45 resultados para Q-burst
Resumo:
A narrow band proton bursts at energies of 1.6 +/- 0.08 MeV were observed when a water spray consisting of empty set(150 nm)-diameter droplets was irradiated by an ultrashort laser pulse of about 45 fs duration and at an intensity of 5 X 10(19) W/cm(2). The results are explained by a Coulomb explosion of sub-laser-wavelength droplets composed of two ion species. The laser prepulse plays an important role. By pre-evaporation of the droplets, its diameter is reduced so that the main pulse can interact with a smaller droplet, and this remaining bulk can be ionized to high states. In the case of water, the mixture of quite differently charged ions establishes an
Resumo:
In a recent experimental study, the beam intensity profile of the Vulcan petawatt laser beam was measured; it was found that only 20% of the energy was contained within the full width at half maximum of 6.9 mu m and 50% within 16 mu m, suggesting a long-tailed non-Gaussian transverse beam profile. A q-Gaussian distribution function was suggested therein to reproduce this behavior. The spatial beam profile dynamics of a q-Gaussian laser beam propagating in relativistic plasma is investigated in this article. A non-paraxial theory is employed, taking into account nonlinearity via the relativistic decrease of the plasma frequency. We have studied analytically and numerically the dynamics of a relativistically guided beam and its dependence on the q-parameter. Numerical simulation results are shown to trace the dependence of the focusing length on the q-Gaussian profile.
Resumo:
We discuss a very effective numerical method for simulating fibre-bundle models with equal load-sharing and with local load-sharing. Particular attention is paid to the case of the local load-sharing model, in which the critical load x(c) is defined as the average load per fibre that causes the final complete failure. It is shown that x(c) --> 0 when the size of the system N --> infinity. We also show analytically that the power law of the burst size distribution, D(Delta) alpha Delta(-xi), is approximately correct. The exponent xi in the local load-sharing case is not universal, since it depends on the strength distribution as well on as the size of the system.
Resumo:
A critical load x(c) is introduced into the fiber-bundle model with local load-sharing. The critical load is defined as the average load per fiber that causes the final complete failure. It is shown that x(c) --> 0 when the size of the system N --> infinity. A power law for the burst-size distribution, D(DELTA) is-proportional-to DELTA(-xi) is approximately correct. The exponent xi is not universal, since it depends on the strength distribution as well as the size of the system.
Resumo:
The features of two popular models used to describe the observed response characteristics of typical oxygen optical sensors based on luminescence quenching are examined critically. The models are the 'two-site' and 'Gaussian distribution in natural lifetime, tau(o),' models. These models are used to characterise the response features of typical optical oxygen sensors; features which include: downward curving Stern-Volmer plots and increasingly non-first order luminescence decay kinetics with increasing partial pressures of oxygen, pO(2). Neither model appears able to unite these latter features, let alone the observed disparate array of response features exhibited by the myriad optical oxygen sensors reported in the literature, and still maintain any level of physical plausibility. A model based on a Gaussian distribution in quenching rate constant, k(q), is developed and, although flawed by a limited breadth in distribution, rho, does produce Stern-Volmer plots which would cover the range in curvature seen with real optical oxygen sensors. A new 'log-Gaussian distribution in tau(o) or k(q)' model is introduced which has the advantage over a Gaussian distribution model of placing no limitation on the value of rho. Work on a 'log-Gaussian distribution in tau(o)' model reveals that the Stern-Volmer quenching plots would show little degree in curvature, even at large rho values and the luminescence decays would become increasingly first order with increasing pO(2). In fact, with real optical oxygen sensors, the opposite is observed and thus the model appears of little value. In contrast, a 'log-Gaussian distribution in k(o)' model does produce the trends observed with real optical oxygen sensors; although it is technically restricted in use to those in which the kinetics of luminescence decay are good first order in the absence of oxygen. The latter model gives a good fit to the major response features of sensors which show the latter feature, most notably the [Ru(dpp)(3)(2+)(Ph4B-)(2)] in cellulose optical oxygen sensors. The scope of a log-Gaussian model for further expansion and, therefore, application to optical oxygen sensors, by combining both a log-Gaussian distribution in k(o) with one in tau(o) is briefly discussed.
Resumo:
The bacterium Coxiella burnetii, which has a wide host range, causes Q fever. Infection with C burnetii can cause abortions, stillbirth, and the delivery of weak offspring in ruminants. Coxiella burnetii infection is zoonotic, and in human beings it can cause chronic, potentially fatal disease. Real-time polymerase chain reaction (PCR) is increasingly being used to detect the organism and to aid in diagnosis both in human and animal cases. Many different real-time PCR methods, which target different genes, have been described. To assess the comparability of the C. burnetii real-time PCR assays in use in different European laboratories, a panel of nucleic acid extracts was dispatched to 7 separate testing centers. The testing centers included laboratories from both human and animal health agencies. Each laboratory tested the samples using their in-house real-time PCR methods. The results of this comparison show that the most common target gene for real-time PCR assays is the IS1111 repeat element that is present in multiple copies in the C. burnetii genome. Many laboratories also use additional real-time PCR tests that target single-copy genes. The results of the current study demonstrate that the assays in use in the different laboratories are comparable, with general agreement of results for the panel of samples.
Resumo:
Human cases of Q fever appear to be common in Northern Ireland compared to the rest of the British Isles. The purpose of this study was to describe the seroepidemiology of Coxiella burnetii infection in cattle in Northern Ireland in terms of seroprevalence and determinants of infection. A total of 5182 animals (from a stratified systematic random sample of 273 herds) were tested with a commercial C. burnetii phase 2 IgG ELISA. A total of 6.2% of animals and 48.4% of herds tested positively. Results from a multilevel logistic regression model indicated that the odds of cattle being infected with Q fever increased with age, Friesian breed, being from large herds and from dairy herds. Large dairy herd animal prevalence was 12.5% compared to 2.1% for small beef herds. Preliminary seroprevalence in sheep (12.3%), goats (9.3%), pigs (0%) rats (9.7%) and mice (3.2%) using indirect immunofluorescence is reported.
Resumo:
Despite the widespread prevalence of infection with Coxiella burnetii, there have been few large population-based studies examining the epidemiology of this infection. The aim of this study was to examine the distribution and determinants of C. burnetii past infection in Northern Ireland (NI). Coxiella burnetii phase II specific IgG antibodies were measured by enzyme-linked immunosorbent assay in stored serum from 2394 randomly selected subjects, aged 12-64, who had participated in population-based surveys of cardiovascular risk factors performed in 1986 and 1987. The overall prevalence of C. burnetii antibody positivity was 12.8%. The prevalence of sero-positivity was slightly higher in males than that in females (14.3% versus 11.2%, P = 0.02). Sero-positivity was low in children (