21 resultados para Robust Performance
Resumo:
The parasitical relationship between the grand piano and the myriad objects used in its preparation as pioneered by John Cage in the late 1940’s is here discussed from a perspective of free improvisation practice. Preparations can be defined as the use of a “non-instrument” object (screws, bolts, rubbers etc…) to alter or modify the behaviour of an instrument or part of an instrument. Although also present in instrumental practices based on the electric guitar or the drum kit, the piano provides a privileged space of exploration given its large‐scale resonant body. It also highlights the transgressive aspect of preparation (the piano to be prepared often belongs to a venue rather than to the pianist herself, hence highlighting relationships of trust, care and respect). Since 2007 I have used a guitar-object (a small wooden board with strings and pick ups) connected to a small amplifier to prepare the grand piano in my free improvisation practice. This paper addresses the different relationships afforded by this type preparation which is characterised by the fact that the object for preparation is in itself an instrument (albeit a simplified one), and the preparation is ephemeral and intrinsic to the performance. The paper also reflects on the process of designing an interface from and for a particular practice and in collaboration with a guitar luthier.
Resumo:
Background: Identifying new and more robust assessments of proficiency/expertise (finding new "biomarkers of expertise") in histopathology is desirable for many reasons. Advances in digital pathology permit new and innovative tests such as flash viewing tests and eye tracking and slide navigation analyses that would not be possible with a traditional microscope. The main purpose of this study was to examine the usefulness of time-restricted testing of expertise in histopathology using digital images.
Methods: 19 novices (undergraduate medical students), 18 intermediates (trainees), and 19 experts (consultants) were invited to give their opinion on 20 general histopathology cases after 1 s and 10 s viewing times. Differences in performance between groups were measured and the internal reliability of the test was calculated.
Results: There were highly significant differences in performance between the groups using the Fisher's least significant difference method for multiple comparisons. Differences between groups were consistently greater in the 10-s than the 1-s test. The Kuder-Richardson 20 internal reliability coefficients were very high for both tests: 0.905 for the 1-s test and 0.926 for the 10-s test. Consultants had levels of diagnostic accuracy of 72% at 1 s and 83% at 10 s.
Conclusions: Time-restricted tests using digital images have the potential to be extremely reliable tests of diagnostic proficiency in histopathology. A 10-s viewing test may be more reliable than a 1-s test. Over-reliance on "at a glance" diagnoses in histopathology is a potential source of medical error due to over-confidence bias and premature closure.
Resumo:
An efficient and robust case sorting algorithm based on Extended Equal Area Criterion (EEAC) is proposed in this paper for power system transient stability assessment (TSA). The time-varying degree of an equivalent image system can be deduced by comparing the analysis results of Static EEAC (SEEAC) and Dynamic EEAC (DEEAC), the former of which neglects all time-varying factors while the latter partially considers the time-varying factors. Case sorting rules according to their transient stability severity are set combining the time-varying degree and fault messages. Then a case sorting algorithm is designed with the “OR” logic among multiple rules, based on which each case can be identified into one of the following five categories, namely stable, suspected stable, marginal, suspected unstable and unstable. The performance of this algorithm is verified by studying 1652 contingency cases from 9 real Chinese provincial power systems under various operating conditions. It is shown that desirable classification accuracy can be achieved for all the contingency cases at the cost of very little extra computational burden and only 9.81% of the whole cases need to carry out further detailed calculation in rigorous on-line TSA conditions.
Resumo:
Electrochemical water splitting used for generating hydrogen has attracted increasingly attention due to energy and environmental issues. It is a major challenge to design an efficient, robust and inexpensive electrocatalyst to achieve preferable catalytic performance. Herein, a novel three-dimensional (3D) electrocatalyst was prepared by decorating nanostructured biological material-derived carbon nanofibers with in situ generated cobalt-based nanospheres (denoted as CNF@Co) through a facile approach. The interconnected porous 3D networks of the resulting CNF@Co catalyst provide abundant channels and interfaces, which remarkably favor both mass transfer and oxygen evolution. The as-prepared CNF@Co shows excellent electrocatalytic activity towards the oxygen evolution reactions with an onset potential of about 0.445 V vs. Ag/AgCl. It only needs a low overpotential of 314 mV to achieve a current density of 10 mA/cm<sup>2</sup> in 1.0 M KOH. Furthermore, the CNF@Co catalyst exhibits excellent stability towards water oxidation, even outperforming commercial IrO<inf>2</inf> and RuO<inf>2</inf> catalysts.
Resumo:
A relatively simple, selective, precise and accurate high performance liquid chromatography (HPLC) method based on a reaction of phenylisothiocyanate (PITC) with glucosamine (GL) in alkaline media was developed and validated to determine glucosamine hydrochloride permeating through human skin in vitro. It is usually problematic to develop an accurate assay for chemicals traversing skin because the excellent barrier properties of the tissue ensure that only low amounts of the material pass through the membrane and skin components may leach out of the tissue to interfere with the analysis. In addition, in the case of glucosamine hydrochloride, chemical instability adds further complexity to assay development. The assay, utilising the PITC-GL reaction was refined by optimizing the reaction temperature, reaction time and PITC concentration. The reaction produces a phenylthiocarbamyl-glucosamine (PTC-GL) adduct which was separated on a reverse-phase (RP) column packed with 5 microm ODS (C18) Hypersil particles using a diode array detector (DAD) at 245 nm. The mobile phase was methanol-water-glacial acetic acid (10:89.96:0.04 v/v/v, pH 3.5) delivered to the column at 1 ml min-1 and the column temperature was maintained at 30 degrees C. Galactosamine hydrochloride (Gal-HCl) was used as an internal standard. Using a saturated aqueous solution of glucosamine hydrochloride, in vitro permeation studies were performed at 32+/-1 degrees C over 48 h using human epidermal membranes prepared by a heat separation method and mounted in Franz-type diffusion cells with a diffusional area 2.15+/-0.1 cm2. The optimum derivatisation reaction conditions for reaction temperature, reaction time and PITC concentration were found to be 80 degrees C, 30 min and 1% v/v, respectively. PTC-Gal and GL adducts eluted at 8.9 and 9.7 min, respectively. The detector response was found to be linear in the concentration range 0-1000 microg ml-1. The assay was robust with intra- and inter-day precisions (described as a percentage of relative standard deviation, %R.S.D.) <12. Intra- and inter-day accuracy (as a percentage of the relative error, %RE) was <or=-5.60 and <or=-8.00, respectively. Using this assay, it was found that GL-HCl permeates through human skin with a flux 1.497+/-0.42 microg cm-2 h-1, a permeability coefficient of 5.66+/-1.6x10(-6) cm h-1 and with a lag time of 10.9+/-4.6 h.
Resumo:
Situational awareness is achieved naturally by the human senses of sight and hearing in combination. Automatic scene understanding aims at replicating this human ability using microphones and cameras in cooperation. In this paper, audio and video signals are fused and integrated at different levels of semantic abstractions. We detect and track a speaker who is relatively unconstrained, i.e., free to move indoors within an area larger than the comparable reported work, which is usually limited to round table meetings. The system is relatively simple: consisting of just 4 microphone pairs and a single camera. Results show that the overall multimodal tracker is more reliable than single modality systems, tolerating large occlusions and cross-talk. System evaluation is performed on both single and multi-modality tracking. The performance improvement given by the audio–video integration and fusion is quantified in terms of tracking precision and accuracy as well as speaker diarisation error rate and precision–recall (recognition). Improvements vs. the closest works are evaluated: 56% sound source localisation computational cost over an audio only system, 8% speaker diarisation error rate over an audio only speaker recognition unit and 36% on the precision–recall metric over an audio–video dominant speaker recognition method.