48 resultados para Comparison between methods of analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate virtual reality as a laparoscopic training device in helping surgeons to automate to the “fulcrum effect” by comparing it to time-matched training programs using randomly alternating images (ie, y-axis inverted and normal laparoscopic) and normal laparoscopic viewing conditions.

Methods: Twenty-four participants (16 females and 8 males), were randomly assigned to minimally invasive surgery virtual reality (MIST VR), randomly alternating (between y-axis inverted and normal laparoscopic images), and normal laparoscopic imaging condition. Participants were requested to perform a 2-minute laparoscopic cutting task before and after training.

Results: In the test trial participants who trained on the MIST VR performed significantly better than those in the normal laparoscopic and randomly alternating imaging conditions.

Conclusion: The results show that virtual reality training may provide faster skill acquisition with particular reference to automation of the fulcrum effect. MIST VR provides a new way of training laparoscopic psychomotor surgical skills.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dealing with uncertainty problems in intelligent systems has attracted a lot of attention in the AI community. Quite a few techniques have been proposed. Among them, the Dempster-Shafer theory of evidence (DS theory) has been widely appreciated. In DS theory, Dempster's combination rule plays a major role. However, it has been pointed out that the application domains of the rule are rather limited and the application of the theory sometimes gives unexpected results. We have previously explored the problem with Dempster's combination rule and proposed an alternative combination mechanism in generalized incidence calculus. In this paper we give a comprehensive comparison between generalized incidence calculus and the Dempster-Shafer theory of evidence. We first prove that these two theories have the same ability in representing evidence and combining DS-independent evidence. We then show that the new approach can deal with some dependent situations while Dempster's combination rule cannot. Various examples in the paper show the ways of using generalized incidence calculus in expert systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Immunoaffinity chromatography (IAC) and affinity chromatography (AC:) are widely used for extraction of drugs from biological samples. Fifteen column types were purchased from five different manufacturers and;their ability to bind specific drugs including beta-agonists and anabolic steroids over a range of analyte concentrations in fortified bovine urine samples was assessed. The performance data obtained from these columns were compared with columns produced in this laboratory (in house columns). The in house columns gave the highest recoveries, ranging from 92 to 100% at the 1 ng spiking concentration, for five of the seven analytes assessed. Forty percent (11 of 27) of all the commercial column assessments recorded recoveries of less than 50% even when the lowest spiking concentration was applied (1 ng). For one manufacturer, only one of seven different columns purchased delivered extraction efficiencies greater than 50%. The extraction efficiencies of the clenbuterol columns were the highest with all commercially prepared columns showing at least 50% binding of radiolabelled tracer. Recoveries of alpha-nortestosterone were the lowest. The variability of these products with respect to quality control requires constant monitoring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims. The core collapse supernova rate provides a strong lower limit for the star formation rate (SFR). Progress in using it as a cosmic SFR tracer requires some confidence that it is consistent with more conventional SFR diagnostics in the nearby Universe. This paper compares standard SFR measurements based on H alpha, far ultraviolet (FUV) and total infrared (TIR) galaxy luminosities with the observed core collapse supernova rate in the same galaxy sample. The comparison can be viewed from two perspectives. Firstly, by adopting an estimate of the minimum stellar mass to produce a core collapse supernova one can determine a SFR from supernova numbers. Secondly, the radiative SFR can be assumed to be robust and then the supernova statistics provide a constrain on the minimum stellar mass for core collapse supernova progenitors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Increases in food production and the ever-present threat of food contamination from microbiological and chemical sources have led the food industry and regulators to pursue rapid, inexpensive methods of analysis to safeguard the health and safety of the consumer. Although sophisticated techniques such as chromatography and spectrometry provide more accurate and conclusive results, screening tests allow a much higher throughput of samples at a lower cost and with less operator training, so larger numbers of samples can be analysed. Biosensors combine a biological recognition element (enzyme, antibody, receptor) with a transducer to produce a measurable signal proportional to the extent of interaction between the recognition element and the analyte. The different uses of the biosensing instrumentation available today are extremely varied, with food analysis as an emerging and growing application. The advantages offered by biosensors over other screening methods such as radioimmunoassay, enzyme-linked immunosorbent assay, fluorescence immunoassay and luminescence immunoassay, with respect to food analysis, include automation, improved reproducibility, speed of analysis and real-time analysis. This article will provide a brief footing in history before reviewing the latest developments in biosensor applications for analysis of food contaminants (January 2007 to December 2010), focusing on the detection of pathogens, toxins, pesticides and veterinary drug residues by biosensors, with emphasis on articles showing data in food matrices. The main areas of development common to these groups of contaminants include multiplexing, the ability to simultaneously analyse a sample for more than one contaminant and portability. Biosensors currently have an important role in food safety; further advances in the technology, reagents and sample handling will surely reinforce this position.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The International Nusantara Stratification and Transport (INSTANT) program measured currents through multiple Indonesian Seas passages simultaneously over a three-year period (from January 2004 to December 2006). The Indonesian Seas region has presented numerous challenges for numerical modelers - the Indonesian Throughflow (ITF) must pass over shallow sills, into deep basins, and through narrow constrictions on its way from the Pacific to the Indian Ocean. As an important region in the global climate puzzle, a number of models have been used to try and best simulate this throughflow. In an attempt to validate our model, we present a comparison between the transports calculated from our model and those calculated from the INSTANT in situ measurements at five passages within the Indonesian Seas (Labani Channel, Lifamatola Passage, Lombok Strait, Ornbai Strait, and Timor Passage). Our Princeton Ocean Model (POM) based regional Indonesian Seas model was originally developed to analyze the influence of bottom topography on the temperature and salinity distributions in the Indonesian seas region, to disclose the path of the South Pacific Water from the continuation of the New Guinea Coastal Current entering the region of interest up to the Lifamatola Passage, and to assess the role of the pressure head in driving the ITF and in determining its total transport. Previous studies found that this model reasonably represents the general long-term flow (seasons) through this region. The INSTANT transports were compared to the results of this regional model over multiple timescales. Overall trends are somewhat represented but changes on timescales shorter than seasonal (three months) and longer than annual were not considered in our model. Normal velocities through each passage during every season are plotted. Daily volume transports and transport-weighted temperature and salinity are plotted and seasonal averages are tabulated.