171 resultados para Diagnostic specimens
Resumo:
We report on a study comparing absolute K-alpha yield from Ti foils measured with a calibrated system of an X-ray CCD coupled to a curved LiF Von-Hamos crystal spectrometer to the difference in the signals measured simultaneously with two similar photodiodes fitted with two different filters. Our data indicate that a combination of photodiodes with different filters could be developed into an alternative and inexpensive diagnostic for monitoring single shot pulsed emission in a narrow band of X-ray region.
Resumo:
Background. Invasive Candida infection among nonneutropenic, critically ill adults is a clinical problem that has received increasing attention in recent years. Poor performance of extant diagnostic modalities has promoted risk-based, preemptive prescribing in view of the poor outcomes associated with inadequate or delayed antifungal therapy; this risks unnecessary overtreatment. A rapid, reliable diagnostic test could have a substantial impact on therapeutic practice in this patient population.
Methods. Three TaqMan-based real-time polymerase chain reaction assays were developed that are capable of detecting the main medically important Candida species, categorized according to the likelihood of fluconazole susceptibility. Assay 1 detected Candida albicans, Candida parapsilosis, Candida tropicalis, and Candida dubliniensis. Assays 2 and 3 detected Candida glabrata and Candida krusei, respectively. The clinical performance of these assays, applied to serum, was evaluated in a prospective trial of nonneutropenic adults in a single intensive care unit.
Results. In all, 527 specimens were obtained from 157 participants. All 3 assays were run in parallel for each specimen; they could be completed within 1 working day. Of these, 23 specimens were obtained from 23 participants categorized as having proven Candida infection at the time of sampling. If a single episode of Candida famata candidemia was excluded, the estimated clinical sensitivity, specificity, and positive and negative predictive values of the assays in this trial were 90.9%, 100%, 100% and 99.8%, respectively.
Conclusions. These data suggest that the described assays perform well in this population for enhancing the diagnosis of candidemia. The extent to which they may affect clinical outcomes, prescribing practice, and cost-effectiveness of care remains to be ascertained.
Resumo:
Phase resolved optical emission spectroscopy (PROES) bears considerable potential for diagnostics of RF discharges that give detailed insight of spatial and temporal variations of excitation processes. Based on phase and space resolved measurements of the population dynamics of excited states several diagnostic techniques have been developed. Results for a hydrogen capacitively coupled RF (CCRF) discharge are discussed as an example. The gas temperature, the degree of dissociation and the temporally and spatially resolved electron energy distribution function (EEDF) of energetic electrons (>12eV) are measured. Furthermore, the pulsed electron impact excitation during the field reversal phase, typical for hydrogen CCRF discharges, is exploited for measurements of atomic and molecular data like lifetimes of excited states, coefficients for radiationless collisional de-excitation (quenching coefficients), and cascading processes from higher electronic states.
Resumo:
Three plasma diagnostic methods, tunable infrared diode laser absorption spectroscopy, optical emission spectroscopy and microwave interferometry have been used to monitor concentrations of transient and stable molecules, CH3, CH4, C2H2, C2H6, and of electrons in capacitively coupled CH4-H-2-Ar radiofrequency (RF) plasmas (f(RF) = 13.56 MHz, p = 100 Pa, phi (total)= 66 sccm) for various discharge power values (P = 10-100 W) and gas mixtures. The degree of dissociation of the methane precursor varied between 3% and 60%. The methyl radical concentration was found to be in the order of 10(12) molecules cm(-3) and the electron concentration in the order of loll cm(-3). The methyl radical concentration and the concentrations of the stable C-2 hydrocarbons, C2H2 and C2H6, produced in the plasma, increased with discharge power. The fragmentation rates of the methane precursor and conversion rates to the measured C-2 hydrocarbons were estimated in dependence on discharge power. Radial distributions of the electron and methyl radical concentrations, and of the gas temperature were measured for the first time simultaneously in the plasma region between the discharge electrodes. The measurements allow us to draw qualitative conclusions on the main chemical processes and the plasma chemical reaction paths.