60 resultados para SCINTILLATION COUNTING
Resumo:
Cell counting of bronchoalveolar lavage (BAL) fluid is performed manually in routine practice. This has both methodological and inherent errors; however, the accuracy and suitability of automated counting devices have been questioned. In this study, a Coulter(R) Counter D Industrial model was calibrated and then used to measure the total cell count in unprocessed bronchoalveolar lavage fluid, and compared to a standard manual method.
Resumo:
(With R. Geary.)
Resumo:
In response to claims that the quality (and in particular linearity) of children's mental representation of number acts as a constraint on number development, we carried out a longitudinal assessment of the relationships between number line estimation, counting, and mathematical abilities. Ninety-nine 5-year-olds were tested on 4 occasions at 3 monthly intervals. Correlations between the 3 types of ability were evident, but while the quality of children's estimations changed over time and performance on the mathematical tasks improved over the same period, changes in one were not associated with changes in the other. In contrast to the earlier claims that the linearity of number representation is potentially a unique contributor to children's mathematical development, the data suggest that this variable is not significantly privileged in its impact over and above simple procedural number skills. We propose that both early arithmetic success and estimating skill are bound closely to developments in counting ability.
Resumo:
Double beam modulation is widely used in atomic collision experiments in the case where the noise arising froth each of the beams exceeds the measured signal. A method for minimizing the statistical uncertainty in a measured signal in a given time period is discussed, and a flexible modulation and counting system based on a low cost PIC microcontroller is described. This device is capable of modifying the acquisition parameters in real time during the course of an experimental run. It is shown that typical savings in data acquisition time of approximately 30% can be achieved using this optimized modulation scheme.
Resumo:
We are discussing certain combinatorial and counting problems related to quadratic algebras. First we give examples which confirm the Anick conjecture on the minimal Hilbert series for algebras given by $n$ generators and $\frac {n(n-1)}{2}$ relations for $n \leq 7$. Then we investigate combinatorial structure of colored graph associated to relations of RIT algebra. Precise descriptions of graphs (maps) corresponding to algebras with maximal Hilbert series are given in certain cases. As a consequence it turns out, for example, that RIT algebra may have a maximal Hilbert series only if components of the graph associated to each color are pairwise 2-isomorphic.
Resumo:
Reported mast-cell counts in endobronchial biopsies from asthmatic subjects are conflicting, with different methodologies often being used. This study compared three standard methods of counting mast cells in endobronchial biopsies from asthmatic and normal subjects. Endobronchial biopsies were obtained from atopic asthmatic subjects (n=17), atopic nonasthmatic subjects (n=6), and nonatopic nonasthmatic control subjects (n=5). After overnight fixation in Carnoy's fixative, mast cells were stained by the short and long toluidine blue methods and antitryptase immunohistochemistry and were counted by light microscopy. Method comparison was made according to Bland & Altman. The limits of agreement were unacceptable for each of the comparisons, suggesting that the methods are not interchangeable. Coefficients of repeatability were excellent, and not different for the individual techniques. These results suggest that some of the reported differences in mast-cell numbers in endobronchial biopsies in asthma may be due to the staining method used, making direct comparisons between studies invalid. Agreement on a standard method is required for counting mast cells in bronchial biopsies, and we recommend the immunohistochemical method, since fixation is less critical and the resultant tissue sections facilitate clear, accurate, and rapid counts.
Resumo:
We observed a stellar occultation by Titan on 2003 November 14 from La Palma Observatory using ULTRACAM with three Sloan filters: u, g, and i (358, 487, and 758 nm, respectively). The occultation probed latitudes 2°?S and 1°?N during immersion and emersion, respectively. A prominent central flash was present in only the i filter, indicating wavelength-dependent atmospheric extinction. We inverted the light curves to obtain six lower-limit temperature profiles between 335 and 485 km (0.04 and 0.003 mb) altitude. The i profiles agreed with the temperature measured by the Huygens Atmospheric Structure Instrument [Fulchignoni, M., and 43 colleagues, 2005. Nature 438, 785 791] above 415 km (0.01 mb). The profiles obtained from different wavelength filters systematically diverge as altitude decreases, which implies significant extinction in the light curves. Applying an extinction model [Elliot, J.L., Young, L.A., 1992. Astron. J. 103, 991 1015] gave the altitudes of line of sight optical depth equal to unity: 396±7 and 401±20 km (u immersion and emersion); 354±7 and 387±7 km (g immersion and emersion); and 336±5 and 318±4 km (i immersion and emersion). Further analysis showed that the optical depth follows a power law in wavelength with index 1.3±0.2. We present a new method for determining temperature from scintillation spikes in the occulting body's atmosphere. Temperatures derived with this method are equal to or warmer than those measured by the Huygens Atmospheric Structure Instrument. Using the highly structured, three-peaked central flash, we confirmed the shape of Titan's middle atmosphere using a model originally derived for a previous Titan occultation [Hubbard, W.B., and 45 colleagues, 1993. Astron. Astrophys. 269, 541 563].
Resumo:
Bradykinin and related peptides are found in the defensive skin secretions of many frogs and toads. While the physiological roles of bradykinin-related peptides in sub-mammalian vertebrates remains obscure, in mammals, including humans, canonical bradykinin mediates a multitude of biological effects including the proliferation of many types of cancer cell. Here we have examined the effect of the bradykinin B2 receptor antagonist peptide, kinestatin, originally isolated by our group from the skin secretion of the giant fire-bellied toad, Bombina maxima, on the proliferation of the human prostate cancer cell lines, PC3, DU175 and LnCAP. The bradykinin receptor status of all cell lines investigated was established through PCR amplification of transcripts encoding both B1 and B2 receptor subtypes. Following this demonstration, all cell lines were grown in the presence or absence of kinestatin and several additional bradykinin receptor antagonists of amphibian skin origin and the effects on proliferation of the cell lines was investigated using the MTT assay and by counting of the cells in individual wells of 96-well plates. All of the amphibian skin secretion-derived bradykinin receptor antagonists inhibited proliferation of all of the prostate cancer lines investigated in a dose-dependent manner. In addition, following incubation of peptides with each cell line and analysis of catabolites by mass spectrometry, it was found that bradykinin was highly labile and each antagonist was highly stable under the conditions employed. Bradykinin signalling pathways are thus worthy of further investigation in human prostate cancer cell lines and the evidence presented here would suggest the testing of efficacy in animal models of prostate cancer as a positive outcome could lead to a drug development programme for the treatment of this disease.
Resumo:
It is noted that the determination of an oscillation frequency by used of the power spectrum of measured time series is susceptible to filtering of the signal. Similarly, frequency measurements made by period counting can yield different, results depending on how the signal is filtered for noise reduction. In an attempt to eliminate these ambiguities, a new measure of frequency, based on an approximate reconstruction of the phase-space trajectory of the oscillator from the signal, is introduced. This measure is shown to be invariant under linear filtering. For this reason, it is also inaccessible by spectral methods. The effect of filtering on frequency for weakly nonlinear, noisy oscillators, to which this definition applies only imperfectly, is quantified. This work provides the theoretical basis for frequency measurements employing MIRVA filtering.
Resumo:
Baited cameras are often used for abundance estimation wherever alternative techniques are precluded, e.g. in abyssal systems and areas such as reefs. This method has thus far used models of the arrival process that are deterministic and, therefore, permit no estimate of precision.
Furthermore, errors due to multiple counting of fish and missing those not seen by the camera have restricted the technique to using only the time of first arrival, leaving a lot of data redundant. Here, we reformulate the arrival process using a stochastic model, which allows the precision of abundance
estimates to be quantified. Assuming a non-gregarious, cross-current-scavenging fish, we show that prediction of abundance from first arrival time is extremely uncertain. Using example data, we show
that simple regression-based prediction from the initial (rising) slope of numbers at the bait gives good precision, accepting certain assumptions. The most precise abundance estimates were obtained
by including the declining phase of the time series, using a simple model of departures, and taking account of scavengers beyond the camera’s view, using a hidden Markov model.
Resumo:
We present two novel bioassays to be used in the examination of plant-parasitic nematode host-finding ability. The host-finding 'pipette-bulb assay' was constructed from modelled Pasteur pipette bulbs and connecting barrels using parafilm fastenings. This assay examines the direction of second-stage juvenile (J2) migration in response to a host seedling, through a moistened sand substrate, which underlies terminal upward-facing 'seedling bulbs', one containing a host seedling in potting compost, the other with only potting compost. An equal watering regime through both upward-facing seedling bulbs creates a directional concentration gradient of host diffusate chemotactic factors. Positive chemotactic stimuli cause the J2 to orientate and migrate towards the host plant. We present validation data collected from assays of the root-knot nematode, Meloidogyne incognita, and the potato cyst nematode, Globodera pallida, which indicate a highly significant positive attraction of J2 of both species to respective host plants. This represents a simple, quick and inexpensive method of assessing host-finding behaviour in the laboratory. We consider that the pipette-bulb assay improves on previous host-finding/chemo-attraction assays through creating a more biologically relevant environment for experimental J2; analysis is quick and easy, allowing the straightforward interpretation of results. In addition, we have developed an 'agar trough' sensory assay variant which we believe can be used rapidly to ratify nematode responses to chemical gustatory or olfactory cues. This was constructed from a water agar substrate such that two counting wells were connected by a raised central trough, all flooded with water. Two small water agar plugs were dehydrated briefly in an oven and then hydrated in either an attractant, repellent or water control; these plugs were then placed in the terminal counting wells and subsequently leached the attractant or repellent to form a concentration gradient along the central trough, which contained the initial J2 innoculum. Our data show that both M. incognita and G. pallida J2 are positively attracted to host diffusates. In addition, they displayed a strong repulsion in response to 1 M NaCl2. J2 of M. incognita displayed a mild aversion to a non-host oak root diffusate, whereas G. pallida J2 displayed a strong aversion to the same non-host diffusate; neither species responded to a compost leachate. We believe that the agar trough assay improves on previous methods by facilitating rapid diffusion of attractant or repellents. Both of the aforementioned assays were designed as tools to assess the impact of RNAi-based reverse genetics screens for gene targets involved in chemosensory orientation.
Resumo:
As a diagnostic of high-intensity laser interactions (> 10(19) W cm(-2)), the detection of radioactive isotopes is regularly used for the characterization of proton, neutron, ion, and photon beams. This involves sample removal from the interaction chamber and time consuming post shot analysis using NaI coincidence counting or Ge detectors. This letter describes the use of in situ detectors to measure laser-driven (p,n) reactions in Al-27 as an almost real-time diagnostic for proton acceleration. The produced Si-27 isotope decays with a 4.16 s half-life by the predominantly beta+ emission, producing a strong 511 keV annihilation peak. (c) 2006 American Institute of Physics.