181 resultados para Controlled release, HIV microbicide, dapivirine, maraviroc, vaginal ring


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new vaginal ring technology, the insert vaginal ring (InVR), is presented. The InVR overcomes the current shortfall of conventional vaginal rings (VRs) that are generally ineffectual for the delivery of hydrophilic and/or macromolecular actives, including peptides, proteins and antibodies, due to their poor permeation characteristics in the hydrophobic polymeric elastomers from which VRs are usually fabricated. Release of the model protein BSA from a variety of insert matrices for the InVR is demonstrated, including modified silicone rods, directly compressed tablets and lyophilised gels, which collectively provided controlled release profiles from several hours to beyond 4 weeks. Furthermore, the InVR was shown to deliver over 1 mg of the monoclonal antibody 2F5 from a single device, offering a potential means of protecting women against the transmission of HIV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study describes the preclinical development of a matrix-type silicone elastomer vaginal ring device designed to provide controlled release of UC781, a non-nucleoside re- verse transcriptase inhibitor. Testing of both human- and macaque-sized rings in a sink condition in vitro release model demonstrated continuous UC781 release in quantities consid- ered sufficient to maintain vaginal fluid concentrations at levels 82–860-fold higher than the in vitro IC50 (2.0 to 10.4 nM) and therefore potentially protect against mucosal trans- mission of HIV. The 100-mg UC781 rings were well tolerated in pig-tailed macaques, did not induce local inflammation as determined by cytokine analysis and maintained median con- centrations in vaginal fluids of UC781 in the range of 0.27 to 5.18 mM during the course of the 28-day study. Analysis of residual UC781 content in rings after completion of both the in vitro release and macaque pharmacokinetic studies revealed that 57 and 5 mg of UC781 was released, respectively. The pharmacokinetic analysis of a 100-mg UC781 vaginal ring in pig-tailed macaques showed poor in vivo–in vitro correlation, attributed to the very poor solubility of UC781 in vaginal fluid and resulting in a dissolution-controlled drug release mecha- nism rather than the expected diffusion-controlled mechanism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background There is considerable interest in developing coitally indepen- dent, sustained release formulations for long-term administration of HIV microbicides. Vaginal ring devices are at the forefront of this formulation strategy. Methods Non-medicated silicone elastomer vaginal rings were prepared having a range of appropriate dimensions for testing vaginal ?t in pig- tailed and Chinese rhesus macaques. Cervicovaginal proin?ammatory markers were evaluated. Compression testing was performed to compare the relative ?exibility of various macaque and commercial human rings. Results All rings remained in place during the study period and no tissue irritation or signi?cant induction of cervicovaginal proin?ammatory mark- ers or signs of physical discomfort were observed during the 8-week study period. Conclusions Qualitative evaluation suggests that the 25 · 5-mm ring pro- vided optimal ?t in both macaque species. Based on the results presented here, low-consistency silicone elastomers do not cause irritation in maca-

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Vaginal ring devices are being actively developed for controlled delivery of HIV microbicides and as multi-purpose prevention technology (MPT) products combining hormonal contraception with prevention of HIV and other sexually transmitted diseases. Presently, there is no reliable method for monitoring user adherence in HIV vaginal ring trials; previous acceptability studies have included some type of participant self-reporting mechanism, which have often been unreliable. More objective, quantitative and accurate methods for assessing adherence are needed.
Methods: A silicone elastomer vaginal ring containing an encapsulated miniature temperature recording device has been developed that can capture and store real-time temperature data during the period of designated use. Devices were tested in both simulated vaginal environments and following vaginal placement in cynomolgus macaques. Various use protocols and data sampling rates were tested to simulate typical patient usage scenarios. Results: The temperature logging devices accurately recorded vaginal temperature in macaques, clearly showing the regular diurnal temperature cycle. When environmental temperature and vaginal temperature was significantly different, the device was able to accurately pinpoint the insertion and removal times. Based on the data collected it was possible to infer removal periods as short as 5 min when the external environmental temperature was 25 °C. Accuracy increased with data sampling rate. Conclusions: This work provides proof-of-concept for monitoring adherence using a vaginal ring device containing an encapsulated temperature logger. The addition of one or more active agents into the ring body is not anticipated to affect the temperature monitoring function. A clinical study to compare self- reported user adherence data with that obtained by the device would be highly informative.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Administration of biomacromolecular drugs in effective quantities from conventional vaginal rings is hampered by poor drug permeability in the polymers from which rings are commonly constructed. Here, we report the formulation development and testing of rod insert rings for sustained release of the candidate antiretroviral peptides T-1249 and JNJ54310516-AFP (JNJ peptide), both of which have potential as HIV microbicides. Rod inserts were prepared comprising antiviral peptides T-1249 or JNJ peptide in combination with a hydrophilic excipient (sodium chloride, sodium glutamate, lactose or zinc acetate) dispersed at different loadings within a medical grade silicone elastomer. The inserts were tested for weight change and swelling when immersed in simulated vaginal fluid (SVF). Dye migration into the inserts was also assessed visually over 28 days. In vitro release of T-1249 and JNJ peptide from rings containing various insert types was tested. Weight change and degree of swelling of rods immersed in SVF was dependent on the type and concentration of excipient present. The rods displayed the following rank order in terms of weight change: sodium glutamate > zinc acetate ≈ sodium chloride > lactose. The weight change and degree of swelling of the inserts did not correlate with the level of dye uptake observed. In vitro release of T-1249 was improved through addition of lactose, sodium chloride and sodium glutamate, while release of JNJ peptide was improved through addition of sodium chloride or sodium glutamate. Sustained release of hydrophobic peptides can be achieved using a rod insert ring design formulated to include a hydrophilic excipient. Release rates were dependent upon the type of excipient used. The degree of release improvement with different inserts partially reflects their ability to imbibe surrounding fluid and swell in aqueous environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vaginal rings (VRs) are flexible, torus-shaped, polymeric devices designed to sustain delivery of pharmaceutical drugs to the vagina for clinical benefit. Following first report in a 1970 patent application, several steroid-releasing VR products have since been marketed for use in hormone replacement therapy and contraception. Since 2002, there has been growing interest in the use of VR technology for delivery of drugs that can reduce the risk of sexual acquisition of human immunodeficiency virus type 1 (HIV-1), the causative agent of acquired immunodeficiency syndrome (AIDS). Although no vaginally-administered product has yet been approved for HIV reduction/prevention, extensive research efforts are continuing and a number of VR devices offering sustained release of so-called ‘HIV microbicide’ compounds are currently being evaluated in late-stage clinical studies. This review article provides an overview of the published scientific literature within this important field of research, focusing primarily on articles published within peer-reviewed journal publications. Many important aspects of microbicide-releasing VR technology are discussed, with a particular emphasis on the technological, manufacturing and clinical challenges that have emerged in recent years.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Vaginal ring devices are being developed to provide sustained release of HIV microbicides. To date, only limited pharmacokinetic data is available from animal or human studies. Here we report the effect of Depo-Provera (DP) pre- treatment, commonly used to thin the vaginal epithelium in challenge experiments, on the pharmacokinetic profile of CMPD167 (a small molecule CCR5 co-receptor antagonist) in rhesus macaques following vaginal ring administration.

METHODS: A single 400mg CMPD167 silicone elastomer vaginal ring was inserted into each of twelve female rhesus macaques. Six macaques were treated with (DP) 30 days before ring placement; the other six macaques were untreated. Blood, vaginal fluid and vaginal biopsies were collected prior to and at various times during 28 days of ring placement and assayed for CMPD167 levels by HPLC. Rings were assayed for residual CMPD167 at the end of the study and the calculated amount of CMPD167 released in vivo compared with in vitro release data.

RESULTS: Vaginal fluid, plasma and tissue levels of CMPD167 were detectable throughout ring placement. Significant differences were observed in mean daily vaginal fluid levels between the DP-treated (16–56 mcg/mL) and untreated groups (48–181 mcg/mL). Plasma CMPD167 levels were significantly higher peaking at 4 ng/mL and maintaining levels of 1–2 nM throughout the 14 days of testing in animals pre-treated with DP compared to non DP-treated macaques (<1 ng/mL maintained). Tissue levels were varied between 2–10 g/mL CMPD167 with no significant difference between the DP-treated and untreated macaques.

CONCLUSIONS: The study demonstrates that clinically relevant, and possibly protective doses of CMPD167 are released in the vaginal vault of rhesus macaques from vaginal rings through 28 days duration. DP is known to induce vaginal epithelial thinning and lower vaginal fluid levels, which accounts for the increased plasma levels of CMPD167. In contrast, macaques not treated with DP had minimal absorption into plasma compartments and significantly higher levels of CMPD167 in the vagina, similar to those previously shown to be protective against vaginal challenge.