28 resultados para Biometric menagerie


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM:

To utilise a novel method for making measurements in the anterior chamber in order to compare the anterior chamber angles of people of European, African, and east Asian descent aged 40 years and over.

METHODS:

A cross sectional study on 15 people of each sex from each decade from the 40s to the 70s, from each of three racial groups-black, white, and Chinese Singaporeans. Biometric gonioscopy (BG) utilises a slit lamp mounted reticule to make measurements from the apparent iris insertion to Schwalbe's line through a Goldmann one mirror goniolens. The main outcome measures were BG measurements of the anterior chamber angle as detailed above.

RESULTS:

There was no significant difference in angle measurement between black, white, and Chinese races in this study. However, at younger ages people of Chinese race appeared to have deeper angles than white or black people, whereas the angles of older Chinese were significantly narrower (p = 0.004 for the difference in slope of BG by age between Chinese and both black and white people).

CONCLUSION:

The failure to detect a difference in angle measurements between these groups was surprising, given the much higher prevalence of angle closure among Chinese. It appears that the overall apparent similarity of BG means between Chinese and Western populations may mask very different trends with age. The apparently more rapid decline in angle width measurements with age among Chinese may be due to the higher prevalence of cataract or "creeping angle closure." However, longitudinal inferences from cross sectional data are problematic, and this may represent a cohort phenomenon caused by the increasing prevalence of myopia in the younger Singaporean population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This theoretical paper attempts to define some of the key components and challenges required to create embodied conversational agents that can be genuinely interesting conversational partners. Wittgenstein's argument concerning talking lions emphasizes the importance of having a shared common ground as a basis for conversational interactions. Virtual bats suggests that-for some people at least-it is important that there be a feeling of authenticity concerning a subjectively experiencing entity that can convey what it is like to be that entity. Electric sheep reminds us of the importance of empathy in human conversational interaction and that we should provide a full communicative repertoire of both verbal and non-verbal components if we are to create genuinely engaging interactions. Also we may be making the task more difficult rather than easy if we leave out non-verbal aspects of communication. Finally, analogical peacocks highlights the importance of between minds alignment and establishes a longer term goal of being interesting, creative, and humorous if an embodied conversational agent is to be truly an engaging conversational partner. Some potential directions and solutions to addressing these issues are suggested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper investigates the problem of speaker identi-fication and verification in noisy conditions, assuming that speechsignals are corrupted by environmental noise, but knowledgeabout the noise characteristics is not available. This research ismotivated in part by the potential application of speaker recog-nition technologies on handheld devices or the Internet. Whilethe technologies promise an additional biometric layer of securityto protect the user, the practical implementation of such systemsfaces many challenges. One of these is environmental noise. Due tothe mobile nature of such systems, the noise sources can be highlytime-varying and potentially unknown. This raises the require-ment for noise robustness in the absence of information about thenoise. This paper describes a method that combines multicondi-tion model training and missing-feature theory to model noisewith unknown temporal-spectral characteristics. Multiconditiontraining is conducted using simulated noisy data with limitednoise variation, providing a “coarse” compensation for the noise,and missing-feature theory is applied to refine the compensationby ignoring noise variation outside the given training conditions,thereby reducing the training and testing mismatch. This paperis focused on several issues relating to the implementation of thenew model for real-world applications. These include the gener-ation of multicondition training data to model noisy speech, thecombination of different training data to optimize the recognitionperformance, and the reduction of the model’s complexity. Thenew algorithm was tested using two databases with simulated andrealistic noisy speech data. The first database is a redevelopmentof the TIMIT database by rerecording the data in the presence ofvarious noise types, used to test the model for speaker identifica-tion with a focus on the varieties of noise. The second database isa handheld-device database collected in realistic noisy conditions,used to further validate the model for real-world speaker verifica-tion. The new model is compared to baseline systems and is foundto achieve lower error rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For the first time in this paper the authors present results showing the effect of out of plane speaker head pose variation on a lip biometric based speaker verification system. Using appearance DCT based features, they adopt a Mutual Information analysis technique to highlight the class discriminant DCT components most robust to changes in out of plane pose. Experiments are conducted using the initial phase of a new multi view Audio-Visual database designed for research and development of pose-invariant speech and speaker recognition. They show that verification performance can be improved by substituting higher order horizontal DCT components for vertical, particularly in the case of a train/test pose angle mismatch.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the marine and terrestrial shell on Epipalaeolithic to Classical-period sites in the Cyrenaican coastlands, northeast Libya, with particular reference to the Haua Fteah, with parallel studies at a late-Roman farmstead and two small caves. Together they provide evidence for coastal and terrestrial environments and for the continued nutritional importance of gastropods to humans during the Holocene. Land snail evidence is consistent with regional vegetation in coastal Cyrenaica becoming increasingly open through the Holocene, as a result of some combination of climate change and human impact. Marine species suggest that the coastline near the Haua had been rocky throughout the Holocene. At Hagfet al-Gama, changing faunas provide evidence for sand encroachment onto a previously rocky shoreline in Hellenistic times. A biometric study of Osilinus turbinatus shows that in the archaeological sites these shells are systematically smaller than modern specimens, providing evidence for long-term dietary stress in the human populations around the Haua Fteah, with particularly severe stress in parts of the Epipalaeolithic. A biometric study of Patella spp. provided evidence for size selection, but also seems to show evidence for resource pressure. It is unlikely that variations in resource pressure seen in the mollusc biometrics are the result of climatic stress or natural ecological factors and explanations must be sought in society-environment dynamics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ear recognition, as a biometric, has several advantages. In particular, ears can be measured remotely and are also relatively static in size and structure for each individual. Unfortunately, at present, good recognition rates require controlled conditions. For commercial use, these systems need to be much more robust. In particular, ears have to be recognized from different angles ( poses), under different lighting conditions, and with different cameras. It must also be possible to distinguish ears from background clutter and identify them when partly occluded by hair, hats, or other objects. The purpose of this paper is to suggest how progress toward such robustness might be achieved through a technique that improves ear registration. The approach focuses on 2-D images, treating the ear as a planar surface that is registered to a gallery using a homography transform calculated from scale-invariant feature-transform feature matches. The feature matches reduce the gallery size and enable a precise ranking using a simple 2-D distance algorithm. Analysis on a range of data sets demonstrates the technique to be robust to background clutter, viewing angles up to +/- 13 degrees, and up to 18% occlusion. In addition, recognition remains accurate with masked ear images as small as 20 x 35 pixels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Significant recent progress has shown ear recognition to be a viable biometric. Good recognition rates have been demonstrated under controlled conditions, using manual registration or with specialised equipment. This paper describes a new technique which improves the robustness of ear registration and recognition, addressing issues of pose variation, background clutter and occlusion. By treating the ear as a planar surface and creating a homography transform using SIFT feature matches, ears can be registered accurately. The feature matches reduce the gallery size and enable a precise ranking using a simple 2D distance algorithm. When applied to the XM2VTS database it gives results comparable to PCA with manual registration. Further analysis on more challenging datasets demonstrates the technique to be robust to background clutter, viewing angles up to +/- 13 degrees and with over 20% occlusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To study the population distribution and longitudinal changes in anterior chamber angle width and its determinants among Chinese adults. Design: Prospective cohort, population-based study. Participants: Persons aged 35 years or more residing in Guangzhou, China, who had not previously undergone incisional or laser eye surgery. Methods: In December 2008 and December 2010, all subjects underwent automated keratometry, and a random 50% sample had anterior segment optical coherence tomography with measurement of angle-opening distance at 500 μm (AOD500), angle recess area (ARA), iris thickness at 750 μm (IT750), iris curvature, pupil diameter, corneal thickness, anterior chamber width (ACW), lens vault (LV), and lens thickness (LT) and measurement of axial length (AL) and anterior chamber depth (ACD) by partial coherence laser interferometry. Main Outcome Measures: Baseline and 2-year change in AOD500 and ARA in the right eye. Results: A total of 745 subjects were present for full biometric testing in both 2008 and 2010 (mean age at baseline, 52.2 years; standard deviation [SD], 11.5 years; 53.7% were female). Test completion rates in 2010 varied from 77.3% (AOD500: 576/745) to 100% (AL). Mean AOD500 decreased from 0.25 mm (SD, 0.13 mm) in 2008 to 0.21 mm (SD, 13 mm) in 2010 (difference, -0.04; 95% confidence interval [CI], -0.05 to -0.03). The ARA decreased from 21.5±3.73 10-2 mm2 to 21.0±3.64 10 -2 mm2 (difference, -0.46; 95% CI, -0.52 to -0.41). The decrease in both was most pronounced among younger subjects and those with baseline AOD500 in the widest quartile at baseline. The following baseline variables were significantly associated with a greater 2-year decrease in both AOD500 and ARA: deeper ACD, steeper iris curvature, smaller LV, greater ARA, and greater AOD500. By using simple regression models, we could explain 52% to 58% and 93% of variation in baseline AOD500 and ARA, respectively, but only 27% and 16% of variation in 2-year change in AOD500 and ARA, respectively. Conclusions: Younger persons and those with the least crowded anterior chambers at baseline have the largest 2-year decreases in AOD500 and ARA. The ability to predict change in angle width based on demographic and biometric factors is relatively poor, which may have implications for screening. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. © 2012 American Academy of Ophthalmology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Primary angle-closure glaucoma (PACG) is more prevalent among Chinese than whites. The authors tested the hypothesis that Chinese have shallower anterior chambers than do whites, a factor that may be related to PACG prevalence. METHODS: The authors compared anterior chamber depth, axial length, radius of corneal curvature, and refractive error among 531 Chinese, 170 whites, and 188 blacks older than 40 years of age using the same model of instruments and identical technique. RESULTS: Mean anterior chamber depth and axial length did not differ significantly for the three groups. Whites had a significantly higher prevalence of hyperopia > 2 diopters than did Chinese. Radius of corneal curvature was significantly smaller among Chinese than whites or blacks. CONCLUSIONS: These results suggest that Chinese do not differ on a population basis from other ethnic groups in many of the biometric risk factors known to be of importance for PACG. It will be necessary to identify other ocular biometric parameters to explain the excess burden of PACG among Chinese, which may improve the effectiveness of screening for this disease in all populations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND:

The prevalence of angle-closure glaucoma (ACG) is greater for Eskimos/Inuit than it is for any other ethnic group in the world. Although it has been suggested that this prevalence may be due to a population tendency toward shallower anterior chamber angles, available evidence for other populations such as Chinese with high rates of ACG has not consistently demonstrated such a tendency.

METHODS:

A reticule, slit-lamp, and standard Goldmann one-mirror goniolens were used to make measurements in the anterior chamber (AC) angle according to a previously reported protocol for biometric gonioscopy (BG) (Ophthalmology 1999;106:2161-7). Measurements were made in all four quadrants of one eye among 133 phakic Alaskan Eskimos aged 40 years and older. Automatic refraction, dilated examination of the anterior segment and optic nerve, and A-scan measurements of AC depth, lens thickness, and axial length were also carried out for all subjects.

RESULTS:

Both central and peripheral AC measurements for the Eskimo subjects were significantly lower than those previously reported by us for Chinese, blacks, and whites under the identical protocol. Eskimos also seemed to have somewhat more hyperopia. There were no differences in biometric measurements between men and women in this Eskimo population. Angle measurements by BG seemed to decline more rapidly over life among Eskimos and Chinese than blacks or whites. Although there was a significant apparent decrease in AC depth, increase in lens thickness, and increase in hyperopia with age among Eskimos, all of these trends seemed to reverse in the seventh decade and beyond.

CONCLUSIONS:

Eskimos do seem to have shallower ACs than do other racial groups. Measurements of the AC angle seem to decline more rapidly over life among Eskimos than among blacks or whites, a phenomenon also observed by us among Chinese, another group with high ACG prevalence. This apparent more rapid decline may be due to a cohort effect with higher prevalence of myopia and resulting wider angles among younger Eskimos and Chinese.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare anterior segment parameters between eyes of Chinese and Caucasians using anterior segment optical coherence tomography and to evaluate the association between these parameters and anterior chamber angle width between the two ethnic groups. METHODS: 60 Chinese and 60 Caucasians, 30 with open angles and 30 with narrow angles (defined as Shaffer grade < or =2 in > or =3 quadrants during dark room gonioscopy) in each group, were consecutively enrolled. One eye of each subject was randomly selected for imaging in a completely darkened room. Measurements, including anterior chamber depth (ACD), scleral spur-to-scleral spur distance (anterior chamber width (ACW)), anterior chamber angle width, iris convexity and iris thickness, were compared between the groups. The associations between angle opening distance and biometric measurements were evaluated with univariate and multivariate regression analyses. RESULTS: There were no differences in age, axial length, anterior chamber angle measurements, pupil diameter and iris convexity between Chinese and Caucasians in both open-angle and narrow-angle groups. However, the ACD and ACW were smaller and the iris was thicker in Chinese. In the multivariate analysis, the ACD was the most influential biometric parameter for angle opening distance in both Chinese and Caucasians. After adjusting the effects of axial length, age and sex, ACD and ACW were significantly smaller in Chinese. CONCLUSIONS: Chinese eyes had smaller ACD, smaller ACW and greater iris thickness than Caucasians. ACD was the most influential parameter in determining the angle width in both ethnic groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the rapid development of internet-of-things (IoT), face scrambling has been proposed for privacy protection during IoT-targeted image/video distribution. Consequently in these IoT applications, biometric verification needs to be carried out in the scrambled domain, presenting significant challenges in face recognition. Since face models become chaotic signals after scrambling/encryption, a typical solution is to utilize traditional data-driven face recognition algorithms. While chaotic pattern recognition is still a challenging task, in this paper we propose a new ensemble approach – Many-Kernel Random Discriminant Analysis (MK-RDA) to discover discriminative patterns from chaotic signals. We also incorporate a salience-aware strategy into the proposed ensemble method to handle chaotic facial patterns in the scrambled domain, where random selections of features are made on semantic components via salience modelling. In our experiments, the proposed MK-RDA was tested rigorously on three human face datasets: the ORL face dataset, the PIE face dataset and the PUBFIG wild face dataset. The experimental results successfully demonstrate that the proposed scheme can effectively handle chaotic signals and significantly improve the recognition accuracy, making our method a promising candidate for secure biometric verification in emerging IoT applications.