128 resultados para POSITIVE-IONS


Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report on the absolute calibration of a microchannel plate (MCP) detector, used in conjunction with a Thomson parabola spectrometer. The calibration delivers the relation between a registered count numbers in the CCD camera (on which the MCP phosphor screen is imaged) and the number of ions incident on MCP. The particle response of the MCP is evaluated for positive, negative, and neutral particles at energies below 1 MeV. As the response of MCP depends on the energy and the species of the ions, the calibration is fundamental for the correct interpretation of the experimental results. The calibration method and arrangement exploits the unique emission symmetry of a specific source of fast ions and atoms driven by a high power laser.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent years there have been many studies of multiple ionization of closed shell rare gas atoms by intense laser fields. Until now no similar work has been done in the study of more diverse targets such as negative ions where low binding energies and strong electron correlations could yield distinctive behaviour. We present the first results of ionization of more than one electron from a range of atomic negative ions by intense laser pulses. Although these pulses are long by modern standards, and tend to produce sequential ionization in atoms, the positive ion yields from the negative ions do not depend predictably on the ionization potentials. This suggests that there may, intriguingly, be an alternative mechanism enhancing double ionization at low intensities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Somatostatin-14 elicits negative inotropic and chronotropic actions in atrial myocardium. Less is known about the effects of somatostatin-14 in ventricular myocardium. The direct contractile effects of somatostatin-14 were assessed using ventricular cardiomyocytes isolated from the hearts of adult rats. Cells were stimulated at 0.5 Hz with CaCl2 (2 mM) under basal conditions and in the presence of the -adrenoceptor agonist, isoprenaline (1 nM), or the selective inhibitor of the transient outward current (Ito), 4-aminopyridine (500 M). Somatostatin-14 did not alter basal contractile response but it did inhibit (IC50 13 nM) the response to isoprenaline (1 nM). In the presence of 4-aminopyridine (500 M), somatostatin-14 stimulated a positive contractile response (EC50 118 fM) that was attenuated markedly by diltiazem (100 nM). These data indicate that somatostatin-14 exerts dual effects directly in rat ventricular cardiomyocytes: (1) a negative contractile effect, observed in the presence of isoprenaline (1 nM), coupled to activation of Ito; and (2) a previously unreported and very potent positive contractile effect, unmasked by 4-aminopyridine (500 M), coupled to the influx of calcium ions via L-type calcium channels. The greater potency of somatostatin-14 for producing the positive contractile effect indicates that the peptide may exert a predominantly stimulatory influence on the resting contractility of ventricular myocardium in vivo, whereas the negative contractile effect, observed at much higher concentrations, could indicate that localized elevations in the concentration of the peptide may serve as a negative regulatory influence to limit the detrimental effects of excessive stimulation of cardiomyocyte contractility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Highly charged ions have been used to study the sputtering of positive molecular fragments from mercaptoundecanoic acid and dodecanethiol self-assembled monolayers on gold surfaces. The samples were bombarded with Arq+ (42n+, and Cn+1O2H2n + 1+ from mercaptoundecanoic and H+, CnH2n+, and Cn+1H2n + 3+ from dodecanethiol. The proton yields were increased with larger charge state q of the highly charged ion (HCI) in both samples, scaling as qgamma, with gamma~5. The charge state dependence is discussed in terms of electron transfer to the HCI. The final yield of protons depends on molecular functional group characteristics, orientation on the surface, and reneutralization phenomena.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The nonlinear propagation of amplitude-modulated electrostatic wavepackets in an electron-positron-ion (e-p-i) plasma is considered, by employing a two-fluid plasma model. Considering propagation parallel to the external magnetic field, two distinct electrostatic modes are obtained, namely a quasi-thermal acoustic-like lower mode and a Langmuir-like optic-type upper one. These results equally apply in warm pair ion ( e. g. fullerene) plasmas contaminated by a small fraction of stationary ions ( or dust), in agreement with experimental observations and theoretical predictions in pair plasmas. Considering small yet weakly nonlinear deviations from equilibrium, and adopting a multiple-scales perturbation technique, the basic set of model equations is reduced to a nonlinear Schrodinger (NLS) equation for the slowly varying electric field perturbation amplitude. The analysis reveals that the lower ( acoustic) mode is mostly stable for large wavelengths, and may propagate in the form of a dark-type envelope soliton ( a void) modulating a carrier wavepacket, while the upper linear mode is intrinsically unstable, and thus favours the formation of bright-type envelope soliton ( pulse) modulated wavepackets. The stability ( instability) range for the acoustic ( Langmuir-like optic) mode shifts to larger wavenumbers as the positive-to-negative ion temperature ( density) ratio increases. These results may be of relevance in astrophysical contexts, where e-p-i plasmas are encountered, and may also serve as prediction of the behaviour of doped ( or dust-contaminated) fullerene plasmas, in the laboratory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

GC-MS data on veterinary drug residues in bovine urine are used for controlling the illegal practice of fattening cattle. According to current detection criteria, peak patterns of preferably four ions should agree within 10 or 20% from a corresponding standard pattern. These criteria are rigid, rather arbitrary and do not match daily practice. A new model, based on multivariate modeling of log peak abundance ratios, provides a theoretical basis for the identification of analytes and optimizes the balance between the avoidance of false positives and false negatives. The performance of the model is demonstrated on data provided by five laboratories, each supplying GC-MS measurements on the detection of clenbuterol, dienestrol and 19 beta-nortestosterone in urine. The proposed model shows a better performance than confirmation by using the current criteria and provides a statistical basis for inspection criteria in terms of error probabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose an effective Hamiltonian approach to investigate decoherence of a quantum system in a non-Markovian reservoir, naturally imposing the complete positivity on the reduced dynamics of the system. The formalism is based on the notion of an effective reservoir, i.e., certain collective degrees of freedom in the reservoir that are responsible for the decoherence. As examples for completely positive decoherence, we present three typical decoherence processes for a qubit such as dephasing, depolarizing, and amplitude damping. The effects of the non-Markovian decoherence are compared to the Markovian decoherence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine whether diagnostic triage by general practitioners (GPs) or rheumatology nurses (RNs) can improve the positive predictive value of referrals to early arthritis clinics (EACs).

Methods: Four GPs and two RNs were trained in the assessment of early in?ammatory arthritis (IA) by four visits to an EAC supervised by hospital rheumatologists. Patients referred to one of three EACs were recruited for study and assessed independently by a GP, an RN and one of six rheumatologists. Each assessor was asked to record their clinical ?ndings and whether they considered the patient to have IA. Each was then asked to judge the appropriateness of the referral according to predetermined guidelines. The rheumatologists had been shown previously to have a satisfactory level of agreement in the assessment of IA.

Results: Ninety-six patients were approached and all consented to take part in the study. In 49 cases (51%), the rheumatologist judged that the patient had IA and that the referral was appropriate. The assessments of GPs and RNs were compared with those of the rheumatologists. Levels of agreement were measured using the kappa value, where 1.0 represents total unanimity. The kappa value was
0.77 for the GPs when compared with the rheumatologists and 0.79 for the RNs. Signi?cant stiffness in the morning or after rest and objective joint swelling were the most important clinical features enabling the GPs and RNs to discriminate between IA and non-IA conditions.

Conclusion: Diagnostic triage by GPs or RNs improved the positive predictive value of referrals to an EAC with a degree of accuracy approaching that of a group of experienced rheumatologists.