32 resultados para Radio measurements
Resumo:
Electron energy probability functions measured with a passively compensated Langmuir probe in asymmetric capacitively coupled hydrogen and deuterium plasmas exhibit structure. The otherwise relatively continuous distribution appears to have an abrupt peak in electron density near 5 eV. This structure occurs at a higher energy in deuterium than hydrogen and there is a correlation between floating potential and the voltage at which the structure is observed in the second derivative of the I(V) characteristic. While the cause of the structure has yet to be clarified, spectroscopic observations and computer-based hydrogen models indicate that the high energy tail of the distribution is strongly modulated during the radio frequency cycle. The effect of this modulation on plasma properties and probe measurements has yet to be explored. (C) 1999 American Institute of Physics. [S0003-6951(99)00819-0].
Resumo:
A time-resolved Langmuir probe technique is used to measure the dependence of the electron density, electron temperature, plasma potential and electron energy distribution function (EEDF) on the phase of the driving voltage in a RF driven parallel plate discharge. The measurements were made in a low-frequency (100-500 kHz), symmetrically driven, radio frequency discharge operating in H-2, D-2 and Ar at gas pressures of a few hundred millitorr. The EEDFs could not be represented by a single Maxwellian distribution and resembled the time averaged EEDFs reported in 13.56 MHz discharges. The measured parameters showed structure in their spatial and temporal dependence, generally consistent with a simple oscillating sheath model. Electron temperatures of less than 0.1 eV were measured during the phase of the RF cycle when both electrodes are negative with respect to the plasma.
Resumo:
Comparisons between experimentally measured time-dependent electron energy distribution functions and optical emission intensities are reported for low-frequency (100 and 400 kHz) radio-frequency driven discharges in argon. The electron energy distribution functions were measured with a time-resolved Langmuir probe system. Time-resolved optical emissions of argon resonance lines at 687.1 and 750.4 nm were determined by photon-counting methods. Known ground-state and metastable-state excitation cross sections were used along with the measured electron energy distribution functions to calculate the time dependence of the optical emission intensity. It was found that a calculation using only the ground-state cross sections gave the best agreement with the time dependence of the measured optical emission. Time-dependent electron density, electron temperature, and plasma potential measurements are also reported.
Resumo:
In this paper, the results of radio channel measurements between two hypothetical cellular handsets in an outdoor urban environment are reported. The device-to-device channel measurements were made at 868 MHz and investigated a number of different everyday usage scenarios such as the devices being held at the user's heads, placed in a pocket while one of the users rotated or both moved randomly. It was found that shadowing of the main signal path caused by the human body will be an important factor in future device-to-device communications at this frequency. The recently proposed shadowed κ-μ fading model was used to characterize these channels and shown to provide a good description of the measured data.
Resumo:
The University of Waikato, Hamilton, New Zealand and The Queen's University of Belfast, Northern Ireland radiocarbon dating laboratories have undertaken a series of high-precision measurements on decadal samples of dendrochronologically dated oak (Quercus petraea) from Great Britain and cedar (Libocedrus bidwillii) and silver pine (Lagarostrobos colensoi) from New Zealand. The results show an average hemispheric offset over the 900 yr of measurement of 40±13 yr. This value is not constant but varies with a periodicity of about 130 yr. The Northern Hemisphere measurements confirm the validity of the Pearson et al. (1986) calibration dataset.
Direct measurements of reaeration rates using noble gas tracers in the River Lagan, Northern Ireland
Resumo:
Joint quantum measurements of noncommuting observables are possible, if one accepts an increase in the measured variances. A necessary condition for a joint measurement to be possible is that a joint probability distribution exists for the measurement. This fact suggests that there may be a link with Bell inequalities, as these will be satisfied if and only if a joint probability distribution for all involved observables exists. We investigate the connections between Bell inequalities and conditions for joint quantum measurements to be possible. Mermin's inequality for the three-particle Greenberger-Horne-Zeilinger state turns out to be equivalent to the condition for a joint measurement on two out of the three quantum systems to exist. Gisin's Bell inequality for three coplanar measurement directions, meanwhile, is shown to be less strict than the condition for the corresponding joint measurement.
Resumo:
The removal of false coincidences from measurements of coincidences between two photoelectrons and one or two ions formed in molecular double photoionization is described. False coincidences arise by several mechanisms; experimental procedures and mathematical formulae required to remove all the different false coincidence contributions are described. Sample spectra taken of the double photoionization of carbon dioxide are presented to illustrate the method of false coincidence subtraction.
Resumo:
The density of metastable helium atoms in a dielectric barrier discharge operating in helium with some impurities present has been measured using laser-collisional-induced fluorescence and absorption techniques. Time-resolved measurements indicate that helium metastables contribute to the production of impurity ions, in this case N-2(+), in the postdischarge current phase of a glow discharge. In our particular discharge environment, the helium metastable density is (1.5+/-1.4)x10(10) cm(-3), a result consistent with failure to observe absorption by metastables in a multipass absorption measurement. (C) 2004 American Institute of Physics.
Resumo:
A technique is described whereby measurements of ions extracted from an electron beam ion trap can be used to deduce their temperature dynamics. The measured temperature dynamics shows the expected trend as a function of charge and also gives evidence for Landau-Spitzer heating, ionization heating and evaporative cooling.