31 resultados para Maximal arc
Performance of Cognitive Radio Networks with Maximal Ratio Combining over Correlated Rayleigh Fading
Resumo:
Purpose: The aim of this work was to determine if volumetric modulated arc therapy (VMAT) plans, created for constant dose-rate (cdrVMAT) delivery are a viable alternative to step and shoot five-field intensity modulated radiation therapy (IMRT). Materials and methods: The cdrVMAT plans, inverse planned on a treatment planning system with no solution to account for couch top or rails, were created for delivery on a linear accelerator with no variable dose rate control system. A series of five-field IMRT and cdrVMAT plans were created using dual partial arcs (gantry rotating between 260° and 100°) with 4° control points for ten prostate patients with the average rectal constraint incrementally increased. Pareto fronts were compared for the planning target volume homogeneity and average rectal dose between the two techniques for each patient. Also investigated were tumour control probability and normal tissue complication probability values for each technique. The delivery parameters [monitor units (MU) and time] and delivery accuracy of the IMRT and VMAT plans were also compared. Results: Pareto fronts showed that the dual partial arc plans were superior to the five-field IMRT plans, particularly for the clinically acceptable plans where average rectal doses were less for rotational plans (p = 0·009) with no statistical difference in target homogeneity. The cdrVMAT plans had significantly more MU (p = 0·005) but the average delivery time was significantly less than the IMRT plans by 42%. All clinically acceptable cdrVMAT plans were accurate in their delivery (gamma 99·2 ± 1·1%, 3%3 mm criteria). Conclusions Accurate delivery of dual partial arc cdrVMAT avoiding the couch top and rails has been demonstrated.
Resumo:
The fluid immobile High Field Strength Elements (HFSE) Nb and Ta can be used to distinguish between the effects of variable extents of melting and prior source depletion of the Tongan sub-arc mantle. Melting of spinel Iherzolite beneath the Lau Basin back-arc spreading centres has the ability to fractionate Nb from Ta due to the greater compatibility of the latter in clinopyroxene. The identified spatial variation in plate velocities and separation of melt extraction zones, combined with extremely depleted lavas make Tonga an ideal setting in which to test models for arc melt generation and the role of back-arc magmatism. We present new data acquired by laser ablation-ICPMS of fused sample glasses produced without the use of a melt fluxing agent. The results show an arc trend towards strongly sub-chondritic Nb/Ta (
Resumo:
Tofua volcano is situated midway along the Tonga oceanic arc and has undergone two phases of ignimbrite-forming activity. The eruptive products are almost entirely basaltic andesites (52 center dot 5-57 wt % SiO2) with the exception of a volumetrically minor pre-caldera dacite. The suite displays a strong tholeiitic trend with K2O <1 wt %. Phenocryst assemblages typically comprise plagioclase + clinopyroxene +/- orthopyroxene with microlites of Ti-magnetite. Olivine (Fo(83-88)) is rare and believed to be dominantly antecrystic. An increase in the extent and frequency of reverse zoning in phenocrysts, sieve-textured plagioclase and the occurrence of antecrystic phases in post-caldera lavas record a shift to dynamic conditions, allowing the interaction of magma batches that were previously distinct. Pyroxene thermobarometry suggests crystallization at 950-1200 degrees C and 0 center dot 8-1 center dot 8 kbar. Volatile measurements of glassy melt inclusions indicate a maximum H2O content of 4 center dot 16 wt % H2O, and CO2-H2O saturation curves indicate that crystallization occurred at two levels, at depths of 4-5 center dot 5 km and 1 center dot 5-2 center dot 5 km. Major and trace element models suggest that the compositions of the majority of the samples represent a differentiation trend whereby the dacite was produced by 65% fractional crystallization of the most primitive basaltic andesite. Trace element models suggest that the sub-arc mantle source is the residuum of depleted Indian mid-ocean ridge basalt mantle (IDMM-1% melt), whereas radiogenic isotope data imply addition of 0 center dot 2% average Tongan sediment melt and a fluid component derived from the subducted altered Pacific oceanic crust. A horizontal array on the U-Th equiline diagram and Ra excesses of up to 500% suggest fluid addition to the mantle wedge within the last few thousand years. Time-integrated (Ra-226/Th-230) vs Sr/Th and Ba/Th fractionation models imply differentiation timescales of up to 4500 years for the dacitic magma compositions at Tofua.
Resumo:
Fonualei is unusual amongst subaerial volcanoes in the Tonga arc because it has erupted dacitic vesicular lavas, tuffs and phreomagmatic deposits for the last 165 years. The total volume of dacite may approach 5 km(3) and overlies basal basaltic andesite and andesite lavas that are constrained to be less than a few millennia in age. All of the products are crystal-poor and formed from relatively low-viscosity magmas inferred to have had temperatures of 1100-1000 degrees C, 2-4 wt % H2O and oxygen fugacities 1-2 log units above the quartz-fayalite-magnetite buffer. Major and trace element data, along with Sr-Nd-Pb and U-Th-Ra isotope data, are used to assess competing models for the origin of the dacites. Positive correlations between Sc and Zr and Sr rule out evolution of the within-dacite compositional array by closed-system crystal fractionation of a single magma batch. An origin by partial melting of lower crustal amphibolites cannot reproduce these data trends or, arguably, any of the dacites either. Instead, we develop a model in which the dacites reflect mixing between two dacitic magmas, each the product of fractional crystallization of basaltic andesite magmas formed by different degrees of partial melting. Mixing was efficient because the two magmas had similar temperatures and viscosities. This is inferred to have occurred at shallow (2-6 km) depths beneath the volcano. U-Th-Ra disequilibria in the basaltic andesite and andesite indicate that the parental magmas had fluids added to their mantle source regions less than 8 kyr ago and that fractionation to the dacitic compositions took less than a few millennia. The 165 year eruption period for the dacites implies that mixing occurred on a similar timescale, possibly during ascent in conduits. The composition of the dacites renders them unsuitable candidates as contributors to average continental crust.
Resumo:
New U-Th-Ra, major and trace element, and Sr-Nd-Pb isotope data are presented for young lavas from the New Britain and Western Bismarck arcs in Papua New Guinea. New Britain is an oceanic arc, whereas the latter is the site of an arc-continent collision. Building on a recent study of the Manus Basin, contrasts between the two arcs are used to evaluate the processes and timescales of magma generation accompanying arc-continent collision and possible slab detachment. All three suites share many attributes characteristic of arc lavas that can be ascribed to the addition of a regionally uniform subduction component derived from the subducting altered oceanic crust and sediment followed by dynamic melting of the modified mantle. However, the Western Bismarck arc lavas diverge from the Pb isotope mixing array formed by the New Britain and the Manus Basin lavas toward elevated Pb-208/Pb-204. We interpret this to reflect a second and subsequent addition of sediment melt at crustal depth during collision. U-238 and Ra-226 excesses are preserved in all of the lavas and are greatest in the Western Bismarck arc. High-Mg andesites with high Sr/Y ratios in the westernmost arc are attributed to recent shallow mantle flux melting at the slab edge. Data for two historical rhyolites are also presented. Although these rhyolites formed in quite different tectonic settings and display different geochemical and isotopic compositions, both formed from mafic parents within millennia.
Resumo:
The Fonualei Spreading Center affords an excellent opportunity to evaluate geochemical changes with increasing depth to the slab in the Lau back-arc basin. We present H2O and CO2 concentrations and Sr, Nd, Pb, Hf and U-Th-Ra isotope data for selected glasses as well as new Hf isotope data from boninites and seamounts to the north of the Tonga arc. The Pb and Hf isotope data are used to show that mantle flow is oriented to the southwest and that the tear in the northern end of the slab may not extend east as far as the boninite locality. Along the Fonualei Spreading Center, key geochemical parameters change smoothly with increasing distance from the arc front and increasing slab surface temperatures. The latter may range from 720 to 866 degrees C, based on decreasing H2O/Ce ratios. Consistent with experimental data, the geochemical trends are interpreted to reflect changes in the amount and composition of wet pelite melts or super-critical fluids and aqueous fluids derived from the slab. With one exception, all of the lavas preserve both U-238 excesses and Ra-226 excesses. We suggest that lavas from the Fonualei Spreading Center and Valu Fa Ridge are dominated by fluid-fluxed melting whereas those from the East and Central Lau Spreading Centers, where slab surface temperatures exceed similar to 850-900 degrees C, are largely derived through decompression. A similar observation is found for the Manus and East Scotia back-arc basins and may reflect the expiry of a key phase such as lawsonite in the subducted basaltic crust.
Resumo:
Background
]In modern radiotherapy, it is crucial to monitor the performance of all linac components including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method has been introduced in conjunction with an algorithm to investigate the stability of these systems during arc treatments with the aim of ensuring the accuracy of linac mechanical performance.
The Varian EPID sag, gantry sag, changes in source-to-detector distance (SDD), EPID and collimator skewness, EPID tilt, and the sag in MLC carriages as a result of linac rotation were separately investigated by acquisition of EPID images of a simple phantom comprised of 5 ball-bearings during arc delivery. A fast and robust software package was developed for automated analysis of image data. Twelve Varian linacs of different models were investigated.
The average EPID sag was within 1 mm for all tested linacs. All machines showed less than 1 mm gantry sag. Changes in SDD values were within 1.7 mm except for three linacs of one centre which were within 9 mm. Values of EPID skewness and tilt were negligible in all tested linacs. The maximum sag in MLC leaf bank assemblies was around 1 mm. The EPID sag showed a considerable improvement in TrueBeam linacs.
The methodology and software developed in this study provide a simple tool for effective investigation of the behaviour of linac components with gantry rotation. It is reproducible and accurate and can be easily performed as a routine test in clinics.
Resumo:
This paper is concerned with weak⁎ closed masa-bimodules generated by A(G)-invariant subspaces of VN(G). An annihilator formula is established, which is used to characterise the weak⁎ closed subspaces of B(L2(G)) which are invariant under both Schur multipliers and a canonical action of M(G) on B(L2(G)) via completely bounded maps. We study the special cases of extremal ideals with a given null set and, for a large class of groups, we establish a link between relative spectral synthesis and relative operator synthesis.
Resumo:
PURPOSE: To investigate the effects of using volumetric modulated arc therapy (VMAT) and/or voluntary moderate deep inspiration breath-hold (vmDIBH) in the radiation therapy (RT) of left-sided breast cancer including the regional lymph nodes.
MATERIALS AND METHODS: For 13 patients, four treatment combinations were compared; 3D-conformal RT (i.e., forward IMRT) in free-breathing 3D-CRT(FB), 3D-CRT(vmDIBH), 2 partial arcs VMAT(FB), and VMAT(vmDIBH). Prescribed dose was 42.56 Gy in 16 fractions. For 10 additional patients, 3D-CRT and VMAT in vmDIBH only were also compared.
RESULTS: Dose conformity, PTV coverage, ipsilateral and total lung doses were significantly better for VMAT plans compared to 3D-CRT. Mean heart dose (D(mean,heart)) reduction in 3D-CRT(vmDIBH) was between 0.9 and 8.6 Gy, depending on initial D(mean,heart) (in 3D-CRT(FB) plans). VMAT(vmDIBH) reduced the D(mean,heart) further when D(mean,heart) was still >3.2 Gy in 3D-CRT(vmDIBH). Mean contralateral breast dose was higher for VMAT plans (2.7 Gy) compared to 3DCRT plans (0.7 Gy).
CONCLUSIONS: VMAT and 3D-CRT(vmDIBH) significantly reduced heart dose for patients treated with locoregional RT of left-sided breast cancer. When Dmean,heart exceeded 3.2 Gy in 3D-CRT(vmDIBH) plans, VMAT(vmDIBH) resulted in a cumulative heart dose reduction. VMAT also provided better target coverage and reduced ipsilateral lung dose, at the expense of a small increase in the dose to the contralateral breast.
Resumo:
The Arc-Length Method is a solution procedure that enables a generic non-linear problem to pass limit points. Some examples are provided of mode-jumping problems solutions using a commercial nite element package, and other investigations are carried out on a simple structure of which the numerical solution can be compared with an analytical one. It is shown that Arc-Length Method is not reliable when bifurcations are present in the primary equilibrium path; also the presence of very sharp snap-backs or special boundary conditions may cause convergence diÆculty at limit points. An improvement to the predictor used in the incremental procedure is suggested, together with a reliable criteria for selecting either solution of the quadratic arc-length constraint. The gap that is sometimes observed between the experimantal load level of mode-jumping and its arc-length prediction is explained through an example.