282 resultados para Bone replacement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Interest in the prevention of osteoporosis is increasing and thus there is a need for an acceptable osteoporosis prevention programme in general practice. AIM. A study was undertaken to identify a cohort of middle-aged women attending a general practice who would be eligible for a longitudinal study looking at bone mineral density, osteoporosis and the effectiveness of hormone replacement therapy. This study aimed to describe the relationship between medical and lifestyle risk factors for osteoporosis and the initial bone density measurements in this group of women. METHOD. A health visitor administered a questionnaire to women aged between 48 and 52 years registered with a Belfast general practice. The main outcome measures were menopausal status, presence of medical and lifestyle risk factors and bone mineral density measurements. RESULTS. A total of 358 women our of 472 (76%) took part in the study which was conducted in 1991 and 1992. A highly significant difference was found between the mean bone mineral density of premenopausal, menopausal and postmenopausal women within the narrow study age range, postmenopausal women having the lowest bone mineral density. A significant relationship was found between body mass index and bone mineral density, a greater bone mineral density being found among women with a higher body mass index. Risk factors such as smoking and sedentary lifestyle were common (reported by approximately one third of respondents) but a poor relationship was found between these two and all the other risk factors and bone mineral density in this age group. CONCLUSION. Risk of osteoporosis cannot be identified by the presence of risk factors in women aged between 48 and 52 years. In terms of a current prevention strategy for general practice it would be better to take a population-based approach except for those women known to be at high risk of osteoporosis: women with early menopause or those who have had an oophorectomy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accurate models of cement and interface fatigue are essential if computationally assessing risk of aseptic loosening of cemented joint replacements is to become clinically relevant. A series of approaches will be presented that attempt to model several aspects of bone cement fatigue relevant to predicting cemented joint replacement failure. Failure models for homogeneous (bulk) bone cement and its interface with implant and host tissue are reviewed. Variability introduced by porosity and interaction between fatigue and creep are also considered. Finally, some current and potential future developments are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The initial composition of acrylic bone cement along with the mixing and delivery technique used can influence its final properties and therefore its clinical success in vivo. The polymerisation of acrylic bone cement is complex with a number of processes happening simultaneously. Acrylic bone cement mixing and delivery systems have undergone several design changes in their advancement, although the cement constituents themselves have remained unchanged since they were first used. This study was conducted to determine the factors that had the greatest effect on the final properties of acrylic bone cement using a pre-filled bone cement mixing and delivery system. A design of experiments (DoE) approach was used to determine the impact of the factors associated with this mixing and delivery method on the final properties of the cement produced. The DoE illustrated that all factors present within this study had a significant impact on the final properties of the cement. An optimum cement composition was hypothesised and tested. This optimum recipe produced cement with final mechanical and thermal properties within the clinical guidelines and stated by ISO 5833 (International Standard Organisation (ISO), International standard 5833: implants for surgery—acrylic resin cements, 2002), however the low setting times observed would not be clinically viable and could result in complications during the surgical technique. As a result further development would be required to improve the setting time of the cement in order for it to be deemed suitable for use in total joint replacement surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hip replacement surgery is amongst the most common orthopaedic operations performed in the UK. Aseptic loosening is responsible for 40% of hip revision procedures. Aseptic loosening is a result of cement mantle fatigue. The aim of the current study is to analyse the effect of nanoscale Graphene Oxide (GO) on the mechanical properties of orthopaedic bone cement. Study Design A experimental thermal and mechanical analysis was conducted in a laboratory set up conforming to international standards for bone cement testing according to ISO 5583. Testing was performed on control cement samples of Colacryl bone cement, and additional samples reinforced with variable wt% of Graphene Oxide containing composites – 0.1%, 0.25%, 0.5% and 1.0% GO loading. Pilot Data Porosity demonstrated a linear relationship with increasing wt% loading compared to control (p<0.001). Thermal characterisation demonstrated maximal temperature during polymerization, and generated exotherm were inversely proportional to w%t loading (p<0.05) Fatigue strength performed on the control and 0.1 and 0.25%wt loadings of GO demonstrate increased average cycles to failure compared to control specimens. A right shift of the Weibull curve was demonstrated for both wt% available currently. Logistic regression analysis for failure demonstrated significant increases in number of cycles to failure for both specimens compared to a control (p<0.001). Forward Plan Early results convey positive benefits at low wt% loadings of GO containing bone cement. Study completion and further analysis is required in order to elude to the optimum w%t of GO which conveys the greatest mechanical advantage.

Relevância:

20.00% 20.00%

Publicador: