23 resultados para Quality Control


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Although most gastrointestinal stromal tumours (GIST) carry oncogenic mutations in KIT exons 9, 11, 13 and 17, or in platelet-derived growth factor receptor alpha (PDGFRA) exons 12, 14 and 18, around 10% of GIST are free of these mutations. Genotyping and accurate detection of KIT/PDGFRA mutations in GIST are becoming increasingly useful for clinicians in the management of the disease. METHOD: To evaluate and improve laboratory practice in GIST mutation detection, we developed a mutational screening quality control program. Eleven laboratories were enrolled in this program and 50 DNA samples were analysed, each of them by four different laboratories, giving 200 mutational reports. RESULTS: In total, eight mutations were not detected by at least one laboratory. One false positive result was reported in one sample. Thus, the mean global rate of error with clinical implication based on 200 reports was 4.5%. Concerning specific polymorphisms detection, the rate varied from 0 to 100%, depending on the laboratory. The way mutations were reported was very heterogeneous, and some errors were detected. CONCLUSION: This study demonstrated that such a program was necessary for laboratories to improve the quality of the analysis, because an error rate of 4.5% may have clinical consequences for the patient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microneedles (MNs) are emerging devices that can be used for the delivery of drugs at specific locations1. Their performance is primarily judged by different features and the penetration through tissue is one of the most important aspects to evaluate. For detailed studies of MN performance different kind of in-vitro, exvivo and in-vivo tests should be performed. The main limitation of some of these tests is that biological tissue is too heterogeneous, unstable and difficult to obtain. In addition the use of biological materials sometimes present legal issues. There are many studies dealing with artificial membranes for drug diffusion2, but studies of artificial membranes for Microneedle mechanical characterization are scarce3. In order to overcome these limitations we have developed tests using synthetic polymeric membranes instead of biological tissue. The selected artificial membrane is homogeneous, stable, and readily available. This material is mainly composed of a roughly equal blend of a hydrocarbon wax and a polyolefin and it is commercially available under the brand name Parafilm®. The insertion of different kind of MN arrays prepared from crosslinked polymers were performed using this membrane and correlated with the insertion of the MN arrays in ex-vivo neonatal porcine skin. The insertion depth of the MNs was evaluated using Optical coherence tomography (OCT). The implementation of MN transdermal patches in the market can be improved by make this product user-friendly and easy to use. Therefore, manual insertion is preferred to other kind of procedures. Consequently, the insertion studies were performed in neonatal porcine skin and the artificial membrane using a manual insertion force applied by human volunteers. The insertion studies using manual forces correlated very well with the same studies performed with a Texture Analyzer equipment. These synthetic membranes seem to mimic closely the mechanical properties of the skin for the insertion of MNs using different methods of insertion. In conclusion, this artificial membrane substrate offers a valid alternative to biological tissue for the testing of MN insertion and can be a good candidate for developing a reliable quality control MN insertion test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The construction industry requires quality control and regulation of its contingent,unpredictable environment. However, taking too much control from workers candisempower and demotivate. In the 1970s Deci and Ryan developed selfdeterminationtheory which states that in order to be intrinsically motivated, threecomponents are necessary - competence, autonomy and relatedness. This study aimsto examine the way in which the three ‘nutriments’ for intrinsic motivation may beundermined by heavy-handed quality control. A critical literature review analysesconstruction, psychological and management research regarding the control andmotivation of workers, using self-determination theory as a framework. Initialfindings show that quality management systems do not always work as designed.Workers perceive that unnecessary, wasteful and tedious counter checking of theirwork implies that they are not fully trusted by management to work without oversight.Control of workers and pressure for continual improvement may lead to resistanceand deception. Controlling mechanisms can break the link between performance andsatisfaction, reducing motivation and paradoxically reducing the likelihood of thequality they intend to promote. This study will lead to a greater understanding ofcontrol and motivation, facilitating further research into improvements in theapplication of quality control to maintain employee motivation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A recent genome-wide association study reported association between schizophrenia and the ZNF804A gene on chromosome 2q32.1. We attempted to replicate these findings in our Irish Case-Control Study of Schizophrenia (ICCSS) sample (N=1021 cases, 626 controls). Following consultation with the original investigators, we genotyped three of the most promising single-nucleotide polymorphisms (SNPs) from the Cardiff study. We replicate association with rs1344706 (trend test one-tailed P=0.0113 with the previously associated A allele) in ZNF804A. We detect no evidence of association with rs6490121 in NOS1 (one-tailed P=0.21), and only a trend with rs9922369 in RGRIP1L (one-tailed P=0.0515). On the basis of these results, we completed genotyping of 11 additional linkage disequilibrium-tagging SNPs in ZNF804A. Of 12 SNPs genotyped, 11 pass quality control criteria and 4 are nominally associated, with our most significant evidence of association at rs7597593 (P=0.0013) followed by rs1344706. We observe no evidence of differential association in ZNF804A on the basis of family history or sex of case. The associated SNP rs1344706 lies in approximately 30 bp of conserved mammalian sequence, and the associated A allele is predicted to maintain binding sites for the brain-expressed transcription factors MYT1l and POU3F1/OCT-6. In controls, expression is significantly increased from the A allele of rs1344706 compared with the C allele. Expression is increased in schizophrenic cases compared with controls, but this difference does not achieve statistical significance. This study replicates the original reported association of ZNF804A with schizophrenia and suggests that there is a consistent link between the A allele of rs1344706, increased expression of ZNF804A and risk for schizophrenia.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

INTRODUCTION: EGFR screening requires good quality tissue, sensitivity and turn-around time (TAT). We report our experience of routine screening, describing sample type, TAT, specimen quality (cellularity and DNA yield), histopathological description, mutation result and clinical outcome. METHODS: Non-small cell lung cancer (NSCLC) sections were screened for EGFR mutations (M+) in exons 18-21. Clinical, pathological and screening outcome data were collected for year 1 of testing. Screening outcome alone was collected for year 2. RESULTS: In year 1, 152 samples were tested, most (72%) were diagnostic. TAT was 4.9 days (95%confidence interval (CI)=4.5-5.5). EGFR-M+ prevalence was 11% and higher (20%) among never-smoking women with adenocarcinomas (ADCs), but 30% of mutations occurred in current/ex-smoking men. EGFR-M+ tumours were non-mucinous ADCs and 100% thyroid transcription factor (TTF1+). No mutations were detected in poorly differentiated NSCLC-not otherwise specified (NOS). There was a trend for improved overall survival (OS) among EGFR-M+ versus EGFR-M- patients (median OS=78 versus 17 months). In year 1, test failure rate was 19%, and associated with scant cellularity and low DNA concentrations. However 75% of samples with poor cellularity but representative of tumour were informative and mutation prevalence was 9%. In year 2, 755 samples were tested; mutation prevalence was 13% and test failure only 5.4%. Although samples with low DNA concentration (2.2 ng/μL), the mutation rate was 9.2%. CONCLUSION: Routine epidermal growth factor receptor (EGFR) screening using diagnostic samples is fast and feasible even on samples with poor cellularity and DNA content. Mutations tend to occur in better-differentiated non-mucinous TTF1+ ADCs. Whether these histological criteria may be useful to select patients for EGFR testing merits further investigation.