22 resultados para Tests de non corrélation
Resumo:
This study explored the validity of using critical thinking tests to predict final psychology degree marks over and above that already predicted by traditional admission exams (A-levels). Participants were a longitudinal sample of 109 psychology students from a university in the United Kingdom. The outcome measures were: total degree marks; and end of year marks. The predictor measures were: university admission exam results (A-levels); critical thinking test scores (skills & dispositions); and non-verbal intelligence scores. Hierarchical regressions showed A-levels significantly predicted 10% of the final degree score and the 11-item measure of ‘Inference skills’ from the California Critical Thinking Skills Test significantly predicted an additional 6% of degree outcome variance. The findings from this study should inform decisions about the precise measurement constructs included in aptitude tests used in the higher education admission process.
Resumo:
OBJECTIVE: To examine a panel of 28 biomarkers for prediction of cardiovascular disease (CVD) and non-CVD mortality in a population-based cohort of men.
METHODS: Starting in 1979, middle-aged men in Caerphilly underwent detailed medical examination. Subsequently 2171 men were re-examined during 1989-1993, and fasting blood samples obtained from 1911 men (88%). Fibrinogen, viscosity and white cell count (WCC), routine biochemistry tests and lipids were analysed using fresh samples. Stored aliquots were later analysed for novel biomarkers. Statistical analysis of CVD and non-CVD mortality follow-up used competing risk Cox regression models with biomarkers in thirds tested at the 1% significance level after covariate adjustment.
RESULTS: During an average of 15.4years follow-up, troponin (subhazard ratio per third 1.71, 95% CI 1.46-1.99) and B-natriuretic peptide (BNP) (subhazard ratio per third 1.54, 95% CI 1.34-1.78) showed strong trends with CVD death but not with non-CVD death. WCC and fibrinogen showed similar weaker findings. Plasma viscosity, growth differentiation factor 15 (GDF-15) and interleukin-6 (IL-6) were associated positively with both CVD death and non-CVD death while total cholesterol was associated positively with CVD death but negatively with non-CVD death. C-reactive protein (C-RP), alkaline phosphatase, gamma-glutamyltransferase (GGT), retinol binding protein 4 (RBP-4) and vitamin B6 were significantly associated only with non-CVD death, the last two negatively. Troponin, BNP and IL-6 showed evidence of diminishing associations with CVD mortality through follow-up.
CONCLUSION: Biomarkers for cardiac necrosis were strong, specific predictors of CVD mortality while many inflammatory markers were equally predictive of non-CVD mortality.
Resumo:
This paper describes large scale tests conducted on a novel unglazed solar air collector system. The proposed system, referred to as a back-pass solar collector (BPSC), has on-site installation and aesthetic advantages over conventional unglazed transpired solar collectors (UTSC) as it is fully integrated within a standard insulated wall panel. This paper presents the results obtained from monitoring a BPSC wall panel over one year. Measurements of temperature, wind velocity and solar irradiance were taken at multiple air mass flow rates. It is shown that the length of the collector cavities has a direct impact on the efficiency of the system. It is also shown that beyond a height-to-flow ratio of 0.023m/m<sup>3</sup>/hr/m<sup>2</sup>, no additional heat output is obtained by increasing the collector height for the experimental setup in this study, but these numbers would obviously be different if the experimental setup or test environment (e.g. location and climate) change. An equation for predicting the temperature rise of the BPSC is proposed.
Resumo:
BACKGROUND: The transtheoretical model has been successful in promoting health behavior change in general and clinical populations. However, there is little knowledge about the application of the transtheoretical model to explain physical activity behavior in individuals with non-cystic fibrosis bronchiectasis. The aim was to examine patterns of (1) physical activity and (2) mediators of behavior change (self-efficacy, decisional balance, and processes of change) across stages of change in individuals with non-cystic fibrosis bronchiectasis.
METHODS: Fifty-five subjects with non-cystic fibrosis bronchiectasis (mean age ± SD = 63 ± 10 y) had physical activity assessed over 7 d using an accelerometer. Each component of the transtheoretical model was assessed using validated questionnaires. Subjects were divided into groups depending on stage of change: Group 1 (pre-contemplation and contemplation; n = 10), Group 2 (preparation; n = 20), and Group 3 (action and maintenance; n = 25). Statistical analyses included one-way analysis of variance and Tukey-Kramer post hoc tests.
RESULTS: Physical activity variables were significantly (P < .05) higher in Group 3 (action and maintenance) compared with Group 2 (preparation) and Group 1 (pre-contemplation and contemplation). For self-efficacy, there were no significant differences between groups for mean scores (P = .14). Decisional balance cons (barriers to being physically active) were significantly lower in Group 3 versus Group 2 (P = .032). For processes of change, substituting alternatives (substituting inactive options for active options) was significantly higher in Group 3 versus Group 1 (P = .01), and enlisting social support (seeking out social support to increase and maintain physical activity) was significantly lower in Group 3 versus Group 2 (P = .038).
CONCLUSIONS: The pattern of physical activity across stages of change is consistent with the theoretical predictions of the transtheoretical model. Constructs of the transtheoretical model that appear to be important at different stages of change include decisional balance cons, substituting alternatives, and enlisting social support. This study provides support to explore transtheoretical model-based physical activity interventions in individuals with non-cystic fibrosis bronchiectasis.
Resumo:
Temperament tests are widely accepted as instruments for profiling behavioral variability in dogs, and they are applied in numerous areas of investigation (e.g. suitability for adoption or for breeding). During testing, to elicit a dog's reaction toward novel stimuli and predict its behavior in everyday life, model devices such as a child-like doll, or a fake dog, are often employed. However, the reliability of these devices to accurately stimulate dogs' reactions to children or dogs, is unknown and perhaps overestimated. This may be a particular concern in the case of aggressive behavior toward humans, a significant public health issue. The aim of this study was to: (1) evaluate the correlation between dogs' reactions to these devices, and owners' reports of their dog's aggression history (using the C-BARQ ??); (2) compare reactions toward the devices of dogs with and without histories of aggression. Subjects were selected among those visiting for behavioral consultation at the Veterinary Hospital of the University of Pennsylvania, and previously categorized as aggressive toward unfamiliar children, conspecifics, or as non-aggressive dogs (control). The test consisted of different components: an unfamiliar female tester approaching the dog; the presentation of a child-like doll, an ambiguous object, and a fake plastic dog. All tests were videotaped and durations of behaviors were later analyzed on the basis of a specified ethogram. Dogs' reactions were compared to C-BARQ scores, and interesting correlations emerged for 'dog-directed aggression/fear' (R = 0.48, P = 0.004), and 'stranger-directed aggression' (R = 0.58, P <0.001) factors. Dogs differed in their reactions toward the devices: the child-like doll and the fake dog elicited more social behaviors than the ambiguous object used as a control stimulus. Issues concerning the reliability of these tools to assess canine temperament are discussed. ?? 2012 Elsevier B.V. All rights reserved.
Resumo:
Roadside safety barriers designs are tested with passenger cars in Europe using standard EN1317 in which the impact angle for normal, high and very high containment level tests is 20°. In comparison to EN1317, the US standard MASH has higher impact angles for cars and pickups (25°) and different vehicle masses. Studies in Europe (RISER) and the US have shown values for the 90th percentile impact angle of 30°–34°. Thus, the limited evidence available suggests that the 20° angle applied in EN 1317 may be too low.
The first goal of this paper is to use the US NCHRP database (Project NCHRP 17–22) to assess the distribution of impact angle and collision speed in recent ROR accidents. Second, based on the findings of the statistical analysis and on analysis of impact angles and speeds in the literature, an LS-DYNA finite element analysis was carried out to evaluate the normal containment level of concrete barriers in non-standard collisions. The FE model was validated against a crash test of a portable concrete barrier carried out at the UK Transport Research Laboratory (TRL).
The accident data analysis for run-off road accidents indicates that a substantial proportion of accidents have an impact angle in excess of 20°. The baseline LS-DYNA model showed good comparison with experimental acceleration severity index (ASI) data and the parametric analysis indicates a very significant influence of impact angle on ASI. Accordingly, a review of European run-off road accidents and the configuration of EN 1317 should be performed.
Resumo:
The cobas® (Roche) portfolio of companion diagnostics in oncology currently has three assays CE-marked for in vitro diagnostics. Two of these (EGFR and BRAF) are also US FDA-approved. These assays detect clinically relevant mutations that are correlated with response (BRAF, EGFR) or lack of response (KRAS) to targeted therapies such as selective mutant BRAF inhibitors in malignant melanoma, tyrosine kinases inhibitor in non-small cell lung cancer and anti-EGFR monoclonal antibodies in colorectal cancer, respectively. All these assays are run on a single platform using DNA extracted from a single 5 µm section of a formalin-fixed paraffin-embedded tissue block. The assays provide an ‘end-to-end’ solution from extraction of DNA to automated analysis and report on the cobas z 480. The cobas tests have shown robust and reproducible performance, with high sensitivity and specificity and low limit of detection, making them suitable as companion diagnostics for clinical use.