49 resultados para Fatigue jacket offshore wind turbine
Resumo:
In the coming decade installed offshore wind capacity is expected to expand rapidly. This will be both technically and economically challenging. Precise wind resource assessment is one of the more imminent challenges. It is more difficult to assess wind power offshore than onshore due to the paucity of representative wind speed data. Offshore site-specific data is less accessible and is far more costly to collect. However, offshore wind speed data collected from sources such as wave buoys, remote sensing from satellites, national weather ships, and coastal meteorological stations and met masts on barges and platforms may be extrapolated to assess offshore wind power. This study attempts to determine the usefulness of pre-existing offshore wind speed measurements in resource assessment, and presents the results of wind resource estimation in the Atlantic Ocean and in the Irish Sea using data from two offshore meteorological buoys
Resumo:
At least 34 % of the United Kingdom’s power must come from renewable energy sources to meet planned European Union targets in 2030. Wind power will provide the majority of this renewable electricity with an estimated 36 GW offshore and 21 GW onshore. The success of the Crown Estate’s leasing rounds 1 and 2 in offshore wind has meant the United Kingdom is now one of the world leaders in offshore wind power development. Leasing round 3 will see offshore wind in the United Kingdom surpass 36 GW of installed capacity. This is a significant increase from the current installed offshore wind capacity of 3.6 GW. This research investigates the power system performance of offshore wind power in the United Kingdom in 2030.
Resumo:
This paper explores the nature of public acceptance of wind farms by investigating the discourses of support and objection to a proposed offshore scheme. It reviews research into opposition to wind farms, noting previous criticisms that this has tended to provide descriptive rather than explanatory insights and as a result, has not effectively informed the policy debate. One explanation is that much of this research has been conceived within an unreflective positivist research frame, which is inadequate in dealing with the subjectivity and value-basis of public acceptance of wind farm development. The paper then takes a case study of an offshore wind farm proposal in Northern Ireland and applies Q-Methodology to identify the dominant discourse of support and objection. It is argued that this provides new insights into the nature of wind farm conflicts, points to a number or recommendations for policy functions of an example of how this methodology can act as a potential bridge between positivist and post-positivist approaches to policy analysis.
Resumo:
This paper outlines the use of phasor measurement unit (PMU) records to validate models of fixed speed induction generator (FSIG)-based wind farms during frequency transients. Wind turbine manufacturers usually create their own proprietary models which they can supply to power system utilities for stability studies, subject to confidentiality agreements. However, it is desirable to confirm the accuracy of supplied models with measurements from the particular installation, in order to assess their validity under real field conditions. This is prudent due to possible changes in control algorithms and design retrofits, not accurately reflected or omitted in the supplied model. One important aspect of such models, especially for smaller power systems with limited inertia, is their accuracy during system frequency transients. This paper, therefore, assesses the accuracy of FSIG models with regard to frequency stability, and hence validates a subset of the model dynamics. Such models can then be used with confidence to assess wider system stability implications. The measured and simulated response of a wind farm using doubly fed induction generator (DFIG) technology is also assessed.
Resumo:
The doubly-fed induction generator (DFIG) now represents the dominant technology in wind turbine design. One consequence of this is limited damping and inertial response during transient grid disturbances. A dasiadecoupledpsila strategy is therefore proposed to operate the DFIG grid-side converter (GSC) as a static synchronous compensator (STATCOM) during a fault, supporting the local voltage, while the DFIG operates as a fixed-speed induction generator (FSIG) providing an inertial response. The modeling aspects of the decoupled control strategy, the selection of protection control settings, the significance of the fault location and operation at sub- and super-synchronous speeds are analyzed in detail. In addition, a case study is developed to validate the proposed strategy under different wind penetrations levels. The simulations show that suitable configuration of the decoupled strategy can be deployed to improve system voltage stability and inertial response for a range of scenarios, especially at high wind penetration. The conclusions are placed in context of the practical limitations of the technology employed and the system conditions.
Resumo:
This paper proposes a method for wind turbine mode identification using the multivariable output error statespace (MOESP) identification algorithm. The paper incorporates a fast moving window QR decomposition and propagator method from array signal processing, yielding a moving window subspace identification algorithm. The algorithm assumes that the system order is known as a priori and remains constant during identification. For the purpose of extracting modal information for turbines modelled as a linear parameter varying (LPV) system, the algorithm is applicable since a nonlinear system can be approximated as a piecewise time invariant system in consecutive data windows. The algorithm is exemplified using numerical simulations which show that the moving window algorithm can track the modal information. The paper also demonstrates that the low computational burden of the algorithm, compared to conventional batch subspace identification, has significant implications for online implementation.
Resumo:
The inertia of fixed-speed wind turbine generators (WTGs) helps to mitigate under-frequency transients, promotes fault ride-through and damps inter-area oscillations. It is therefore important to quantify this inertia. The authors use measured wind farm responses during under-frequency transients to provide this information. They discuss the extent of the data and the criteria used to select certain events for further analysis. The estimation of WTG inertia is based on a induction generator model. The basis of the model will be described. The manner in which the model is applied to estimate the inertia from the measured data is then explained. Finally, the implications of the results for power system operation are assessed.
Resumo:
In this study, a constant suction technique for controlling boundary layer separation at low Reynolds numbers was designed and tested. This was later implemented on small wind turbines. Small wind turbines need to operate in low wind speeds, that is, in low Reynolds number regimes – typically in the range 104–105. Airfoils are prone to boundary layer separation in these conditions, leading to a substantial drop in aerodynamic performance of the blades. Under these conditions turbines will have reduced energy output. This paper presents experimental results of applying surface-suction over the suction-surface of airfoils for controlling boundary layer separation. The Reynolds numbers for the experiments are kept in the range 8×104–5×105. The air over the surface of the airfoil is drawn into the airfoil through a slit. It is found that the lift coefficient of the airfoils increases and the drag reduces. Based on the improved airfoil characteristics, an analysis of increase in Coefficient of Power (CP), versus input power for a small wind turbine blade with constant suction is presented.
Resumo:
The small signal stability of interconnected power systems is one of the important aspects that need to be investigated since the oscillations caused by this kind of instability have caused many incidents. With the increasing penetration of wind power in the power system, particularly doubly fed induction generator (DFIG), the impact on the power system small signal stability performance should be fully investigated. Because the DFIG wind turbine integration is through a fast action converter and associated control, it does not inherently participate in the electromechanical small signal oscillation. However, it influences the small signal stability by impacting active power flow paths in the network and replacing synchronous generators that have power system stabilizer (PSS). In this paper, the IEEE 39 bus test system has been used in the analysis. Furthermore, four study cases and several operation scenarios have been conducted and analysed. The selective eigenvalue Arnoldi/lanczos's method is used to obtain the system eigenvalue in the range of frequency from 0.2 Hz to 2 Hz which is related to electromechanical oscillations. Results show that the integration of DFIG wind turbines in a system during several study cases and operation scenarios give different influence on small signal stability performance.
Resumo:
The power system of the future will have a hierarchical structure created by layers of system control from via regional high-voltage transmission through to medium and low-voltage distribution. Each level will have generation sources such as large-scale offshore wind, wave, solar thermal, nuclear directly connected to this Supergrid and high levels of embedded generation, connected to the medium-voltage distribution system. It is expected that the fuel portfolio will be dominated by offshore wind in Northern Europe and PV in Southern Europe. The strategies required to manage the coordination of supply-side variability with demand-side variability will include large scale interconnection, demand side management, load aggregation and storage in the concept of the Supergrid combined with the Smart Grid. The design challenge associated with this will not only include control topology, data acquisition, analysis and communications technologies, but also the selection of fuel portfolio at a macro level. This paper quantifies the amount of demand side management, storage and so-called ‘back-up generation’ needed to support an 80% renewable energy portfolio in Europe by 2050.
Resumo:
Globally the amount of installed terrestrial wind power both onshore and offshore has grown rapidly over the last twenty years. Most large onshore and offshore wind turbines are designed to harvest winds within the atmospheric boundary layer, which can be vary variable due to terrain and weather effects. The height of the neutral atmospheric boundary layer is estimated at above 1300m. A relatively new concept is to harvest more consistent wind conditions above the atmospheric boundary layer using high altitude wind harvesting devices such as tethered kites, air foils and dirigible rotors. This paper presents a techno-economic feasibility study of high altitude wind power in Northern Ireland. First this research involved a state of the art review of the resource and the technologies proposed for high altitude wind power. Next the techno-economic analysis involving four steps is presented. In step one, the potential of high altitude wind power in Northern Ireland using online datasets (e.g. Earth System Research Laboratory) is estimated. In step two a map for easier visualisation of geographical limitations (e.g. airports, areas of scenic beauty, flight paths, military training areas, settlements etc.) that could impact on high altitude wind power is developed. In step three the actual feasible resource available is recalculated using the visualisation map to determine the ‘optimal’ high altitude wind power locations in Northern Ireland. In the last step four the list of equipment, resources and budget needed to build a demonstrator is provided in the form of a concise techno-economic appraisal using the findings of the previous three steps.
Resumo:
The results in this paper are based on a data set containing system demand, wind generation and CO2 emission between Jan 2010 and Sep 2013. The data was recorded at 15 minute intervals and reflects the macroscopic operation of the Republic of Ireland's electrical grid. The data was analyzed by investigating how daily wind generation effected daily CO2 emission across multiple days with equivalent daily demand. A figure for wind turbine efficiency was determined by dividing the CO2 mitigation potential of wind power by the CO2 intensity of the grid; both in units of Tonnes of CO2 per MWh. The yearly wind power efficiency appears to have increased by 5.6% per year, now standing around 90%. Over the four years significant regularity was observed in the profiles of wind turbine efficiency against daily demand. It appears that the efficiency profile has moved in recent years so that maximum efficiency coincides with most frequent demand.
Resumo:
Social acceptance for wind turbines is variable, providing a challenge to the implementation of this energy source. Psychological research could contribute to the science of climate change. Here we focus on the emotional responses to the visual impact of wind turbines on the landscape, a factor which dominates attitudes towards this technology. Participants in the laboratory viewed images of turbines and other constructions (churches, pylons and power-plants) against rural scenes, and provided psychophysiological and self-report measures of their emotional reactions. We hypothesised that the emotional response to wind turbines would be more negative and intense than to control objects, and that this difference would be accentuated for turbine opponents. As predicted, the psychophysiological response to turbines was stronger than the response to churches, but did not differ from that of other industrial constructions. In contrast with predictions, turbines were rated as less aversive and more calming compared with other industrial constructions, and equivalent to churches. Supporters and non-supporters did not differ significantly from each other. We discuss how a methodology using photo manipulations and emotional self-assessments can help estimate the emotional reaction to the visual impact on the landscape at the planning stage for new wind turbine applications.