30 resultados para Cr-EDTA
Resumo:
Aims. In this paper we report on calculations of energy levels, radiative rates, oscillator strengths, line strengths, and effective collision strengths for transitions among the lowest 362 levels of the (1s22s22p6) 3s23p5, 3s3p6, 3s23p43d, 3s3p53d, 3s23p33d2, 3s3p43d2, 3p63d, and 3s23p44 configurations of Cr viii. Methods. The general-purpose relativistic atomic structure package (grasp) and flexible atomic code (fac) are adopted for the calculations. Results. Radiative rates, oscillator strengths, and line strengths are reported for all electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2), and magnetic quadrupole (M2) transitions among the 362 levels. Comparisons are made with earlier available results and the accuracy of the data is assessed. Additionally, lifetimes for all 362 levels are listed, although comparisons with other theoretical results are limited to only a few levels. Our energy levels are estimated to be accurate to better than 3% (within 0.4 Ryd), whereas results for other parameters are probably accurate to better than 20%. Finally, electron impact collision strengths and excitation rates are computed for all transitions over a wide energy (temperature) range. For these calculations, FAC is adopted and results in the form of effective collision strengths are reported over a wide temperature range of 105.0−106.6 K.
Resumo:
The advantage of using an available and abundant residual biomass, such as lignin, as a raw material for activated carbons is that it provides additional economical interest to the technical studies. In the current investigation, a more complete understanding of adsorption of Cr(VI) from aqueous systems onto H PO -acid activated lignin has been achieved via microcolumns, which were operated under various process conditions. The practice of using microcolumn is appropriate for defining the adsorption parameters and for screening a large number of potential adsorbents. The effects of solution pH (2-8), initial metal ion concentration (0.483-1.981 mmol·L ), flow rate (1.0-3.1 cm ·min ), ionic strength (0.01-0.30 mmol·L ) and adsorbent mass (0.11-0.465 g) on Cr(VI) adsorption were studied by assessing the microcolumn breakthrough curve. The microcolumn data were fitted by the Thomas model, the modified Dose model and the BDST model. As expected, the adsorption capacity increased with initial Cr(VI) concentration. High linear flow rates, pH values and ionic strength led to early breakthrough of Cr(VI). The model constants obtained in this study can be used for the design of pilot scale adsorption process. © 2012 Chemical Industry and Engineering Society of China (CIESC) and Chemical Industry Press (CIP).
Resumo:
Samples of suspended, floodplain and channel bed sediment have been used to examine downstream changes in ediment-associated contaminant transport and storage in contrasting rivers in Yorkshire, UK. The concentrations of hosphorus, chromium and selected PCBs associated with sediment in the River Aire and its main tributary, the River Calder, which drain an urbanized and industrialized catchment, are considerably higher than those in the relatively unpolluted River Swale, which drains an agricultural catchment. Concentrations of sediment-associated contaminants in the Aire/Calder system increase downstream, reflecting the location of urban and industrial areas in the middle and lower reaches, and the location of point source inputs, such as sewage treatment works. The ontaminant concentrations associated with floodplain and channel bed sediment in the Rivers Aire and Calder are high, particularly in the lower reaches. This, combined with measurements of sediment storage on the floodplain and channel bed, indicate that significant storage of sediment-associated contaminants occurs in the Rivers Aire and Calder.
Resumo:
The search for materials or systems exhibiting a high magnetic saturation has been of longstanding importance. It has been suggested that increased saturation could be achieved by coupling a transition metal via a spacer to a rare earth. We report Gd/Cr/Fe70Co30 multilayer stacks and find reduced yet modulating magnetic moment as a function of Cr thickness. Through a micro structural analysis the lowered moment is indicated by the nucleation of the ultrathin Gd films into an fcc phase. We discuss the possible solution in terms of quasi-perfect lattice match seed material to promote growth of hcp Gd.
Resumo:
Potentially toxic elements (PTEs) including nickel and chromium are often present in soils overlying basalt at concentrations above regulatory guidance values due to the presence of these elements in underlying geology. Oral bioaccessibility testing allows the risk posed by PTEs to human health to be assessed; however, bioaccessibility is controlled by factors including mineralogy, particle size, solid-phase speciation and encapsulation. X-ray diffraction was used to characterise the mineralogy of 12 soil samples overlying Palaeogene basalt lavas in Northern Ireland, and non-specific sequential extraction coupled with chemometric analysis was used to determine the distribution of elements amongst soil components in 3 of these samples. The data obtained were related to total concentration and oral bioaccessible concentration to determine whether a relationship exists between the overall concentrations of PTEs, their bioaccessibility and the soils mineralogy and geochemistry. Gastric phase bioaccessible fraction (BAF %) ranged from 0.4 to 5.4 % for chromium in soils overlying basalt and bioaccessible and total chromium concentrations are positively correlated. In contrast, the range of gastric phase BAF for nickel was greater (1.4–43.8 %), while no significant correlation was observed between bioaccessible and total nickel concentrations. However, nickel BAF was inversely correlated with total concentration. Solid-phase fractionation information showed that bioaccessible nickel was associated with calcium carbonate, aluminium oxide, iron oxide and clay-related components, while bioaccessible chromium was associated with clay-related components. This suggests that weathering significantly affects nickel bioaccessibility, but does not have the same effect on the bioaccessibility of chromium.
Resumo:
Tea waste (TW) and Date pits (DP) were investigated for their potential to remove toxic Cr(VI) ions from aqueous solution. Investigations showed that the majority of the bound Cr(VI) ions were reduced to Cr(III) after biosorption at acidic conditions. The electrons for the reduction of Cr(VI) may have been donated from the TW and DP biomasses. The experimental data obtained for Cr(VI)-TW and Cr(VI)-DP at different solution temperatures indicate a multilayer type biosorption, which explains why the Sips isotherm accurately represents the experimental data obtained in this study. The Sips maximum biosorption capacities of Cr(VI) onto TW and DP were 5.768 and 3.199 mmol/g at 333 K, respectively, which is comparatively superior to most other low-cost biomaterials. Fourier transform infrared spectroscopic analysis of the metal loaded biosorbents confirmed the participation of -COOH, -NH and O-CH groups in the reduction and complexation of chromium. Thermodynamic parameters demonstrated that the biosorption of Cr(VI) onto TW and DP biomass was endothermic, spontaneous and feasible at 303-333 K. The results evidently indicated that tea waste and date pits would be suitable biosorbents for Cr(VI) in wastewater under specific conditions.
Resumo:
Stoichiometrically equivalent concentrations of ethylenediaminetetraacetate, EDTA, and of related chelating anions increase the adsorption of ca. millimolar concentrations heavy metal aqua-ions on amorphous precipitates of aluminium(III) or iron(III) hydroxide and, although higher concentrations decrease the adsorption, poly-EDTA, a polyelectrolyte containing EDTA functional groups, shows no such decrease.
Resumo:
Biosorption of Cr(VI) onto date pit biomass has been investigated via kinetic studies as functions of initial Cr(VI) concentration, solution temperature and date pit particle size. Kinetic experiments indicated that chromate ions accumulate onto the date pits and then reduce to less toxic Cr(III) compounds. The López-García, Escudero and Park Cr(VI) biosorption kinetic models, which take into consideration the direct reduction, the passivation process and the follow-on decrease of the active surface area of reaction, were applied to the kinetic data. The models represented the experimental data accurately at low Cr(VI) concentration (0.480 mM) and small particle size (0.11–0.22 mm) at which the Cr(VI) was completely removed from the aqueous solution and completely reduced to Cr(III) after 420 min. Date pit biomass thus offers a green chemical process for the remediation of chromium from wastewater. This investigation will help researchers employ the adsorption-coupled reduction of Cr(VI) models and simplify their application to kinetic experimental data.
Resumo:
Hydrous cerium oxide (HCO) was synthesized by intercalation of solutions of cerium(III) nitrate and sodium hydroxide and evaluated as an adsorbent for the removal of hexavalent chromium from aqueous solutions. Simple batch experiments and a 25 factorial experimental design were employed to screen the variables affecting Cr(VI) removal efficiency. The effects of the process variables; solution pH, initial Cr(VI) concentration, temperature, adsorbent dose and ionic strength were examined. Using the experimental results, a linear mathematical model representing the influence of the different variables and their interactions was obtained. Analysis of variance (ANOVA) demonstrated that Cr(VI) adsorption significantly increases with decreased solution pH, initial concentration and amount of adsorbent used (dose), but slightly decreased with an increase in temperature and ionic strength. The optimization study indicates 99% as the maximum removal at pH 2, 20 °C, 1.923 mM of metal concentration and a sorbent dose of 4 g/dm3. At these optimal conditions, Langmuir, Freundlich and Redlich–Peterson isotherm models were obtained. The maximum adsorption capacity of Cr(VI) adsorbed by HCO was 0.828 mmol/g, calculated by the Langmuir isotherm model. Desorption of chromium indicated that the HCO adsorbent can be regenerated using NaOH solution 0.1 M (up to 85%). The adsorption interactions between the surface sites of HCO and the Cr(VI) ions were found to be a combined effect of both anion exchange and surface complexation with the formation of an inner-sphere complex.
Resumo:
We report calculations of energy levels, radiative rates and electron impact excitation cross sections and rates for transitions in He-like Ti XXI, V XXII, Cr XXIII and Mn XXIV. grasp (general-purpose relativistic atomic structure package) is adopted for calculating energy levels and radiative rates. For determining the collision strengths and subsequently the excitation rates, the Dirac atomic R-matrix code (darc) is used. Oscillator strengths, radiative rates and line strengths are reported for all E1, E2, M1 and M2 transitions among the lowest 49 levels of each ion. Additionally, theoretical lifetimes are listed for all the 49 levels of the above four ions. Collision strengths are averaged over a Maxwellian velocity distribution and the effective collision strengths obtained listed over a wide temperature range up to 10 7.5K. Comparisons are made with similar data obtained using the flexible atomic code (fac) to highlight the importance of resonances, included in calculations with darc, in the determination of effective collision strengths. Discrepancies between the collision strengths from darc and fac, in particular for forbidden transitions, are also discussed. Finally, discrepancies between the present results for effective collision strengths with the darc code and earlier semi-relativistic R-matrix data are noted over a wide range of electron temperatures for many transitions in all ions.
Resumo:
A comparison of collision strengths and effective collision strengths has been undertaken for the Cr II ion based on the model of Wasson et al [2010 A & A. 524 A35]. Calculations have been completed using the Breit-Pauli, RMATRX II and DARC suites of codes.