152 resultados para Laser therapy of low intensity
Resumo:
Background: Persistent or recurrent macular-sparing subretinal fluid (SRF) can sometimes occur following scleral buckling procedures. Observation and reoperation have been used in the management of such cases. Demarcation laser therapy (DLT) has been used to treat macular-sparing retinal detachments in the context of cytomegalovirus retinitis and as primary treatment for selected rhegmatogenous retinal detachments. There are, however, scarce data in the literature regarding its use following primary scleral buckling procedures. The current study explores the use of DLT under the latter circumstances. Methods: The medical records of all consecutive patients with persistent SRF sparing the macula following primary rhegmatogenous retinal detachment repair using a scleral buckling procedure were retrospectively reviewed. Only those patients in whom the breaks were localised to the area of indentation and, thus, seemed to be well supported by the buckle were included. Demographics, clinical characteristics of the retinal detachment prior to scleral buckling, extension of the residual SRF observed postoperatively, details of the laser procedure, anatomical and functional outcomes and complications were evaluated. Results: Seven patients, all females, with a mean age of 47.9 years (range: 20-81) were included in the study. The retinal detachments were superior (n=3), inferior (n=3) and subtotal, affecting both superior and inferior retina (n=1). Scleral buckling procedures were used to treat the retinal detachments in all cases. Following demarcation laser therapy, the area of SRF remained stable in two patients, and flattened in four. In one patient, extension of SRF occurred requiring further surgery. Conclusions: Demarcation laser therapy appears to be a reasonable option in the management of patients with persistent or recurrent SRF sparing the macula following scleral buckling surgery. © Springer-Verlag 2006.
Resumo:
The two-dimensional laser-plasma-interaction hydrodynamic code POLLUX has been used to simulate the ablation of a magnesium target by a 30-ns, 248-nm KrF excimer laser at low laser fluences of ≤10 J cm2. This code, originally written for much higher laser intensities, has been recently extended to include a detailed description of the equation of state in order to treat changes of phase within the target material, and also includes a Thomas Fermi description of the electrons. The simulated temporal and spatial evolution of the plasma plume in the early phase of the expansion (≤100 ns) is compared with experimental interferometric measurements of electron density. The expansion dynamics are in good agreement, although the simulated electron number density is about 2.5 times higher than the experimental values.
Resumo:
OBJECTIVE: Assess efficacy and acceptability of reduced intensity constraint-induced movement therapy (CIMT) in children with cerebral palsy (CP).
METHODS: Single-subject research design and semi-structured interviews. Children (9-11y) with hemiplegia underwent five baseline assessments followed by two weeks CIMT. Six further assessments were performed during treatment and follow-up phases. The primary outcome was the Melbourne Assessment of Unilateral Upper Limb Function (MUUL). Quantitative data were analysed using standard single-subject methods and qualitative data by thematic analysis.
RESULTS: Four of the seven participants demonstrated statistically significant improvements in MUUL (3-11%, p < .05). Two participants achieved significant improvements in active range of motion but strength and tone remained largely unchanged. Qualitative interviews highlighted limitations of the restraint, importance of family involvement, and coordination of treatment with education.
CONCLUSIONS: Reduced intensity CIMT may be effective for some children in this population; however it is not suitable for all children with hemiplegia.
Resumo:
Sputtered silicon is investigated as a bonding layer for transfer of pre-processed silicon layers to various insulating substrates. Although the material appears suitable for low temperature processing, previous work has shown that gas trapped in the pores of the sputtered material is released at temperatures above 350 degrees C and further increases of temperature lead to destruction of any bonded interface. Pre-annealing at 1000 degrees C before bonding drives out gas and/or seals the surface, but for device applications where processing temperatures must be kept below about 300 degrees C, this technique cannot be used. In the current work, we have investigated the effect of excimer laser-annealing to heat the sputtered silicon surface to high temperature whilst minimising heating of the underlying substrate. Temperature profile simulations are presented and the results of RBS, TEM and AFM used to characterise the annealed layers. The results verify that gases are present in the sub-surface layers and suggest that while sealing of the surface is important for suppression of the out-diffusion of gases, immediate surface gas removal may also play a role. The laser-annealing technique appears to be an effective method of treating sputtered silicon, yielding a low roughness surface suitable for wafer bonding, thermal splitting and layer transfer.
Resumo:
It has been shown that a femtosecond plasma of cluster targets is an almost isotropic source of fast ions and, hence, can be used to obtain ionographic images with a wide field of view. The spatial resolution of the resulting ionographic images is no worse than 600 nm, which corresponds to a uniquely high value of about 105 of the ratio of the field of view to the resolution. The use of 100–300-keV ion fluxes ensures the sensitivity of the method to the sample thickness of no worse than 100 nm even for samples consisting of light chemical elements (C, H). The proposed method can be used to obtain images of low-contrast biological objects, thin films, membranes, and other nanostructured objects.
Resumo:
Optical emission spectra from a low-pressure Ar plasma were studied with high spatial resolution. It has been shown that the intensity ratios of Ar lines excited through metastable levels to those excited directly from the ground state are sensitive to the shape of electron energy distribution function. From these measurements, important information on the spatial variation of plasma parameters can be obtained. (C) 1999 American Institute of Physics. [S0003-6951(99)01629-0].
Resumo:
Aim: To evaluate and summarize the current evidence on the effectiveness of complementary and alternative medicine for the management of low back pain and/or pelvic pain in pregnancy.
Background: International research demonstrates that 25-30% of women use complementary and alternative medicine to manage low back and pelvic pain in pregnancy without robust evidence demonstrating its effectiveness.
Design: A systematic review of randomized controlled trials to determine the effectiveness of complementary and alternative medicine for low back and/or pelvic pain in pregnancy.
Data Sources: Cochrane library (1898-2013), PubMed (1996-2013), MEDLINE (1946-2013), AMED (1985-2013), Embase (1974-2013), Cinahl (1937-2013), Index to Thesis (1716-2013) and Ethos (1914-2013).
Review Methods: Selected studies were written in English, randomized controlled trials, a group 1 or 2 therapy and reported pain reduction as an outcome measure. Study quality was reviewed using Risk of Bias and evidence strength the Cochrane Grading of Recommendations and Development Evaluation Tool.
Results: Eight studies were selected for full review. Two acupuncture studies with low risk of bias showed both clinically important changes and statistically significant results. There was evidence of effectiveness for osteopathy and chiropractic. However, osteopathy and chiropractic studies scored high for risk of bias. Strength of the evidence across studies was very low.
Conclusion: There is limited evidence supporting the use of general CAM for managing pregnancy-related low back and/or pelvic pain. However, the restricted availability of high-quality studies, combined with the very low evidence strength, makes it impossible to make evidence-based recommendations for practice.
Resumo:
An innovative bioadhesive patch intended primarily as a vulval drug delivery system and, specifically, as a means to deliver photosensitisers, or their prodrugs, for photodynamic purposes is described. The patch was formulated with a copolymer of methyl vinyl ether and maleic anhydride (PMVE/MA) as a bioadhesive matrix and poly(vinyl chloride) as a drug-impervious backing layer. Adhesive strength to neonate porcine skin, as a model substrate, was evaluated using peel and tensile testing measurements. Acceptabilities of non-drug loaded patches were appraised using human volunteers and visual-analogue scoring devices. An optimal formulation, with water uptake and peel strengths appropriate for vulval drug delivery, was cast from a 20% (w/w) PMVE/MA solution and adhered with a strength of approximately 1.7 N cm-2. Patient evaluation demonstrated comfort and firm attachment for up to 4 h in mobile patients. Aminolevulinic acid, a commonly used photosensitiser, was formulated into the candidate formulation and applied to vulval intraepithelial neoplastic lesions. Fluorescence under ultraviolet illumination revealed protoporphyrin synthesis. The patch achieves the extended application times obligatory in topical photodynamic therapy of vulval lesions, thereby contributing to potential methods for the eradication of neoplastic lesions in the lower female reproductive tract.