23 resultados para Measuring method
Resumo:
Capillary-based systems for measuring the input impedance of musical wind instruments were first developed in the mid-20th century and remain in widespread use today. In this paper, the basic principles and assumptions underpinning the design of such systems are examined. Inexpensive modifications to a capillary-based impedance measurement set-up made possible due to advances in computing and data acquisition technology are discussed. The modified set-up is able to measure both impedance magnitude and impedance phase even though it only contains one microphone. In addition, a method of calibration is described that results in a significant improvement in accuracy when measuring high impedance objects on the modified capillary-based system. The method involves carrying out calibration measurements on two different objects whose impedances are well-known theoretically. The benefits of performing two calibration measurements (as opposed to the one calibration measurement that has been traditionally used) are demonstrated experimentally through input impedance measurements on two test objects and a Boosey and Hawkes oboe. © S. Hirzel Verlag · EAA.
Resumo:
Glaucoma is characterized by a typical appearance of the optic disc and peripheral visual field loss. However, diagnosis may be challenging even for an experienced clinician due to wide variability among normal and glaucomatous eyes. Standard automated perimetry is routinely used to establish the diagnosis of glaucoma. However, there is evidence that substantial retinal ganglion cell damage may occur in glaucoma before visual field defects are seen. The introduction of newer imaging devices such as confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography for measuring structural changes in the optic nerve head and retinal nerve fiber layer seems promising for early detection of glaucoma. New functional tests may also help in the diagnosis. However, there is no evidence that a single measurement is superior to the others and a combination of tests may be needed for detecting early damage in glaucoma. © 2010 Expert Reviews Ltd.
Resumo:
A highly sensitive broad specificity monoclonal antibody was produced and characterised for microcystin detection through the development of a rapid surface plasmon resonance (SPR) optical biosensor based immunoassay. The antibody displayed the following cross-reactivity: MC-LR 100%; MC-RR 108%; MC-YR 68%; MC-LA 69%; MC-LW 71%; MC-LF 68%; and Nodularin 94%. Microcystin-LR was covalently attached to a CM5 chip and with the monoclonal antibody was employed in a competitive 4min injection assay to detect total microcystins in water samples below the WHO recommended limit (1µg/L). A 'total microcystin' level was determined by measuring free and intracellular concentrations in cyanobacterial culture samples as this toxin is an endotoxin. Glass bead beating was used to lyse the cells as a rapid extraction procedure. This method was validated according to European Commission Decision 96/23/EC criteria. The method was proven to measure intracellular microcystin levels, the main source of the toxin, which often goes undetected by other analytical procedures and is advantageous in that it can be used for the monitoring of blooms to provide an early warning of toxicity. It was shown to be repeatable and reproducible, with recoveries from spiked samples ranging from 74 to 123%, and had % CVs below 10% for intra-assay analysis and 15% for inter-assay analysis. The detection capability of the assay was calculated as 0.5ng/mL for extracellular toxins and 0.05ng/mL for intracellular microcystins. A comparison of the SPR method with LC-MS/MS was achieved by testing six Microcystis aeruginosa cultures and this study yielded a correlation R(2) value of 0.9989.
Resumo:
We propose a feasible experimental scheme to direct measure heat and work in cold atomic setups. The method is based on a recent proposal which shows that work is a positive operator valued measure (POVM). In the present contribution, we demonstrate that the interaction between the atoms and the light polarization of a probe laser allows us to implement such POVM. In this way the work done on or extracted from the atoms after a given process is encoded in the light quadrature that can be measured with a standard homodyne detection. The protocol allows one to verify fluctuation theorems and study properties of the non-unitary dynamics of a given thermodynamic process.
Resumo:
Poverty means more than having a low income and includes exclusion from a minimally accepted way of life. It is now common practice in Europe to measure progress against poverty in terms of low income, material deprivation rates and some combination of both. This makes material deprivation indicators, and their selection, highly significant in its own right. The ‘consensual poverty’ approach is to identify deprivation items which a majority of the population agree constitute life’s basic necessities, accepting that these items will need revised over time to reflect social change. Traditionally, this has been carried out in the UK through specialised poverty surveys using a Sort Card (SC) technique.
Based on analysis of a 2012 omnibus survey, and discussions with three interviewers, this article examines how perception of necessities is affected by mode of administration – SC and Computer Assisted Personal Interviewing (CAPI). More CAPI respondents scored deprivation items necessary. Greatest disparities are in material items where 25 out of 32 items were significantly higher via CAPI. Closer agreement is found in social participation with 3 out of 14 activities significantly different. Consensus is higher on children’s material deprivation.
We consider influencing variables which could account for the disparities and believe that the SC method produces a more considered response. However, in light of technological advances, we question how long the SC method will remain socially acceptable. This paper concludes that the CAPI method can be easily modified without compromising the benefits of the SC method in capturing thoughtful responses.
Resumo:
The macrosystem refers to the overarching patterns that influence behavior at each level of the social ecology (Bronfenbrenner, 1977), making it a necessary component for assessing human development in contexts of political violence. This article proposes a method for systematically measuring the macrosystem in Northern Ireland that allows for a subnational analysis, multiple time units, and indicators of both low-level violence and positive relations. Articles were randomly chosen for each weekday in 2006-2011 from two prominent Northern Irish newspapers and coded according to their reflection of positive relations and political tensions between Catholics and Protestants. The newspaper data were then compared to existing macro-level measurements in Northern Ireland. We found that the newspaper data provided a more nuanced understanding of fluctuations in intergroup relations than the corresponding measures. This has practical implications for peacebuilding and advances our methods for assessing the impact of macro-level processes on individual development.
Resumo:
An assessment of the sustainability of the Irish economy has been carried out using three methodologies, enabling comparison and evaluation of the advantages and disadvantages of each, and potential synergies among them. The three measures chosen were economy-wide Material Flow Analysis (MFA), environmentally extended input-output (EE-IO) analysis and the Ecological Footprint (EF). The research aims to assess the sustainability of the Irish economy using these methods and to draw conclusions on their effectiveness in policy making both individually and in combination. A theoretical description discusses the methods and their respective advantages and disadvantages and sets out a rationale for their combined application. The application of the methods in combination has provided insights into measuring the sustainability of a national economy and generated new knowledge on the collective application of these methods. The limitations of the research are acknowledged and opportunities to address these and build on and extend the research are identified. Building on previous research, it is concluded that a complete picture of sustainability cannot be provided by a single method and/or indicator.
Resumo:
Introduction
Evaluating quality of palliative day services is essential for assessing care across diverse settings, and for monitoring quality improvement approaches.
Aim
To develop a set of quality indicators for assessment of all aspects (structure, process and outcome) of care in palliative day services.
Methods
Using a modified version of the RAND/UCLA appropriateness method (Fitch et al., 2001), a multidisciplinary panel of 16 experts independently completed a survey rating the appropriateness of 182 potential quality indicators previously identified during a systematic evidence review. Panel members then attended a one day, face-to-face meeting where indicators were discussed and subsequently re-rated. Panel members were also asked to rate the feasibility and necessity of measuring each indicator.
Results
71 indicators classified as inappropriate during the survey were removed based on median appropriateness ratings and level of agreement. Following the panel discussions, a further 60 were removed based on appropriateness and feasibility ratings, level of agreement and assessment of necessity. Themes identified during the panel discussion and findings of the evidence review were used to translate the remaining 51 indicators into a final set of 27.
Conclusion
The final indicator set included information on rationale and supporting evidence, methods of assessment, risk adjustment, and recommended performance levels. Further implementation work will test the suitability of this ‘toolkit’ for measurement and benchmarking. The final indicator set provides the basis for standardised assessment of quality across services, including care delivered in community and primary care settings.
Reference
• Fitch K, Bernstein SJ, Aguilar MD, et al. The RAND/UCLA Appropriateness Method User’s Manual. Santa Monica, CA: RAND Corporation; 2001. http://www.rand.org/pubs/monograph_reports/MR1269