112 resultados para Documentary series
Resumo:
An analysis of a modified series-L/parallel-tuned Class-E power amplifier is presented, which includes the effects that a shunt capacitance placed across the switching device will have on Class-E behaviour. In the original series L/parallel-tuned topology in which the output transistor capacitance is not inherently included in the circuit, zero-current switching (ZCS) and zero-current derivative switching (ZCDS) conditions should be applied to obtain optimum Class-E operation. On the other hand, when the output transistor capacitance is incorporated in the circuit, i.e. in the modified series-L/parallel-tuned topology, the ZCS and ZCDS would not give optimum operation and therefore zero-voltage-switching (ZVS) and zero-voltage-derivative switching (ZVDS) conditions should be applied instead. In the modified series-L/parallel-tuned Class-E configuration, the output-device inductance and the output-device output capacitance, both of which can significantly affect the amplifier's performance at microwave frequencies, furnish part, if not all, of the series inductance L and the shunt capacitance COUT, respectively. Further, when compared with the classic shunt-C/series-tuned topology, the proposed Class-E configuration offers some advantages in terms of 44% higher maximum operating frequency (fMAX) and 4% higher power-output capability (PMAX). As in the classic topology, the fMAX of the proposed amplifier circuit is reached when the output-device output capacitance furnishes all of the capacitance COUT, for a given combination of frequency, output power and DC supply voltage. It is also shown that numerical simulations agree well with theoretical predictions.
Resumo:
In this brief, we propose a new Class-E frequency multiplier based on the recently introduced Series-L/Parallel-Tuned Class-E amplifier. The proposed circuit produces even-order output harmonics. Unlike previously reported solutions the proposed circuit can operate under 50% duty ratio which minimizes the conduction losses. The circuit also offers the possibility for increased maximum operating frequency, reduced peak switch voltage, higher load resistance and inherent bond wire absorption; all potentially useful in monolithic microwave integrated circuit implementations. In addition, the circuit topology suggested large transistors with high output capacitances can be deployed. Theoretical design equations are given and the predictions made using these are shown to agree with harmonic balance circuit simulation results.
Resumo:
The impact that the transmission-line load-network has on the performance of the recently introduced series-L/parallel-tuned Class-E amplifier and the classic shunt-C/series-tuned configuration when compared to optimally derived lumped load networks is discussed. In addition an improved load topology which facilitates harmonic suppression of up to 5 order as required for maximum Class-E efficiency as well as load resistance transformation and a design procedure involving the use of Kuroda's identity and Richard's transformation enable a distributed synthesis process which dispenses with the need for iterative tuning as previously required in order to achieve optimum Class-E operation. © 2005 IEEE.
Resumo:
The five room temperature ionic liquids: 1-alkyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([CnMIM][N(Tf)(2)], n = 2, 4, 8, 10) and n-hexyltriethylammonium bis(trifluoromethylsulfonyl)imide ([N-6222][N(Tf)(2)]) were investigated as solvents in which to study the electrochemical oxidation of N,N,N',N'-tetramethyl-para-phenylenediamine (TMPD) and N,N,N',N'-tetrabutyl-paraphenylenediamine (TBPD), using 20 mul micro-samples under vacuum conditions. The effect of dissolved atmospheric gases on the accessible electrochemical window was probed and determined to be less significant than seen previously for ionic liquids containing alternative anions. Chronoamperometric transients recorded at a microdisk electrode were analysed via a process of non-linear curve fitting to yield values for the diffusion coefficients of the electroactive species without requiring a knowledge of their initial concentration. Comparison of experimental and simulated cyclic voltammetry was then employed to corroborate these results and allow diffusion coefficients for the electrogenerated species to be estimated. The diffusion coefficients obtained for the neutral compounds in the five ionic liquids via this analysis were, in units of 10(-11) m(2) s(-1), 2.62, 1.87, 1.12, 1.13 and 0.70 for TMPD. and 1.23, 0.80, 0.40, 0.52 and 0.24 for TBPD (listed using the same order for the ionic liquids as stated above). The most significant consequence of changing the cationic component of the ionic liquid was found to be its effect on the solvent viscosity; the diffusion coefficient of each species was found to be approximately inversely proportional to viscosity across the series of ionic liquids, in accordance with Walden's rule. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The electrochemical reduction of oxygen is reported in four room temperature ionic liquids (RTILs) based on quaternary alkyl -onium cations and heavily fluorinated anions in which the central atom is either nitrogen or phosphorus. Data were collected using cyclic voltammetry and potential step chronoamperometry at gold, platinum, and glassy carbon disk electrodes of micrometer dimension under water-free conditions at a controlled temperature. Analysis via fitting, to appropriate theoretical equations was then carried out to obtain kinetic and thermodynamic information pertaining to the electrochemical processes observed. In the quaternary ammonium electrolytes, reduction of oxygen was found to occur reversibly to give stable superoxide, in an analogous manner to that seen in conventional aprotic solvents such as dimethyl sufoxide and acetonitrile. The most significant difference is in the relative rate of diffusion; the diffusion coefficients of oxygen in the RTILs are an order of magnitude lower than in common organic solvents, and for superoxide these values are reduced by a further factor of 10. In the quaternary phosphonium ionic liquids, however, more complex voltammetry is observed, akin to that expected for the reduction of oxygen in acidified organic media. This is shown to be consistent with the occurrence of a proton abstraction reaction between the electrogenerated superoxide and quaternary alkyl phosphonium cations following the initial electron transfer.
Resumo:
A novel 3rd-order compact E-plane ridge waveguide filter is presented. Miniaturization is achieved upon introducing a configuration of parallel-coupled E-plane ridge waveguide resonators. Furthermore, the proposed filter allows for transmission zeros at finite frequencies. Fabrication simplicity and mass producibility of standard E-plane filters is maintained. The numerical and experimental results are presented to validate the proposed configuration. A miniaturisation factor of 2 and very sharp upper cutoff are achieved. 2005 Wiley Periodicals, Inc.
Resumo:
An analysis of the operation of a series-L/parallel-tuned class-E amplifier and its equivalence to the classic shunt-C/series-tuned class-E amplifier are presented. The first reported closed form design equations for the series-L/parallel-tuned topology operating under ideal switching conditions are given. Furthermore, a design procedure is introduced that allows the effect that nonzero switch resistance has on amplifier performance efficiency to be accounted for. The technique developed allows optimal circuit components to be found for a given device series resistance. For a relatively high value of switching device ON series resistance of 4O, drain efficiency of around 66% for the series-L/parallel-tuned topology, and 73% for the shunt-C/series-tuned topology appear to be the theoretical limits. At lower switching device series resistance levels, the efficiency performance of each type are similar, but the series-L/parallel-tuned topology offers some advantages in terms of its potential for MMIC realisation. Theoretical analysis is confirmed by numerical simulation for a 500mW (27dBm), 10% bandwidth, 5 V series-L/parallel-tuned, then, shunt-C/series-tuned class E power amplifier, operating at 2.5 GHz, and excellent agreement between theory and simulation results is achieved. The theoretical work presented in the paper should facilitate the design of high-efficiency switched amplifiers at frequencies commensurate with the needs of modern mobile wireless applications in the microwave frequency range, where intrinsically low-output-capacitance MMIC switching devices such as pHEMTs are to be used.
Resumo:
Objectives: Methicillin-resistant Staphylococcus aureus (MRSA) is a major nosocomial pathogen worldwide. A wide range of factors have been suggested to influence the spread of MRSA. The objective of this study was to evaluate the effect of antimicrobial drug use and infection control practices on nosocomial MRSA incidence in a 426-bed general teaching hospital in Northern Ireland.
Methods: The present research involved the retrospective collection of monthly data on the usage of antibiotics and on infection control practices within the hospital over a 5 year period (January 2000–December 2004). A multivariate ARIMA (time-series analysis) model was built to relate MRSA incidence with antibiotic use and infection control practices.
Results: Analysis of the 5 year data set showed that temporal variations in MRSA incidence followed temporal variations in the use of fluoroquinolones, third-generation cephalosporins, macrolides and amoxicillin/clavulanic acid (coefficients = 0.005, 0.03, 0.002 and 0.003, respectively, with various time lags). Temporal relationships were also observed between MRSA incidence and infection control practices, i.e. the number of patients actively screened for MRSA (coefficient = -0.007), the use of alcohol-impregnated wipes (coefficient = -0.0003) and the bulk orders of alcohol-based handrub (coefficients = -0.04 and -0.08), with increased infection control activity being associated with decreased MRSA incidence, and between MRSA incidence and the number of new patients admitted with MRSA (coefficient = 0.22). The model explained 78.4% of the variance in the monthly incidence of MRSA.
Conclusions: The results of this study confirm the value of infection control policies as well as suggest the usefulness of restricting the use of certain antimicrobial classes to control MRSA.