which the duration compression phenomenon occurs. One view holds that the effect is driven by retinotopic-tuned mechanisms located at early stages of visual processing, and an alternate position is that the mechanisms are spatiotopic and occur at later stages of visual processing (MT+). We addressed the retinotopic-spatiotopic question by using adapting stimuli – drifting plaids - that are known to activate global-motion mechanisms in area MT. If spatiotopic mechanisms contribute to the duration compression effect, drifting plaid adaptors should be well suited to revealing them. Following adaptation participants were tasked with estimating the duration of a 600ms random dot stimulus, whose direction was identical to the pattern direction of the adapting plaid, presented at either the same retinotopic or the same spatiotopic location as the adaptor. Our results reveal significant duration compression in both conditions, pointing to the involvement of both retinotopic-tuned and spatiotopic-tuned mechanisms in the duration compression effect.
Resumo:
Recent studies have shown that cancer risk related to overweight and obesity is mediated by time and might be better approximated by using life years lived with excess weight. In this study we aimed to assess the impact of overweight duration and intensity in older adults on the risk of developing different forms of cancer. Study participants from seven European and one US cohort study with two or more weight assessments during follow-up were included (n = 329,576). Trajectories of body mass index (BMI) across ages were estimated using a quadratic growth model; overweight duration (BMI ≥ 25) and cumulative weighted overweight years were calculated. In multivariate Cox models and random effects analyses, a longer duration of overweight was significantly associated with the incidence of obesity-related cancer [overall hazard ratio (HR) per 10-year increment: 1.36; 95 % CI 1.12-1.60], but also increased the risk of postmenopausal breast and colorectal cancer. Additionally accounting for the degree of overweight further increased the risk of obesity-related cancer. Risks associated with a longer overweight duration were higher in men than in women and were attenuated by smoking. For postmenopausal breast cancer, increased risks were confined to women who never used hormone therapy. Overall, 8.4 % of all obesity-related cancers could be attributed to overweight at any age. These findings provide further insights into the role of overweight duration in the etiology of cancer and indicate that weight control is relevant at all ages. This knowledge is vital for the development of effective and targeted cancer prevention strategies.
Resumo:
OBJECTIVE: To compare the overall performance of specially trained neonatal nurses acting autonomously, unsupervised, and without a protocol with specialist registrars when weaning neonates from mechanical ventilation.
DESIGN: Prospective, randomized, controlled trial.
SETTING: A single neonatal intensive care unit.
PATIENTS: Neonates requiring conventional mechanical ventilation (n = 50).
INTERVENTIONS: Infants on conventional ventilation were randomly assigned to receive either nurse-led (n = 25) or registrar-led (n = 23) weaning. A total of 48 infants completed the study (two infants in the registrar group were excluded when their parents withdrew consent).
MEASUREMENTS AND MAIN RESULTS: The main outcome measure, median weaning time, was 1200 mins (95% confidence interval [CI], 621-1779 mins) in the nurse group and 3015 mins (95% CI, 2650-3380 mins) in the registrar group (p = .0458). The median time from treatment assignment to the first ventilator change was 60 mins (95% CI, 52-68 mins) in the nurse group and 120 mins (95% CI, 103-137 mins) in the registrar group (p = .35). On average, the nurses made ventilator changes every 4.5 hrs (95% CI, 2.9-6 hrs) and the registrars every 7.2 hrs (95% CI, 5.4-9 hrs; p = .003). The median number (range) of backward steps taken per infant was 0 (0-5 steps) in the nurse group and 1 (0-5 steps) in the registrar group (p = .019).
CONCLUSIONS: The findings of this study suggest that additional domains of neonatal critical care could be reviewed for their potential transfer to appropriately prepared nurses.
Resumo:
Background: Delirium is frequently diagnosed in critically ill patients and is associated with poor clinical outcomes. Haloperidol is the most commonly used drug for delirium despite little evidence of its effectiveness. The aim of this study was to establish whether early treatment with haloperidol would decrease the time that survivors of critical illness spent in delirium or coma. Methods: We did this double-blind, placebo-controlled randomised trial in a general adult intensive care unit (ICU). Critically ill patients (≥18 years) needing mechanical ventilation within 72 h of admission were enrolled. Patients were randomised (by an independent nurse, in 1:1 ratio, with permuted block size of four and six, using a centralised, secure web-based randomisation service) to receive haloperidol 2·5 mg or 0·9% saline placebo intravenously every 8 h, irrespective of coma or delirium status. Study drug was discontinued on ICU discharge, once delirium-free and coma-free for 2 consecutive days, or after a maximum of 14 days of treatment, whichever came first. Delirium was assessed using the confusion assessment method for the ICU (CAM-ICU). The primary outcome was delirium-free and coma-free days, defined as the number of days in the first 14 days after randomisation during which the patient was alive without delirium and not in coma from any cause. Patients who died within the 14 day study period were recorded as having 0 days free of delirium and coma. ICU clinical and research staff and patients were masked to treatment throughout the study. Analyses were by intention to treat. This trial is registered with the International Standard Randomised Controlled Trial Registry, number ISRCTN83567338. Findings: 142 patients were randomised, 141 were included in the final analysis (71 haloperidol, 70 placebo). Patients in the haloperidol group spent about the same number of days alive, without delirium, and without coma as did patients in the placebo group (median 5 days [IQR 0-10] vs 6 days [0-11] days; p=0·53). The most common adverse events were oversedation (11 patients in the haloperidol group vs six in the placebo group) and QTc prolongation (seven patients in the haloperidol group vs six in the placebo group). No patient had a serious adverse event related to the study drug. Interpretation: These results do not support the hypothesis that haloperidol modifies duration of delirium in critically ill patients. Although haloperidol can be used safely in this population of patients, pending the results of trials in progress, the use of intravenous haloperidol should be reserved for short-term management of acute agitation. Funding: National Institute for Health Research. © 2013 Elsevier Ltd.