49 resultados para Closure flexibility


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Domain states in PbZr(0.42)Ti(0.58)O3 single-crystal ferroelectric nanodots, formed on cooling through the Curie temperature, were imaged by transmission electron microscopy. In the majority of cases, 90o stripe domains were found to form into four distinct “bundles” or quadrants. Detailed analysis of the dipole orientations in the system was undertaken, using both dark-field imaging and an assumption that charged domain walls were energetically unfavorable in comparison to uncharged walls. On this basis, we conclude that the dipoles in these nanodots are arranged such that the resultant polarizations, associated with the four quadrant domain bundles, form into a closed loop. This “polarization closure” pattern is reminiscent of the flux-closure already commonly observed in soft ferromagnetic microdots but to date unseen in analogous ferroelectric dots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Naturally occurring boundaries between bundles of 90° stripe domains, which form in BaTiO3 lamellae on cooling through the Curie Temperature, have been characterized using both piezoresponse force microscopy (PFM) and scanning transmission electron microscopy (STEM). Detailed interpretation of the dipole configurations present at these boundaries (using data taken from PFM) shows that in the vast majority of cases they are composed of simple zigzag 180° domain walls. Topological information from STEM shows that occasionally domain bundle boundaries can support chains of dipole flux closure and quadrupole nanostructures, but these kinds of boundaries are comparatively rare; when such chains do exist, it is notable that singularities at the cores of the dipole
structures are avoided. The symmetry of the boundary shows that diads and centers of inversion exist at positions where core singularities should have been expected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: In ischemic retinopathies, the misdirection of reparative angiogenesis away from the hypoxic retina leads to pathologic neovascularization. Thus, therapeutic strategies that reverse this trend would be extremely beneficial. Nitric oxide (NO) produced by endothelial nitric oxide synthase (eNOS) is an important mediator of vascular endothelial growth factor (VEGF) function facilitating vascular growth and maturation. However, in addition to NO, eNOS can also produce superoxide (O), exacerbating pathology. Here, our aim was to investigate the effect of eNOS overexpression on vascular closure and subsequent recovery of the ischemic retina.

Methods: Mice overexpressing eNOS-GFP were subjected to oxygen-induced retinopathy (OIR) and changes in retinal vascularization quantified. Background angiogenic drive was assessed during vascular development and in aortic rings. NOS activity was measured by Griess assay or conversion of radiolabeled arginine to citrulline, nitrotyrosine (NT), and superoxide by immunolabeling and dihydroethidium fluorescence and VEGF by ELISA.

Results: In response to hyperoxia, enhanced eNOS expression led to increased NOS-derived superoxide and dysfunctional NO production, NT accumulation, and exacerbated vessel closure associated with tetrahydrobiopterin (BH) insufficiency. Despite worse vaso-obliteration, eNOS overexpression resulted in elevated hypoxia-induced angiogenic drive, independent of VEGF production. This correlated with increased vascular branching similar to that observed in isolated aortas and during development. Enhanced recovery was also associated with neovascular tuft formation, which showed defective NO production and increased eNOS-derived superoxide and NT levels.

Conclusions: In hyperoxia, reduced BH bioavailability causes overexpressed eNOS to become dysfunctional, exacerbating vaso-obliteration. In the proliferative phase, however, eNOS has important prorepair functions enhancing angiogenic growth potential and recovery in ischemia. © 2012 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a new approach for extracting stress intensity factors (SIFs) by the extended element-free Galerkin method, through a crack closure integral (CCI) scheme, is proposed. The CCI calculation is used in conjunction with a local smoothing technique to improve the accuracy of the computed SIFs in a number of case studies of linear elastic fracture mechanics. The cases involve problems of mixed-mode, curved crack and thermo-mechanical loading. The SIFs by CCI, displacement and stress methods are compared with those based on the M-integral technique reported in the literature. The proposed CCI method involves very simple relations, and still gives good accuracy. The convergence of the results is also examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare aerobic capacity, strength, flexibility, and activity level in extremely low birth weight (ELBW) adolescents at 17 years of age with term-born control subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors have much experience in developing mathematics skills of first-year engineering students and attempting to ensure a smooth transition from secondary school to university. Concerns exist due to there being flexibility in the choice of modules needed to obtain a secondary level (A-level) mathematics qualification. This qualification is based on some core (pure maths) modules and a selection from mechanics and statistics modules. A survey of aerospace and mechanical engineering students in Queen’s University Belfast revealed that a combination of both mechanics and statistics (the basic module in both) was by far the most popular choice and therefore only about one quarter of this cohort had studied mechanics beyond the basic module within school maths. Those students who studied the extra mechanics and who achieved top grades at school subsequently did better in two core, first-year engineering courses. However, students with a lower grade from school did not seem to gain any significant advantage in the first-year engineering courses despite having the extra mechanics background. This investigation ties in with ongoing and wider concerns with secondary level mathematics provision in the UK.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To estimate the prevalence of primary angle closure glaucoma (PACG) in European derived populations.

METHOD: Systematic review and modelling of PACG prevalence data from population studies. PACG was defined according to the ISGEO definition requiring structural and/or functional evidence of glaucomatous optic neuropathy. Prevalence estimates were applied to the 2010 United Nations projected population figures to estimate case numbers.

RESULTS: The prevalence of PACG in those 40 years or more is 0.4% (95% CI 0.3% to 0.5%). Age-specific prevalence values are 0.02% (CI 0.00 to 0.08) for those 40-49 years, 0.60% (0.27 to 1.00) for those 50-59 years, 0.20% (0.06 to 0.42) for those 60-69 years and 0.94% (0.63 to 1.35) for those 70 years and older. Three-quarters of all cases occur in female subjects (3.25 female to 1 male; CI 1.76 to 5.94).

CONCLUSION: This analysis provides a current evidence-based estimate of PACG prevalence in European derived populations and suggests there are 130,000 people in the UK, 1.60 million people in Europe and 581,000 people in the USA with PACG today. Accounting for ageing population structures, cases are predicted to increase by 19% in the UK, 9% in Europe and 18% in the USA within the next decade. PACG is more common than previously thought, and all primary glaucoma cases should be considered to be PACG until the anterior chamber angle is shown to be open on gonioscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study is to describe the ocular and demographic features of Caucasian patients newly presenting with primary angle closure glaucoma and the proportion of workload it represents at a tertiary university hospital glaucoma service. Methods: A retrospective case notes review was conducted for all Caucasian patients newly diagnosed with narrow angles, primary angle closure, acute primary angle closure and primary angle closure glaucoma that were seen over a period of 2 years. Demographic and ocular variables were compared and statistical analysis was carried out with the paired t -test and chi-squared test. Number of primary open angle closure glaucoma and acute angle closure cases were compared with total number of new referrals to the department, new patients diagnosed with glaucoma and population numbers for the North East of Scotland. Results: One hundred and four patients were analysed. Twenty-four (23.1%) had narrow angles, 30 (28.8%) had primary angle closure and 50 (48.1%) had primary angle closure glaucoma. Twelve (11.5%) presented with acute primary angle closure. There was no significant difference for gender, age, hypermetropia or visual acuity between groups. Primary angle closure glaucoma constituted 22.9% (50/128) of newly diagnosed glaucoma cases. Based on the 2001 Scotland census, the crude annual incidence of newly diagnosed primary angle closure glaucoma was estimated at 14.8 per 100000 and 3.6 per 100000 for acute primary angle closure in the over-45-year-old population. Conclusion: Our study confirms that primary angle closure glaucoma is uncommon in Caucasians, but not as rare as originally perceived as it makes up a fair proportion (22.9%) of glaucoma workload. © 2009 The Authors Journal Compilation © 2009 Royal Australian and New Zealand College of Ophthalmologists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.

OBJECTIVES: To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG.

SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012.

SELECTION CRITERIA: We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations, using laser peripheral iridoplasty to break acute crisis.

DATA COLLECTION AND ANALYSIS: No analysis was carried out as only one trial was included in the review.

MAIN RESULTS: We included one RCT with 158 participants. The trial reported laser peripheral iridoplasty as an adjunct to laser peripheral iridotomy compared to iridotomy alone. The authors report no superiority in using iridoplasty as an adjunct to iridotomy for IOP, number of medications or need for surgery.

AUTHORS' CONCLUSIONS: There is currently no strong evidence for laser peripheral iridoplasty's use in treating angle-closure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations. OBJECTIVES: To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles, PAC and PACG. SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library), MEDLINE, EMBASE and LILACS (Latin American and Caribbean Literature on Health Sciences). The databases were last searched on 11 February 2008. SELECTION CRITERIA: Only randomised controlled trials (RCTs) were eligible for inclusion in this review. Patients with narrow angles, PAC or PACG were eligible. Studies that included only patients with acute presentations, using laser peripheral iridoplasty to break acute crisis were excluded. DATA COLLECTION AND ANALYSIS: No analysis was carried out due to lack of trials. MAIN RESULTS: There were no RCTs assessing laser peripheral iridoplasty in the non-acute setting of angle-closure. AUTHORS' CONCLUSIONS: There is currently no strong evidence for laser peripheral iridoplasty's use in treating angle-closure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care.EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care.

METHODS/DESIGN: EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible.The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events.A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate.

TRIAL REGISTRATION: ISRCTN44464607.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Cases of angle-closure glaucoma in patients with familial exudative vitreoretinopathy have been reported secondary to neovascularization of the anterior segment. Cases secondary to nonneovascular mechanisms have not been previously reported. Methods: Two cases are presented of angle-closure glaucoma as a result of a nonneovascular mechanism. Results: Neovascularization was found to be a very unlikely explanation for the angle closure in these two cases. Conclusion: There may be an association between familial exudative vitreoretinopathy and angle-closure glaucoma as a direct result of a retrolental process or more likely a relative lens-iris pupillary block with a large lens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In specific solid-state materials, under the right conditions, collections of magnetic dipoles are known to spontaneously form into a variety of rather complex geometrical patterns, exemplified by vortex and skyrmion structures. While theoretically, similar patterns should be expected to form from electrical dipoles, they have not been clearly observed to date: the need for continued experimental exploration is therefore clear. In this Letter we report the discovery of a rather complex domain arrangement that has spontaneously formed along the edges of a thin single crystal ferroelectric sheet, due to surface-related depolarizing fields. Polarization patterns are such that nanoscale “flux-closure” loops are nested within a larger mesoscale flux closure object. Despite the orders of magnitude differences in size, the geometric forms of the dual-scale flux closure entities are rather similar.